Remote Sense - Vishay Precision Group
... another pair of wires would be connected between the excitation terminals on the transducer and the remote sense terminals at the instrumentation. The remote sensing circuit in the instrumentation is designed to continuously monitor the excitation voltage actually present at the transducer and, depe ...
... another pair of wires would be connected between the excitation terminals on the transducer and the remote sense terminals at the instrumentation. The remote sensing circuit in the instrumentation is designed to continuously monitor the excitation voltage actually present at the transducer and, depe ...
EM powerLED PRO DIM C 45 W
... According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance m ...
... According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance m ...
Zahn, M., Transient Drift Dominated Unipolar Conduction Between Concentric Cylinders and Spheres, IEEE Transactions on Electrical Insulation, EI-11, 150-157, 1976
... and semiconductors. For the case of unipolar ion conduction in a one-dimensional planar geometry, recent results have obtained generalized solutions for the transient time and spatial responses of the electric-field and space-charge distributions and for the terminal current-voltage (I-V) characteri ...
... and semiconductors. For the case of unipolar ion conduction in a one-dimensional planar geometry, recent results have obtained generalized solutions for the transient time and spatial responses of the electric-field and space-charge distributions and for the terminal current-voltage (I-V) characteri ...
AP7335 300mA, LOW QUIESCENT CURRENT, FAST TRANSIENT LOW DROPOUT LINEAR REGULATOR
... The output capacitor is required to stabilize and improve the transient response of the LDO. The AP7335 is stable with very small ceramic output capacitors. Using a ceramic capacitor value that is at least 1μF with ESR > 15mΩ on the output ensures stability. Higher capacitance values help to improve ...
... The output capacitor is required to stabilize and improve the transient response of the LDO. The AP7335 is stable with very small ceramic output capacitors. Using a ceramic capacitor value that is at least 1μF with ESR > 15mΩ on the output ensures stability. Higher capacitance values help to improve ...
BD8963EFJ
... decreases efficiency. The inductor must be selected to allow a sufficient margin with which the peak current may not exceed its current rating. If VCC=5V, VOUT=1.1V, f=1MHz, ΔIL=0.2A x 3A=0.6A, for example, (BD8963EFJ) 5 1.11.1 1.43 1.5 H L 0.6 5 1M Note: Select the inductor with ...
... decreases efficiency. The inductor must be selected to allow a sufficient margin with which the peak current may not exceed its current rating. If VCC=5V, VOUT=1.1V, f=1MHz, ΔIL=0.2A x 3A=0.6A, for example, (BD8963EFJ) 5 1.11.1 1.43 1.5 H L 0.6 5 1M Note: Select the inductor with ...
4.5 V to 42 V Input, 5 A, Step Down DC
... adjusted using a resistor to ground connected to the RT/CLK pin. The device has an internal phase-locked loop (PLL) connected to the RT/CLK pin that will synchronize the power switch turn on to a falling edge of an external clock signal. The TPS54540-Q1 has a default input start-up voltage of approx ...
... adjusted using a resistor to ground connected to the RT/CLK pin. The device has an internal phase-locked loop (PLL) connected to the RT/CLK pin that will synchronize the power switch turn on to a falling edge of an external clock signal. The TPS54540-Q1 has a default input start-up voltage of approx ...
a AN-574 APPLICATION NOTE
... To select the F1-4 frequency for Equation 1, see the AD7751 data sheet—Selecting a Frequency for an Energy Meter Application. From Tables V and VI in the AD7751 data sheet it can be seen that the best choice of frequency for a meter with IMAX = 40 A is 3.4 Hz (F2). This frequency selection is made b ...
... To select the F1-4 frequency for Equation 1, see the AD7751 data sheet—Selecting a Frequency for an Energy Meter Application. From Tables V and VI in the AD7751 data sheet it can be seen that the best choice of frequency for a meter with IMAX = 40 A is 3.4 Hz (F2). This frequency selection is made b ...
Analogue-Theory-and-Circuit-Analysis
... Consider this circuit for discharging a capacitor – At t = 0, VC = V – From Kirchhoff’s voltage law ...
... Consider this circuit for discharging a capacitor – At t = 0, VC = V – From Kirchhoff’s voltage law ...
measurement of phase angles with the help of the cathode ray tube
... for this voltage drop is represented in fig. 8a. by the battery shown jn series with R. With.a given gridbias the correet position of the operating point is thus obtained only when the , gri~ current has a certain mean value -{g. The yalue "" of ig, h_oweve;r, depends closely upon the height' of the ...
... for this voltage drop is represented in fig. 8a. by the battery shown jn series with R. With.a given gridbias the correet position of the operating point is thus obtained only when the , gri~ current has a certain mean value -{g. The yalue "" of ig, h_oweve;r, depends closely upon the height' of the ...
AD781
... 3.... Intermodulation terms are those for which m or n is not equal to zero. For example, the second order terms are (fa+fb) and (fa–fb), and the third order terms are (2fa+fb), (2fa–fb), (fa+2fb) and (fa–2fb). The IMD products are expressed as the decibel ratio of the rms sum of the measured input ...
... 3.... Intermodulation terms are those for which m or n is not equal to zero. For example, the second order terms are (fa+fb) and (fa–fb), and the third order terms are (2fa+fb), (2fa–fb), (fa+2fb) and (fa–2fb). The IMD products are expressed as the decibel ratio of the rms sum of the measured input ...
MAX3273 +3.3V, 2.5Gbps Low-Power Laser Driver General Description Features
... An APC failure flag (FAIL) is asserted low when the bias current can no longer be adjusted to achieve the desired average optical power. APC closed-loop operation requires the user to set three currents with external resistors connected between ground and BIASMAX, MODSET, and APCSET (see Figure 3). ...
... An APC failure flag (FAIL) is asserted low when the bias current can no longer be adjusted to achieve the desired average optical power. APC closed-loop operation requires the user to set three currents with external resistors connected between ground and BIASMAX, MODSET, and APCSET (see Figure 3). ...
Just like capacitors, we have types of resistors
... This functions depends on how it is connected in the circuit. In this work, we are going to dwell much on it’s function as a switch. The output squared wave signal from the timer is fed to the base of the PNP transistor this signal suffers several venations at the function of the transistor. Finall ...
... This functions depends on how it is connected in the circuit. In this work, we are going to dwell much on it’s function as a switch. The output squared wave signal from the timer is fed to the base of the PNP transistor this signal suffers several venations at the function of the transistor. Finall ...