• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Assessment to Study of Voltage Unbalance Effects about Efficiency
Assessment to Study of Voltage Unbalance Effects about Efficiency

... the voltage angle. Likewise, these authors show that the derating factor given by the NEMA standard is insufficient to evaluate the effects of unbalance voltage on the motor, because it is based only in NEMA definition. However, these authors do not give a mathematical relation that may be used to e ...
Control of Electric Power Systems
Control of Electric Power Systems

auxiliary winding - Powertech Engines Inc
auxiliary winding - Powertech Engines Inc

... The auxiliary winding is another winding inside the stator slots. It's electrically independent from the main stator winding and its function is to supply an independent source of power to the AVR for a constant voltage. There are two big advantages when a generator is supplied with the aux winding: ...
Measurement and Calibrate for Analog Quantity
Measurement and Calibrate for Analog Quantity

MX Series data sheet - AMETEK Programmable Power
MX Series data sheet - AMETEK Programmable Power

... Series programmable controller is capable of generating harmonic waveforms to test for harmonics susceptibility. The Windows Graphical User Interface program can be used to define harmonic waveforms by specifying amplitude and phase for up to 50 harmonics. The waveform data points are generated and ...
Product Data SheetRev A
Product Data SheetRev A

... wideband performance as well as supporting 40 V operation. The TGA2976-SM operates from 0.1 - 3.0 GHz and provides greater than 10 W of saturated output power with greater than 13 dB of large signal gain and greater than 38% power-added efficiency. The TGA2976-SM is available in a low-cost, surface ...
Power Amplifier Circuits
Power Amplifier Circuits

Using a Phase-Shifted Full-Bridge Topology in
Using a Phase-Shifted Full-Bridge Topology in

Pinnacle® Plus+ Pulsed-DC Power Supplies
Pinnacle® Plus+ Pulsed-DC Power Supplies

HVDC AND POWER ELECTRONICS INTERNATIONAL
HVDC AND POWER ELECTRONICS INTERNATIONAL

Synchronous Generator Line Synchronization
Synchronous Generator Line Synchronization

... Using the information from (5-9), the circuit phasors can be plotted for constant power as the field current is varied. This is shown for three values of field current in Figure 3. Note that the synchronous generator can operate with a leading power factor, unity power factor, or lagging power facto ...
P85324 E50 MULTICANDELA SPEAKER SPEAKERSTROBE
P85324 E50 MULTICANDELA SPEAKER SPEAKERSTROBE

... NOTE: Graph does not apply to 1575W models. NOTE: The speaker strobe appliances must be set to the desired dBA sound output level before they are installed. This is done by properly inserting jumper plugs in accordance with these instructions. WARNING: Incorrect settings will result in improper perf ...
2.1 Introduction - Fred. Olsen Energy
2.1 Introduction - Fred. Olsen Energy

A Novel Measurement System for the Common-Mode
A Novel Measurement System for the Common-Mode

AiT Semiconductor Inc. DESCRIPTION FEATURES APPLICATION
AiT Semiconductor Inc. DESCRIPTION FEATURES APPLICATION

... CV/I =1000uF x 3.5V/ 0.2uA = 17500 sec = 4.8 hrs Example 2. Two-battery power supply with VCC-GND capacitance equals 1000uF. If the voltage of each exhausted battery to be replaced is 1.0V on average then the voltage on the 1000uF capacitor is 2.0V. The voltage allowed to drop is 2.0V-0.5V=1.5V. Wit ...
full abstracts in word format
full abstracts in word format

... transmission based on Voltage Source Converters (VSCs). The VSC based HVDC installations has several advantages compared to conventional HVDC such as, independent control of active and reactive power, dynamic voltage support at the converter bus for enhancing stability possibility to feed to weak AC ...
Brochure
Brochure

... number of solutions ...
Analog Devices HMC903 Datasheet
Analog Devices HMC903 Datasheet

Series 70 ePODs: Type-N - LayerZero Power Systems, Inc
Series 70 ePODs: Type-N - LayerZero Power Systems, Inc

Voltage Sag Mitigation in Distribution Line using DSTATCOM
Voltage Sag Mitigation in Distribution Line using DSTATCOM

... The aim of the control scheme is to maintain constant voltage magnitude at the point where a sensitive load is connected, under system disturbances. The control system only measures the r.m.s voltage at the load point, i.e., no reactive power measurements are required .This control is divided into t ...
TTR®300 Series 3-Phase Transformer Turns Ratio Test Sets
TTR®300 Series 3-Phase Transformer Turns Ratio Test Sets

Power Quality Improvement in 3P4W System Using Unified Power
Power Quality Improvement in 3P4W System Using Unified Power

Power Flow Control and Voltage Profile Improvement Using Unified
Power Flow Control and Voltage Profile Improvement Using Unified

... were solved for the power flow solutions. Over the years, several approaches have been put forward to solve for the power flow equations. Early approaches were based on the loop equations and methods using Gauss-type solutions. This method was laborious because the network loops has to be specified ...
AG4201218222
AG4201218222

... utilization of the existing transmission systems with the help of new technologies so called Flexible AC Transmission Systems (FACTS) devices[3]. Here we are using Unified Power Flow Controller (UPFC) for ATC enhancement in between the areas, Since UPFC is a multifunctional FACTS device which has th ...
AD8398A 数据手册DataSheet 下载
AD8398A 数据手册DataSheet 下载

... POWER SUPPLY BYPASSING The AD8398A typically operates on ±6 V or +12 V supplies. Power the AD8398A circuit with a well-regulated, properly decoupled power supply. To minimize supply voltage ripple and power dissipation, use high quality capacitors with low equivalent series resistance (ESR), such as ...
< 1 ... 162 163 164 165 166 167 168 169 170 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report