• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Amplifier Terms Defined (AN-60-038)
Amplifier Terms Defined (AN-60-038)

... A. Yes, but it's not as simple as merely connecting the two inputs and the two outputs in parallel. It involves judicious use of power hybrids with proper amplitude and phase balance and power levels, as well as amplifiers well matched for gain and phase characteristics. Examples are the HELA-10 and ...
AN91 - Low Cost Coupling Methods for RF Power Detectors Replace Directional Couplers
AN91 - Low Cost Coupling Methods for RF Power Detectors Replace Directional Couplers

International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.9, pp. 1988-1993
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.9, pp. 1988-1993

... fixed compensation, resonance with source impedance and the difficulty in tuning time dependence of filter parameters have ignited the need for active and hybrid filters. The rating of active filters is reduced through augmenting them with passive filters to form hybrid filters, which reduce overall ...
The Intersil ICL7107 is high performance Included are seven
The Intersil ICL7107 is high performance Included are seven

... up to de-integrate a positive signal but lose charge (decrease voltage) when called up to deintegrate a negative input signal. This difference in reference for positive or negative input voltage will give a roll-over error. However, by selecting the reference capacitor such that it is large enough i ...
Inverter Power Stage Connected with PV-Grid
Inverter Power Stage Connected with PV-Grid

review_transmission_media_v1
review_transmission_media_v1

... • inverse of dielectric resistance between shield & conductor • results from small current leakage between them R = DC resistance of wire, proportional to length & thickness C = wire’s inherent capacitance L = wire’s inherent inductance ...
AC Theory - Department of Electrical Engineering
AC Theory - Department of Electrical Engineering

... It is usual to express Z in cartesian form in terms of R and X, and Y in terms of G and B. The real part of the impedance Z is resistive and is usually denoted by a resistance R, while the imaginary part of the impedance Z is called a reactance and is usually denoted by a reactance X. It can be seen ...
Power System
Power System

... Write Short notes on Maintenance of gas insulated substation a) Where Gas Insulated Substation is preferred b) What are the Comparisons of Gas Insulated Substation over Air Insulated What are the Merits and Demerits of SF6 Gas Insulated Substation Where and Why Gas Insulated Substations are Used Des ...
lecture 1 power quality
lecture 1 power quality

... Power quality becoming important to electricity consumers at all levels of usage. The end-users are now more concerned to protect their sensitive loads from power quality disturbances by installing protection equipment. ...
Electronic Devices Conventional Current Version Thomas L. Floyd
Electronic Devices Conventional Current Version Thomas L. Floyd

Lecture 7: Power Outline Power and Energy
Lecture 7: Power Outline Power and Energy

SCP6844-GL-##H - Sumitomo Electric Europe Ltd
SCP6844-GL-##H - Sumitomo Electric Europe Ltd

... 1) Tx Fault is an open collector output that shall be pulled up with a 4.7k - 10kΩ resistor on the host board. Pull up voltage between 2.0V and VccT+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. Tx Fault is asserted when bias current of laser exceeds t ...
Communication BVI-3 Une nouvelle methode pour !`analyse par
Communication BVI-3 Une nouvelle methode pour !`analyse par

... at a distance equal to 1r 1 Ac from the previous one, where r 1 is the radial distance from the latter node to the conductor centre and 1 is a parameter that controls the mesh growth pattern. A value of .t•l. 5 was found to result, generally, in good element shapes throughout the whole mesh, for pro ...
Aalborg Universitet Agent-based Distributed Unbalance Compensation for Optimal Power Quality in
Aalborg Universitet Agent-based Distributed Unbalance Compensation for Optimal Power Quality in

... compensating current. The even compensation is enabled by implementing an additional droop loop for negative sequence power sharing. In [10], the inverter-interfaced DGs are used for compensating the unbalances in point of common coupling (PCC). Each DG injects zero and negative sequence current tri ...
1. introduction - Scientific Bulletin of Electrical Engineering Faculty
1. introduction - Scientific Bulletin of Electrical Engineering Faculty

... are independent, the resulting interference current can be computed by applying the law of quadratic summation of non-correlated signals. If the disturbing level of an overhead line can be measured by means of the radiated radiofrequency field, the estimation of each component’s contribution (e.g. i ...
Total active power is defined as
Total active power is defined as

embedded controlled multi level voltage source inverter based
embedded controlled multi level voltage source inverter based

O A
O A

... and 1.25 where 1.15 service factors and 1.25 relay pickup setting, then the rated current is equal 280A this value approximated to the closed standard of CT ratio which equal 300\5 The calibration of relay 51 is: X=(195)(5)/300 = 3.25 A, it is approximated to closed tap where L =3.5 . The relay pick ...
MeasurementsG11ES
MeasurementsG11ES

... Therefore, R=V/I, and so, in order to measure resistance, a meter measures both the current and the voltage. One of the basic components of electrical circuits is the resistor which is shown in fig 2.11. This component is designed to provide a specific Fig 2.11 ...
single phase multi string five level inverter for distributed energy
single phase multi string five level inverter for distributed energy

... instead of using conventional full bridge inverter, a five level inverter with six power switches are introduced to improve the power conversion. The five level inverter is operated with reduced voltage stress, switching loss and harmonics. MATLAB simulation validates the performance of the proposed ...
Pearl Street Lab
Pearl Street Lab

... 4. Adjust the variac so that the measured brightness is between 34 and 38 units (these are arbitrary units of brightness) above the background value of the sensor. The non-zero background value is caused by background light in the room. 5. When you are ready to take data, verify that the brightness ...
MANUAL FOR ULTRA GUARD 430-LED OPTION
MANUAL FOR ULTRA GUARD 430-LED OPTION

Wide Input Voltage Range High Power Density High
Wide Input Voltage Range High Power Density High

Dynamic power management for embedded system
Dynamic power management for embedded system

... Automatic selection of operating points as devices change states is a central feature of DPM. Embedded systems may not have a BIOS or machine abstraction layer to insulate the operating system from low-level device and power management. The most aggressive power management strategies will also re ...
pedal power - Voodoo Lab
pedal power - Voodoo Lab

... The Voodoo Lab Pedal Power 2 Plus is the finest power supply available for guitar effects. It’s eight 9V outputs will power any type of battery operated effect. Each output is completely isolated, short-circuit protected, highly filtered and regulated. This insures reliable operation, free of hum an ...
< 1 ... 154 155 156 157 158 159 160 161 162 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report