MAX2470/MAX2471 10MHz to 500MHz VCO Buffer Amplifiers with Differential Outputs General Description
... The MAX2470/MAX2471 are flexible, low-cost, highreverse-isolation buffer amplifiers for applications with discrete and module-based VCO designs. Both feature differential 50Ω outputs for driving a single differential (balanced) load or two separate single-ended (unbalanced) 50Ω loads. The MAX2470 of ...
... The MAX2470/MAX2471 are flexible, low-cost, highreverse-isolation buffer amplifiers for applications with discrete and module-based VCO designs. Both feature differential 50Ω outputs for driving a single differential (balanced) load or two separate single-ended (unbalanced) 50Ω loads. The MAX2470 of ...
Experiments for First Year Electrical Engg Lab
... phenomenon of falling back of flux density while demagnetization cycle is called hysteresis. Hence due to this effect, when current becomes exactly zero, there remains some magnetism associated with a coil and hence the flux density .The core does not get completely demagnetized though current throu ...
... phenomenon of falling back of flux density while demagnetization cycle is called hysteresis. Hence due to this effect, when current becomes exactly zero, there remains some magnetism associated with a coil and hence the flux density .The core does not get completely demagnetized though current throu ...
Efficient Excitation Signals for the Fast Impedance Spectroscopy
... As shown in Section IV, the decaying part of the magnitude spectrum can be effectively covered with a multisine excitation with properly chosen decay rate β of amplitudes and optimal initial phases Φ (i). To obtain almost flat spectrum of the response signal the first excitation frequency in the amp ...
... As shown in Section IV, the decaying part of the magnitude spectrum can be effectively covered with a multisine excitation with properly chosen decay rate β of amplitudes and optimal initial phases Φ (i). To obtain almost flat spectrum of the response signal the first excitation frequency in the amp ...
HMC449LC3B
... good system noise performance. The HMC449LC3B eliminates the need for wire bonding, allowing the use of surface mount manufacturing techniques. ...
... good system noise performance. The HMC449LC3B eliminates the need for wire bonding, allowing the use of surface mount manufacturing techniques. ...
The No-Nonsense Technician Class License Study Guide
... lightning protection, battery safety, electrical code compliance • Antenna installation, tower safety, overhead power lines • RF hazards, radiation exposure, RF heating hazards, proximity to antennas, recognized safe power levels, hand held safety, exposure to others Radio waves, propagation, and an ...
... lightning protection, battery safety, electrical code compliance • Antenna installation, tower safety, overhead power lines • RF hazards, radiation exposure, RF heating hazards, proximity to antennas, recognized safe power levels, hand held safety, exposure to others Radio waves, propagation, and an ...
Ch.17
... the n’th harmonic of f(t). • If n is odd, the function is called the odd harmonic. • If n is even, the function is called the even harmonic. • The equation on the last slide is called the trigonometric Fourier series of f(t). • The constants an and bn are called the Fourier coefficients. ...
... the n’th harmonic of f(t). • If n is odd, the function is called the odd harmonic. • If n is even, the function is called the even harmonic. • The equation on the last slide is called the trigonometric Fourier series of f(t). • The constants an and bn are called the Fourier coefficients. ...
Beyond Design: Effective Routing of Multiple
... We’ve covered differential clock and strobe routing in previous columns, but let’s look at address routing. Fly-by topology—as used in double data rate design—uses a daisy-chain or multi-drop topology on address, command and control signals. Fly-by topology reduces simultaneous switching noise (SSN) ...
... We’ve covered differential clock and strobe routing in previous columns, but let’s look at address routing. Fly-by topology—as used in double data rate design—uses a daisy-chain or multi-drop topology on address, command and control signals. Fly-by topology reduces simultaneous switching noise (SSN) ...
Difet OPA627 OPA637 Precision High-Speed
... and drift, so many circuits will not require external adjustment. Figure 3 shows the optional connection of an external potentiometer to adjust offset voltage. This adjustment should not be used to compensate for offsets created elsewhere in a system (such as in later amplification stages or in an A ...
... and drift, so many circuits will not require external adjustment. Figure 3 shows the optional connection of an external potentiometer to adjust offset voltage. This adjustment should not be used to compensate for offsets created elsewhere in a system (such as in later amplification stages or in an A ...
Optimized Resonant Harmonic Filters
... parameters makes the best selection of parameters by trial and error methods very difficult. In order to solve complex ...
... parameters makes the best selection of parameters by trial and error methods very difficult. In order to solve complex ...
Improved Power Quality Based Electronic Ballast for a Fluorescent
... and simulation of this topology are carried out in MatlabSimulink environment for a fluorescent lamp fed from 220V, 50Hz ac mains. The power quality indices are estimated such as total harmonic distortion of ac mains current (THDi), power factor (PF) and crest factor (CF). Keywords–Power factor corr ...
... and simulation of this topology are carried out in MatlabSimulink environment for a fluorescent lamp fed from 220V, 50Hz ac mains. The power quality indices are estimated such as total harmonic distortion of ac mains current (THDi), power factor (PF) and crest factor (CF). Keywords–Power factor corr ...