• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
KU Band Up Convertor - C-DOT Centre for Development of Telematics
KU Band Up Convertor - C-DOT Centre for Development of Telematics

Solaira SHP High Power Control - Mor Electric Heating Assoc., Inc.
Solaira SHP High Power Control - Mor Electric Heating Assoc., Inc.

... please contact Solaira directly for cost and availability. SIZING CONSIDERATIONS SOLAIRA SHP HIGH POWER CONTROLS Model are designed for use on variable resistance loads such as quartz/tungsten emitters and tubes. Size units by actual load amps and not kW. 1. Always use maximum possible load current ...
Amplifiers
Amplifiers

Slide 1
Slide 1

... Current de-facto standard  Most publications today are algorithms for the efficient switching between states using OSPM ...
“Fuzzy Logic Speed Controllers Using FPGA Technique For Three
“Fuzzy Logic Speed Controllers Using FPGA Technique For Three

... Syllabus Instructor: Room: Telephone: E-mail: Web-page: ...
TIA Contribution Ref Codec, Loudness Ratings, Handsfree
TIA Contribution Ref Codec, Loudness Ratings, Handsfree

... Send frequency response (Send sensitivity) is the ratio of the voltage output of the reference codec to the sound pressure at the Mouth Reference Point (MRP) for each frequency or frequency band (Fi) as shown in the equation below: ...
Sunmodule Plus 285W mono
Sunmodule Plus 285W mono

... Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than o ...
Overcurrent Protection and Voltage Sag Coordination in Systems
Overcurrent Protection and Voltage Sag Coordination in Systems

SolarWorld Sunmodule Plus 285 watt mono solar panel data sheet
SolarWorld Sunmodule Plus 285 watt mono solar panel data sheet

... Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than o ...
0.1% of the reading + 1 digit) DC Amps
0.1% of the reading + 1 digit) DC Amps

... Lets say, in a circuit, we are reading a 0.812 volts using the 2V range setting The accuracy is (0.1% of the reading + 1 digit) So the accuracy is  0.000812 V ...
Stakeholder Comment and Rationale Form  AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft

... New Proposed New ISO Rules Section 304.4 Version 2.0 sets out requirements regarding adjustments to the set point of the automatic voltage regulator or voltage regulating system or the on-load tap changer, and indicates exceptions. ...
dicodes E-Cigarette Control Unit “Dani Basic”
dicodes E-Cigarette Control Unit “Dani Basic”

... must not be supplied with voltages more than 4.5V. The adjustments and handling is intuitive by pressing the button short term or for a longer interval. With the button actuated for more than 0.25 sec., power is applied to the heating winding, until the button is released or the maximum vapor time o ...
Spencer Streeter - University of Utah College of Engineering
Spencer Streeter - University of Utah College of Engineering

SK0-004-04
SK0-004-04

Types of electric vehicle chargers
Types of electric vehicle chargers

Power Factor Correction Panel
Power Factor Correction Panel

No Slide Title
No Slide Title

Meter Accuracy
Meter Accuracy

Monitoring Relays 1-Phase Voltage selection Type DUA55
Monitoring Relays 1-Phase Voltage selection Type DUA55

Standing Waves - Oregon State EECS
Standing Waves - Oregon State EECS

revelite al technical spec sheet
revelite al technical spec sheet

Will Reducing The Line Voltage Save Energy?
Will Reducing The Line Voltage Save Energy?

Film capacitors - PowerFactor Correction - MMI7000
Film capacitors - PowerFactor Correction - MMI7000

Document
Document

... with parasitic capacitors and time mismatch is derived with the state-space averaging method. The derived loop-gain functions are verified with time-domain small signal injection simulation and measurement, with a good match between the analytical and experimental results. Existing system:  Three l ...
Improving the Power Factor of Isolated Flyback Converters for
Improving the Power Factor of Isolated Flyback Converters for

< 1 ... 264 265 266 267 268 269 270 271 272 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report