• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A Higher Voltage Multilevel Inverter with Reduced Number of Power
A Higher Voltage Multilevel Inverter with Reduced Number of Power

... the ability of its modulation. So, if an error occurs in one of the blocks, it can replace or fix by using a control system, but there are some disadvantages such as high number of dc voltage sources and power electronic ...
Medium Voltage Variable Frequency Drives
Medium Voltage Variable Frequency Drives

... was developed into practical products. Because of thyristor structure, GTOs can have blocking voltages as high as 6kV and can turn off as much as several thousand amperes of current. The turn-off gain is around 3 to 4; that is, it takes 1/4 to 1/3 of the anode current as a negative current in the ga ...
Virtex-5 FPGA System Power Design Considerations
Virtex-5 FPGA System Power Design Considerations

... In the past, ASSPs and ASICs often consumed the majority of power in system power budgets. With the increase in FPGA performance, functions, and density, FPGA power consumption is now a key design consideration and must meet certain industry standards for maximum power allowed. For example, the comm ...
POWER METER PW3336/PW3337
POWER METER PW3336/PW3337

... Connect multiple instruments to synchronize their operation, including display updates, data updates, and start of integration. Measure all data with simultaneous parallel processing, including RMS values, mean values, fundamental wave components, THD, and harmonic components. Wide frequency band fr ...
Fuel Cell Specification Notes
Fuel Cell Specification Notes

Catalogue PFC Parts and Trays
Catalogue PFC Parts and Trays

... Power factor correction: why? ...
using intelligent power modules - Mitsubishi Electric Corporation
using intelligent power modules - Mitsubishi Electric Corporation

Sizing gensets for motor starting
Sizing gensets for motor starting

Using the i.MX28 Power Management Unit and Battery Charger
Using the i.MX28 Power Management Unit and Battery Charger

Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

... protection using separate and independent current and control circuits. Normal and alternate preferred power conductors located between the Fermi 3 UATs and RATs and the 345 kV switchyard buses are protected by dual high-speed current differential schemes. The 345 kV switchyard circuit breakers are ...
Need to fix broken links [quote author=Mike Sokol link=topic
Need to fix broken links [quote author=Mike Sokol link=topic

PDF
PDF

... converter commutation count, and hence its switching losses. Also presented in Section IV is two sets of higher level control schemes with the first used for controlling one set of three-phase outputs so as to compensate for harmonic currents, reactive power flow and three-phase unbalance caused by ...
Micrologic P fonctionnement
Micrologic P fonctionnement

... Relays with temporary latching ...
TPS2375-77 - Texas Instruments
TPS2375-77 - Texas Instruments

... inrush current limit control current into the pin. The PG circuit monitors the RTN voltage and also uses it as the return for the PG pin pulldown transistor. The internal MOSFET body diode clamps VSS to RTN when voltage is present between VDD and RTN and the PoE input is not present. PG: This pin go ...
Energy Management System
Energy Management System

AAT4672 数据资料DataSheet下载
AAT4672 数据资料DataSheet下载

... higher than the under voltage lockout (UVLO) threshold, and MAIN pin voltage is greater than the AUX pin voltage plus 200mV. The AUX pin connects to the OUT pin only when the MAIN pin voltage drops 0.2V below the AUX pin voltage and the AUX pin voltage is greater than the UVLO threshold. If both inp ...
Generator Performance Standards
Generator Performance Standards

AN10909 Low V transistors in medium power load switch applications
AN10909 Low V transistors in medium power load switch applications

... for the design. They define the performance of especially TR1 where most power losses occur. The control switch TR2 typically is a general-purpose transistor like a BC847 or PMBT3904, and has to deliver currents in the range of a few up to 100 mA as base drive for TR1. Typical values for hFE are aro ...
LTC4415 - Dual 4A Ideal Diodes with Adjustable Current Limit
LTC4415 - Dual 4A Ideal Diodes with Adjustable Current Limit

... Note 4: The LTC4415 includes overtemperature protection that is intended to protect the device during momentary overload conditions. Junction temperature will exceed 125°C when overtemperature protection is active. Continuous operation above the specified maximum operating junction temperature may i ...
Energy Harvesting With Microbial Fuel Cell and Power Management
Energy Harvesting With Microbial Fuel Cell and Power Management

SKY77764 数据资料DataSheet下载
SKY77764 数据资料DataSheet下载

... match into a 50-ohm load, realized off-chip within the module package, optimizes efficiency and power performance. The SKY77764 is manufactured with Skyworks' InGaP GaAs Heterojunction Bipolar Transistor (HBT) process which provides for all positive voltage DC supply operation and maintains high eff ...
Features General Description
Features General Description

... line. The peak-charging effect, which occurs on the input filter capacitor in these supplies, causes brief high-amplitude pulses of current to flow from the power line, rather than a sinusoidal current inphase with the line voltage. Such supplies present a power factor to the line of less than one (i. ...
Soft-Switching Full-Bridge PWM DC–DC
Soft-Switching Full-Bridge PWM DC–DC

AND8353 - ON Semiconductor
AND8353 - ON Semiconductor

... delivering maximum power. The output voltage increases and over stresses the components. The NCP1607 incorporates two features to protect the application if FB is floating. The internal pull-down resistor, RFB, ensures that the FB pin is pulled low if it is floating. Additionally, an internal timer ...
Keysight Technologies Right Load Switching and Simulation Design
Keysight Technologies Right Load Switching and Simulation Design

... either a high or low side driver. Each output is connected with different load and the test will either be sequential or concurrent. At lower power levels, these can usually be managed with general purpose switches. However, when it comes to higher power levels of currents over 5 amps, such switchin ...
< 1 ... 30 31 32 33 34 35 36 37 38 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report