• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... (6) The ISO must make a decision on its approval and notify the legal owner in writing of the decision no later than ninety (90) days after the date of receiving the submission set out in subsection 5(5). (7) The legal owner of a generating unit without the capability to meet the reactive power capa ...
2011_6_june_Griffith_CSISCS_slides
2011_6_june_Griffith_CSISCS_slides

230-V, 400-W, 92% High Efficiency Battery Charger With PFC and
230-V, 400-W, 92% High Efficiency Battery Charger With PFC and

... (CV/CC) feedback is achieved using the TL103W, which has an integrated dual op-amp and a 2.5-V reference. The system is designed to meet below 200 mW of standby power when no battery is connected. This goal is achieved by using a simple logic circuit that disables PFC and LLC power stages when batte ...
chapter - 1
chapter - 1

... Voltage is proportional to the magnetic flux in the power system element. Most of the Power System elements are reactive in nature. They absorb / generate reactive power depending on system loading conditions. The balance in reactive power availability and requirement at a node indicates steady volt ...
Self-Paced Study Guide in Exponentials and Logarithms March 31, 2011 1
Self-Paced Study Guide in Exponentials and Logarithms March 31, 2011 1

... each topic area. A numbering system facilitates easy tracking of subject material. For example, in the topic area Algebra, the subtopic Linear Equations is numbered with 2.3. Problems and self-evaluations are categorized using this numbering system. When using the Self-Paced Review, it is important ...
Aalborg Universitet Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive
Aalborg Universitet Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive

... faults, negative sequence current is also injected to suppress the negative sequence voltage. Besides, LVRT in wind farms usually has the objective of injecting balanced three-phase currents or nullifying the 100Hz power oscillations by controlling the grid side converter (GSC) [13]−[15]. In [14], a ...
ferromanganese smelting
ferromanganese smelting

3720 ACM IC Installation Instructions
3720 ACM IC Installation Instructions

... EPROM The 3720 ACM uses an on-board microprocessor to perform all its measurement and calculation tasks. The microprocessor operates by following the program of instructions stored in an integrated circuit called an EPROM (Erasable Programmable Read Only Memory). This I.C. is either a 28-pin or 32-p ...
The DatasheetArchive - Datasheet Search Engine
The DatasheetArchive - Datasheet Search Engine

Optimal placement of shunt connected facts device in a series long
Optimal placement of shunt connected facts device in a series long

... In general, the addition of an (interconnecting) line can result in increase of power flow in a line (while decreasing the power flow in some other line). This is an interesting feature of AC transmission lines and not usually well understood (in the context of restructuring). In general, it can be ...
Robust Digital Control for Interleaved PFC Boost Converter Using Approximate 2DOF
Robust Digital Control for Interleaved PFC Boost Converter Using Approximate 2DOF

Basic Rack Power Distribution Unit AP9559
Basic Rack Power Distribution Unit AP9559

... • Do not handle any kind of metallic connector before the power has been removed. • Use one hand, whenever possible, to connect or disconnect signal cables to avoid a possible shock from touching two surfaces with different grounds. • This unit does not have any user-serviceable parts. Repairs are t ...
VU Meters to Loudness Meter
VU Meters to Loudness Meter

... Hearing frequency characteristic is approximated by K-filter being composed of Pre-filter *1 and RLB*2 , as shown in above. ...
Speaker: Fabien Pascal, Institut d`Electronique du Sud (IES
Speaker: Fabien Pascal, Institut d`Electronique du Sud (IES

... many semiconductors devices. LF noise spectroscopy is a non destructive characterization technique. LF noise analysis is based on the measurement of current or voltage fluctuations around an average value (biasing point). Experimentally, the current or voltage spectral density in a device is measure ...
EE 1071216
EE 1071216

... device “Power quality is described as the deviation of voltage, current from its ideal waveforms. It refers to a wide variety of electromagnetic phenomena such as voltage sag, flicker, harmonic distortion transients etc.. that characterize the voltage and current at a given time and at a given locat ...
Harmonic Minimization in the Operation of Static VAR
Harmonic Minimization in the Operation of Static VAR

Modelling and Simulation of Step-Up and Step
Modelling and Simulation of Step-Up and Step

... Key-Words: Step-up and step-down transformers, Power model and current. there is a relationship of proportionality between the two. If the model of transformer includes internal impedance, the voltage across the alternator stator is calculated from other variables, including voltage busbar HT, as wi ...
RF5626 Proposed
RF5626 Proposed

... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
AN3410
AN3410

... Constant-power V-I curve and linear approximation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Linear approximation error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Input current compensated for 3 levels of output power . . ...
Millimeter-Wave CMOS Power Amplifiers With High Output Power
Millimeter-Wave CMOS Power Amplifiers With High Output Power

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

gmesprit user guide
gmesprit user guide

... to the desired power level, the Green READY lamp will illuminate indicating that the unit is ready to fire. Note: If the unit is subjected to rapid operation over extended periods, it may automatically go into an overheat condition. In this condition, the Green READY lamp will illuminate to indicate ...
LTC5541 - 1.3GHz to 2.3GHz High Dynamic Range Downconverting Mixer.
LTC5541 - 1.3GHz to 2.3GHz High Dynamic Range Downconverting Mixer.

Loudness, Its Definition, Measurement and
Loudness, Its Definition, Measurement and

... and depend upon the experience, the auditory accumulated it was evident that such a basis for acuity, and the customs of the persons using defining loudnessmust be abandoned. them. If loudness depended only upon the inIn 1924 in a paper by Steinberg and Fletcher1 tensity of the soundwave producingth ...
Single-stage, universal-input ac/dc led driver with current
Single-stage, universal-input ac/dc led driver with current

< 1 ... 57 58 59 60 61 62 63 64 65 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report