DS1249Y/AB 2048k Nonvolatile SRAM FEATURES PIN ASSIGNMENT
... 6. If the CE low transition occurs simultaneously with or latter than the WE low transition in Write Cycle 1, the output buffers remain in a high-impedance state during this period. 7. If the CE high transition occurs prior to or simultaneously with the WE high transition, the output buffers remain ...
... 6. If the CE low transition occurs simultaneously with or latter than the WE low transition in Write Cycle 1, the output buffers remain in a high-impedance state during this period. 7. If the CE high transition occurs prior to or simultaneously with the WE high transition, the output buffers remain ...
Texas Instruments
... Schmitt-trigger buffered inputs at the enable/clock lines of the ’S373 and ’S374 devices simplify system design as ac and dc noise rejection is improved by typically 400 mV due to the input hysteresis. A buffered output-control (OC) input can be used to place the eight outputs in either a normal log ...
... Schmitt-trigger buffered inputs at the enable/clock lines of the ’S373 and ’S374 devices simplify system design as ac and dc noise rejection is improved by typically 400 mV due to the input hysteresis. A buffered output-control (OC) input can be used to place the eight outputs in either a normal log ...
MPXM2051G, 0 to 10 kPa, Gauge Compensated Pressure Sensor
... licenses granted hereunder to design or fabricate any integrated circuits based on the ...
... licenses granted hereunder to design or fabricate any integrated circuits based on the ...
74LCX2244 Low Voltage Buffer/Line Driver with 5V Tolerant Inputs
... at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the Absolute Maximum Ratings. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Note 3: IO Absolute Maximum Rating must be observed. Note 4 ...
... at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the Absolute Maximum Ratings. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Note 3: IO Absolute Maximum Rating must be observed. Note 4 ...
Lab #5 Operational Amplifier
... determined by the positive and negative power supply voltages and some voltages drops internal to the OP-AMP. Outside the limits of the gain region, Vout stays fairly constant as Vin is changed; the regions of unchanging Vout values are called “saturation” regions, and there will be one for positive ...
... determined by the positive and negative power supply voltages and some voltages drops internal to the OP-AMP. Outside the limits of the gain region, Vout stays fairly constant as Vin is changed; the regions of unchanging Vout values are called “saturation” regions, and there will be one for positive ...
High Efficient Single Inductor Buck-Boost
... as a step-down converter (buck) when the input voltage is higher than the output voltage, and as a boost converter when the input voltage is lower than the output voltage. There is no mode of operation in which all 4 switches are permanently switching. Controlling the switches this way allows the co ...
... as a step-down converter (buck) when the input voltage is higher than the output voltage, and as a boost converter when the input voltage is lower than the output voltage. There is no mode of operation in which all 4 switches are permanently switching. Controlling the switches this way allows the co ...
Reduction of Harmonics Contained in the Input Power Supply
... B. Voltage source and current source inverters In accordance with the circuit electromagnetic processes, voltage source inverters (VSI) and current source inverters (CSI) are distinguished. A VSI is the most commonly used for high frequency induction heating system. The output signal of such inverte ...
... B. Voltage source and current source inverters In accordance with the circuit electromagnetic processes, voltage source inverters (VSI) and current source inverters (CSI) are distinguished. A VSI is the most commonly used for high frequency induction heating system. The output signal of such inverte ...
SN75ALS161 数据资料 dataSheet 下载
... The SN75ALS161 device features eight driver-receiver pairs connected in a front-to-back configuration to form input/output (I/O) ports at both the bus and terminal sides. The direction of data through these driver-receiver pairs is determined by the direction-control (DC) and talk-enable (TE) signal ...
... The SN75ALS161 device features eight driver-receiver pairs connected in a front-to-back configuration to form input/output (I/O) ports at both the bus and terminal sides. The direction of data through these driver-receiver pairs is determined by the direction-control (DC) and talk-enable (TE) signal ...
NBB-300 CASCADABLE BROADBAND GaAs MMIC AMPLIFIER DC TO 12GHz Features
... RF input pin. This pin is NOT internally DC blocked. A DC blocking capacitor, suitable for the frequency of operation, should be used in most applications. DC coupling of the input is not allowed, because this will override the internal feedback loop and cause temperature instability. Ground connect ...
... RF input pin. This pin is NOT internally DC blocked. A DC blocking capacitor, suitable for the frequency of operation, should be used in most applications. DC coupling of the input is not allowed, because this will override the internal feedback loop and cause temperature instability. Ground connect ...
the manual - TDK-Lambda Americas Inc.
... When shipped from the factory, each supply is configured for constant/voltage, constant/current, local programming, local sensing, single unit mode of operation. This normal mode of operation is usually used in most applications. All performance specifications unless otherwise stated are defined in ...
... When shipped from the factory, each supply is configured for constant/voltage, constant/current, local programming, local sensing, single unit mode of operation. This normal mode of operation is usually used in most applications. All performance specifications unless otherwise stated are defined in ...
LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits LF198/LF298/LF398, LF198A/LF398A
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
MAX774/MAX775/MAX776 -5V/-12V/-15V or Adjustable, High-Efficiency, Low I Inverting DC-to-DC Controllers
... current again reaches its limit. This cycle repeats until the output is in regulation. A benefit of this control scheme is that it is highly efficient over a wide range of input/output ratios and load currents. Additionally, PFM converters do not operate with constant-frequency switching, and have r ...
... current again reaches its limit. This cycle repeats until the output is in regulation. A benefit of this control scheme is that it is highly efficient over a wide range of input/output ratios and load currents. Additionally, PFM converters do not operate with constant-frequency switching, and have r ...
AN2528
... Base drive circuit design Let's have a closer look at the very simple base drive network used in this application. Normally in applications such SMPS, where the load is variable, the collector current varies as well. It is very important to provide a base current to the device that is correlated wit ...
... Base drive circuit design Let's have a closer look at the very simple base drive network used in this application. Normally in applications such SMPS, where the load is variable, the collector current varies as well. It is very important to provide a base current to the device that is correlated wit ...
Design Approach to Light-Load Effective Power Supply Utilizing the
... protection is activated allowing the converter to ride through a short line drop-out. Timer Based Overcurrent Protection: The devices NCP1244/46 offer the overcurrent protection which is activated when the voltage at CS pin is above the internal threshold of 0.7 V (typ.) for a longer time than the o ...
... protection is activated allowing the converter to ride through a short line drop-out. Timer Based Overcurrent Protection: The devices NCP1244/46 offer the overcurrent protection which is activated when the voltage at CS pin is above the internal threshold of 0.7 V (typ.) for a longer time than the o ...
LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
... Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures a ...
EVAL-ADE7752AEBZ 数据手册DataSheet 下载
... that is, when the phase angle between the voltage and the current signals is greater than 90°. This output is not latched and is reset when positive power is once again detected. See the Negative Power Information section. Analog Inputs for Current Channel. This channel is intended for use with the ...
... that is, when the phase angle between the voltage and the current signals is greater than 90°. This output is not latched and is reset when positive power is once again detected. See the Negative Power Information section. Analog Inputs for Current Channel. This channel is intended for use with the ...
KNW013-020 - GE Industrial Solutions
... voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module’s output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: ...
... voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module’s output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: ...