OP275 - Analog Devices
... OP275 is the fastest of any standard audio amplifier. Best of all, this low noise and high speed are accomplished using less than 5 mA of supply current, lower than any standard audio amplifier. ...
... OP275 is the fastest of any standard audio amplifier. Best of all, this low noise and high speed are accomplished using less than 5 mA of supply current, lower than any standard audio amplifier. ...
AC Series and Parallel Circuits
... 1. Introduce the use of the oscilloscope for measuring current through the branches of a circuit 2. Introduce more complex AC series/parallel circuits II. Equipment. Keysight 34450A Digital Multimeter (DMM) Oscilloscope, Function Generator 100, 1500-Ω resistor, 47 mH inductor, 0.1-μF capacitor III. ...
... 1. Introduce the use of the oscilloscope for measuring current through the branches of a circuit 2. Introduce more complex AC series/parallel circuits II. Equipment. Keysight 34450A Digital Multimeter (DMM) Oscilloscope, Function Generator 100, 1500-Ω resistor, 47 mH inductor, 0.1-μF capacitor III. ...
CM8870/70C CMOS Integrated DTMF Receiver
... contents of the output latch are made available on the 4-bit output bus by raising the three-state control input (TOE) to a logic high. The steering circuit works in reverse to validate the interdigit pause between signals. Thus, as well as rejecting signals too short to be considered valid, the rec ...
... contents of the output latch are made available on the 4-bit output bus by raising the three-state control input (TOE) to a logic high. The steering circuit works in reverse to validate the interdigit pause between signals. Thus, as well as rejecting signals too short to be considered valid, the rec ...
AD8200 数据手册DataSheet 下载
... By attenuating voltages at Pins 1 and 8, the amplifier inputs are held within the power supply range, even if Pin 1 and Pin 8 input levels exceed the supply, or fall below common (ground.) The input network also attenuates normal (differential) mode voltages. RC and RG form an attenuator that scales ...
... By attenuating voltages at Pins 1 and 8, the amplifier inputs are held within the power supply range, even if Pin 1 and Pin 8 input levels exceed the supply, or fall below common (ground.) The input network also attenuates normal (differential) mode voltages. RC and RG form an attenuator that scales ...
EUP3406 1.5MHz, 600mA Synchronous Step-Down Converter
... The EUP3406 is a constant frequency, current mode, PWM step-down converter. The device integrates a main switch and a synchronous rectifier for high efficiency. The 2.5V to 5.5V input voltage range makes the EUP3406 ideal for powering portable equipment that runs from a single cell Lithium-Ion (Li+) ...
... The EUP3406 is a constant frequency, current mode, PWM step-down converter. The device integrates a main switch and a synchronous rectifier for high efficiency. The 2.5V to 5.5V input voltage range makes the EUP3406 ideal for powering portable equipment that runs from a single cell Lithium-Ion (Li+) ...
MAX2470/MAX2471 10MHz to 500MHz VCO Buffer Amplifiers with Differential Outputs General Description
... The MAX2470 and MAX2471 incorporate fully differential output stages capable of driving an AC-coupled 100Ω differential load or two AC-coupled 50Ω singleended loads. This is ideal for applications that require the oscillator to drive two application circuits (e.g. mixer and PLL) simultaneously. The ...
... The MAX2470 and MAX2471 incorporate fully differential output stages capable of driving an AC-coupled 100Ω differential load or two AC-coupled 50Ω singleended loads. This is ideal for applications that require the oscillator to drive two application circuits (e.g. mixer and PLL) simultaneously. The ...
5.50" 140mm 1.00", 25.4mm 1.25" 31.8mm 0.30" 7.6mm 0.95" 24.1
... All external connections must be SELV (Safety Extra Low Voltage). ...
... All external connections must be SELV (Safety Extra Low Voltage). ...
installation operation and maintenance siltronix model 1011d
... For 12-14 volt DC operation in mobile installations, it will be necessary to use the Siltronix 14A Converter. The Model 14A D.C. Converter attaches to the rear of the Model 1011D transceiver and converts it to 12-14 volts D.C. input. The 14A D.C. Converter is for normal negative ground systems. Two ...
... For 12-14 volt DC operation in mobile installations, it will be necessary to use the Siltronix 14A Converter. The Model 14A D.C. Converter attaches to the rear of the Model 1011D transceiver and converts it to 12-14 volts D.C. input. The 14A D.C. Converter is for normal negative ground systems. Two ...
Sniper
... 1:1 cable to your ILDA standard output of your software, and start doing your laser shows. It is so easy. No mounting, no screwing, no shuttering. The cable from the computer to the Sniper can be almost as long as you want - depending on the architecture of your computer interface card. For example: ...
... 1:1 cable to your ILDA standard output of your software, and start doing your laser shows. It is so easy. No mounting, no screwing, no shuttering. The cable from the computer to the Sniper can be almost as long as you want - depending on the architecture of your computer interface card. For example: ...
DC to 2.0 GHz Multiplier ADL5391
... core is fundamentally asymmetric with respect to the X and Y inputs, leading to relative amplitude and timing misalignments that are problematic at high frequencies. The new multiplier core eliminates these misalignments by offering symmetric signal paths for both X and Y inputs. The Z input allows ...
... core is fundamentally asymmetric with respect to the X and Y inputs, leading to relative amplitude and timing misalignments that are problematic at high frequencies. The new multiplier core eliminates these misalignments by offering symmetric signal paths for both X and Y inputs. The Z input allows ...
galvanic coupling - emc of ele - Journal of electrical engineering
... conductor - higher frequencies The problem analysis will be done for the case of two electric circuits interconnection, the scheme of which is shown in figure Fig. 2. Let the upper circuit be supplied by a DC voltage source with the value U1 = 5 V. As interface conductor the same cable as in the pre ...
... conductor - higher frequencies The problem analysis will be done for the case of two electric circuits interconnection, the scheme of which is shown in figure Fig. 2. Let the upper circuit be supplied by a DC voltage source with the value U1 = 5 V. As interface conductor the same cable as in the pre ...
Feedback - Jack Ou
... 1. The frequency is low enough that C2 does not load the output node and CGS behaves as an open circuit. 2. gmro is sufficiently large 3. Bias of the gate is not shown! ...
... 1. The frequency is low enough that C2 does not load the output node and CGS behaves as an open circuit. 2. gmro is sufficiently large 3. Bias of the gate is not shown! ...
TD-1435 - IHS.com
... [1] The accuracy specification applies for any combination of operating temperature and voltage. [2] The accuracy will not be affected by power interruptions up to 1 millisecond, spaced at least 10 milliseconds apart. Transient and power loss specifications are based on a maximum duty cycle of 1/50. ...
... [1] The accuracy specification applies for any combination of operating temperature and voltage. [2] The accuracy will not be affected by power interruptions up to 1 millisecond, spaced at least 10 milliseconds apart. Transient and power loss specifications are based on a maximum duty cycle of 1/50. ...
HXM-1 Hx Series Microphone Preamplifier User`s Guide
... Microphone Pad: this switch inserts a 20 dB pad in front of the Jensen microphone transformer; it is used to prevent overload distortion (red LED above) when the gain control cannot. it also prevents the transformer from saturating. Overload is indicated by the red LED above the switch. Phantom: thi ...
... Microphone Pad: this switch inserts a 20 dB pad in front of the Jensen microphone transformer; it is used to prevent overload distortion (red LED above) when the gain control cannot. it also prevents the transformer from saturating. Overload is indicated by the red LED above the switch. Phantom: thi ...