• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
High Switching Frequency for Sinusoidal Pulse Width Modulation
High Switching Frequency for Sinusoidal Pulse Width Modulation

Methodology for Effective Hierarchical Verification of Low
Methodology for Effective Hierarchical Verification of Low

...  In a flatten design, theoretically level shifters and isolation cells can be inserted at anywhere in the design. Therefore, it is always possible to implement the design without any LS/ISO/Logic violations for a given PST.  However, in a hierarchical flow, because some sub-blocks are not allowed ...
datasheet - Global Test Supply
datasheet - Global Test Supply

The HV 2/4 high-voltage power supply module
The HV 2/4 high-voltage power supply module

... value. For the PF- version the minimum value of B’ is 0, i.e. the polarity of the output cannot change if (B - A) would mathematically yield a negative value. This option allows keeping the potential difference between the high voltage outputs constant (corresponding to the B set value) while the po ...
chapter3
chapter3

Experiment 1.
Experiment 1.

The experience of the Qualistar,
The experience of the Qualistar,

... Global THD and per phase on U, I, V and VA in % and RMS value, phase offset of harmonics. They offer the expert mode for the Harmonics function. These two instruments can be used to analyse the influence of the harmonics on heating of the neutral or on rotating machines. ...
SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd
SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd

TekScope THS700 Series Handheld Digital Oscillscopes
TekScope THS700 Series Handheld Digital Oscillscopes

24129 Create and measure automotive series
24129 Create and measure automotive series

... Values of power are calculated for an automotive circuit using correct formula and showing correct multiples and sub-multiples of the unit in accordance with textbook descriptions. Range ...
guitar amplifier
guitar amplifier

... 2: OVERDRIVE LEVEL: Use this control to increase the output volume and add “crunch” to your sound. This control is only active when the Overdrive Gain control (#3) is turned on. For more information please see the “Getting Your Sound” section on the previous page. 3: OVERDRIVE GAIN: Use this control ...
360AMX AC Power Source Datasheet
360AMX AC Power Source Datasheet

Application to Connect FIT Project to Bluewater Power Distribution
Application to Connect FIT Project to Bluewater Power Distribution

Owner`s Guide for the Bass Amplifier
Owner`s Guide for the Bass Amplifier

... from the signal that was present at the Preamp Out jack (16). This can be used as a post-Master (10) patch point. ...
PDF/186 kB - Bachmann electronic GmbH
PDF/186 kB - Bachmann electronic GmbH

... Grid Measurement Modules ...
FPD750 0.5W POWER pHEMT Features Product Description
FPD750 0.5W POWER pHEMT Features Product Description

... applied to the attachment surface uniformly and sparingly to avoid encroachment of epoxy on to the top face of the die, and ideally should not exceed half the chip height. For automated dispense Ablestick LMISR4 is recommended, and for manual dispense Ablestick 84-1 LMI or 84-1 LMIT are recommended. ...
ADXL202 - Senior Design
ADXL202 - Senior Design

ADXL202 - Senior Design
ADXL202 - Senior Design

IS1954 How Much Electrical Power Do You Need?
IS1954 How Much Electrical Power Do You Need?

File - Mohammed Al Nasser e
File - Mohammed Al Nasser e

Examination of the Change in the Power Factor Due to Loading Effect
Examination of the Change in the Power Factor Due to Loading Effect

... between sources and loads [2]. This current and voltages are sensed by using instrument transformers like current transformer and voltage transformer. Poor power factor costs our community in increased electricity charges and unnecessary effect in the system and poor power quality [3]. The actual am ...
AD45048: Rail-to-Rail Upstream ADSL Line Driver Data Sheet
AD45048: Rail-to-Rail Upstream ADSL Line Driver Data Sheet

Using WebRelayTM for Remote Reboot
Using WebRelayTM for Remote Reboot

Plena All-in-One Unit - Bosch Security Systems
Plena All-in-One Unit - Bosch Security Systems

Multimode Power Controllers for Three Phase Matrix
Multimode Power Controllers for Three Phase Matrix

... Q power flow can be effectively controlled using the MCUPFC and one of the three controllers. The nonlinear DPC methodology show no steady-state errors, no cross coupling, insensitivity to non-modeled dynamics, fast response times, and low THD, whereas the simpler PI linear P and Q power controllers ...
< 1 ... 243 244 245 246 247 248 249 250 251 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report