• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Control principles of micro-source inverters used in microgrid
Control principles of micro-source inverters used in microgrid

LTC5542 - 1.6GHz to 2.7GHz High Dynamic Range Downconverting Mixer.
LTC5542 - 1.6GHz to 2.7GHz High Dynamic Range Downconverting Mixer.

WARNING! - AR - RF Microwave Instrumentation
WARNING! - AR - RF Microwave Instrumentation

... The type N RF input connector is located on the rear panel. The RF input is fed to the input connector on the solid state preamp. The solid state preamp's output drives a voltage-controlled variable attenuator (E20325) which permits control of the amplifier’s output power from the control module. Th ...
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-

... power, known as Maximum Power Point Tracking (MPPT) control and typically, the MPPT control can be enhanced by integrating a boost stage between the PV panels and the inverter shown in Fig. 2. Moreover, the injected grid current should have less harmonic components, which is referred as Total Harmon ...
An Octave-Range, Watt-Level, Fully
An Octave-Range, Watt-Level, Fully

... output power range without any need for RF gain control, as we will explain in Section V. Therefore, simple digital gates such as inverters can be used to buffer the LO resulting in a small die area and low power consumption. In general, different BB input signals can be applied to different power m ...
TPA0211 2-W Mono Audio Power Amplifier
TPA0211 2-W Mono Audio Power Amplifier

... Equation 2 is reconfigured as equation 5. ...
Low-Complexity MPPT Technique Exploiting the PV Module MPP
Low-Complexity MPPT Technique Exploiting the PV Module MPP

A 35 fJ 10b 160 MS/s Pipelined-SAR ADC with Decoupled Flip
A 35 fJ 10b 160 MS/s Pipelined-SAR ADC with Decoupled Flip

HMC985 数据资料DataSheet下载
HMC985 数据资料DataSheet下载

... The mounting surface should be clean and flat. Eutectic Die Attach: A 80/20 gold tin preform is recommended with a work surface temperature of 255 °C and a tool temperature of 265 °C. When hot 90/10 nitrogen/hydrogen gas is applied, tool tip temperature should be 290 °C. DO NOT expose the chip to a ...
Enhancement of Power Quality in Renewable Energy System by
Enhancement of Power Quality in Renewable Energy System by

... of these two dc capacitors must be controlled to be equal. The control for balancing these two dc capacitors is very important in controlling the diode-clamped multilevel inverter, and it is very hard under the light load. If the five-level output voltage is expected, extra two diodes and four power ...
AD636 Low Level, True RMS-to
AD636 Low Level, True RMS-to

... The AD636 is a low power monolithic IC that performs true rms-to-dc conversion on low level signals. It offers performance that is comparable or superior to that of hybrid and modular converters costing much more. The AD636 is specified for a signal range of 0 mV to 200 mV rms. Crest factors up to 6 ...
Precision Logarithmic and Log Ratio Amplifier
Precision Logarithmic and Log Ratio Amplifier

7I49 MANUAL
7I49 MANUAL

High-Performance Adaptive Perturb and Observe MPPT Technique
High-Performance Adaptive Perturb and Observe MPPT Technique

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... Fig. 3 Schematic and layout diagram for 2-way WPD has been designed. The result of this simulation contains graphs of the return loss, insertion loss and isolation of the 2-way WPD has been designed as depicted in Fig. 4. For the 2-way WPD, all the ports have excellent well matched with excellent re ...
Isolation Fault Troubleshooting
Isolation Fault Troubleshooting

Understanding Absolute Pressure Sensors Technical Note
Understanding Absolute Pressure Sensors Technical Note

Steady-State Analysis of Single Phase A.C. Circuit
Steady-State Analysis of Single Phase A.C. Circuit

... Arsonval, Weston, iron vane, electrodynamometer) will work so long as they have been calibrated in RMS figures. Because the mechanical inertia and dampening effects of an electromechanical meter movement makes the deflection of the needle naturally proportional to the average value of the AC, not th ...
Design and Implementation of Dynamic Voltage Restorer for Voltage Sag Mitigation
Design and Implementation of Dynamic Voltage Restorer for Voltage Sag Mitigation

... The common causes of voltage sag are faults or short circuit in the system, starting of large loads and faulty wiring. This will lead to increase in both production and financial loss for industries. Therefore, it is vital to mitigate voltage sag. Two main characteristics that explain the voltage sa ...
ii. direct calculation of power loss in radial distribution systems
ii. direct calculation of power loss in radial distribution systems

... The power loss on the DTs makes up an appreciable portion of a utility’s overall loss. According to [3], the DTs account for 26% of transmission and distribution losses and 41% of distribution and sub transmission losses [4]. In [5], it was estimated that the DTs occupy 55% of total distribution los ...
Total Power Advantage Using Spartan-7 FPGAs
Total Power Advantage Using Spartan-7 FPGAs

ELEC 7770: Advanced VLSI Design Spring 2010 Radio Frequency (RF) Testing
ELEC 7770: Advanced VLSI Design Spring 2010 Radio Frequency (RF) Testing

...  Show that for a nonlinear device with a single frequency input of amplitude A, the nth harmonic component in the output always contains a term proportional to An. ...
High Voltage Power
High Voltage Power

TRANSIENT VOLTAGE SUPPRESSOR COMPLIANCE TO
TRANSIENT VOLTAGE SUPPRESSOR COMPLIANCE TO

Performance of Line-start Permanent Magnet Synchronous Motor
Performance of Line-start Permanent Magnet Synchronous Motor

< 1 ... 63 64 65 66 67 68 69 70 71 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report