TDC-UC-330-DX - T-Opto
... Thank you for your interest in T-OptoTM! We have the largest selection of new-style LEDs and power supplies for the general illumination market. Our products add a whole new dimension to your lighting design toolbox and are applicable to all types of high-reliability, high-efficiency, high-brightnes ...
... Thank you for your interest in T-OptoTM! We have the largest selection of new-style LEDs and power supplies for the general illumination market. Our products add a whole new dimension to your lighting design toolbox and are applicable to all types of high-reliability, high-efficiency, high-brightnes ...
AT ATX - WordPress.com
... ATX Advanced Technology eXtended This enables different power supplies to be interchangeable with different components inside the computer. ATX power supplies also are designed to turn on and off using a signal from the motherboard, and provide support for modern functions such as the standby ...
... ATX Advanced Technology eXtended This enables different power supplies to be interchangeable with different components inside the computer. ATX power supplies also are designed to turn on and off using a signal from the motherboard, and provide support for modern functions such as the standby ...
3–16 power factor
... Power Factor is the ratio of active power (watts) to apparent power (VA) expressed as a percent that does not exceed 100%. Power Factor is a form of measurement of how far the voltage and current are out-of-phase with each other. In an ac circuit that supplies power to resistive loads such as incand ...
... Power Factor is the ratio of active power (watts) to apparent power (VA) expressed as a percent that does not exceed 100%. Power Factor is a form of measurement of how far the voltage and current are out-of-phase with each other. In an ac circuit that supplies power to resistive loads such as incand ...
Motion Along a Straight Line at Constant
... minimise energy losses due to heat during electricity distribution ...
... minimise energy losses due to heat during electricity distribution ...
High current double halfbridge tester
... A special version of our double halfbridge tester is capable to provide 100 A forward current sequentially and up to 6 x 15 A loading current (1 sec impulse in avalanche, power control possible) simultaneously for both halfbridges with selectable voltages for 14 V, 28 V and 42 V devices. ...
... A special version of our double halfbridge tester is capable to provide 100 A forward current sequentially and up to 6 x 15 A loading current (1 sec impulse in avalanche, power control possible) simultaneously for both halfbridges with selectable voltages for 14 V, 28 V and 42 V devices. ...
Project Title: Active Power Filter
... The rapid increase in use of electronic equipment in recent years imposes nonlinear loads on the ac main that draws a reactive and harmonic current in addition to the active current. The reactive and harmonic current lead to low efficiency, harmful electromagnetic interference to neighboring applian ...
... The rapid increase in use of electronic equipment in recent years imposes nonlinear loads on the ac main that draws a reactive and harmonic current in addition to the active current. The reactive and harmonic current lead to low efficiency, harmful electromagnetic interference to neighboring applian ...
AS 90941 Student 3 Parallel circuit is a circuit where 2 or more path
... many appliances will mean the current also increases due to more appliances pulling out certain amount of amps from the power source which can then produce heat in the wires and burn the insulator of the wire and burn the house down but normally we would have a fuse to prevent this from happening. ( ...
... many appliances will mean the current also increases due to more appliances pulling out certain amount of amps from the power source which can then produce heat in the wires and burn the insulator of the wire and burn the house down but normally we would have a fuse to prevent this from happening. ( ...
Power Factor - radio works rf consulting
... Power factor is a calculation representing the relationship of "real" power (kw) which performs useful work in turning a motor, to "apparent" power (kva) which magnetizes motor and transformer coils. Motor loads frequently adversely affect the power factor of a circuit, usually from oversized or lig ...
... Power factor is a calculation representing the relationship of "real" power (kw) which performs useful work in turning a motor, to "apparent" power (kva) which magnetizes motor and transformer coils. Motor loads frequently adversely affect the power factor of a circuit, usually from oversized or lig ...
Homework 4 ECE 207 – Electrical Engineering Due: 9/27/2012 A
... 1. A three-phase, 10 hp, 208 V, 50 Hz, 4 pole, Y-connected induction motor delivers rated output power at a slip of 2%. Determine: a. Synchronous speed b. Rotor speed c. Synchronous speed and rotor speed, if the motor had 2 poles 2. A three-phase, 25 hp, 230 V, 60 Hz induction motor draws 60 A from ...
... 1. A three-phase, 10 hp, 208 V, 50 Hz, 4 pole, Y-connected induction motor delivers rated output power at a slip of 2%. Determine: a. Synchronous speed b. Rotor speed c. Synchronous speed and rotor speed, if the motor had 2 poles 2. A three-phase, 25 hp, 230 V, 60 Hz induction motor draws 60 A from ...
Portable measuring equipment for grid analysis
... card and output in Excel format or printed out. The Windows-based software allows a wide range of functions to be programmed and the data to be evaluated graphically and numerically. The measured results are assigned a date stamp for superior transparency. The meter also calculates the required corr ...
... card and output in Excel format or printed out. The Windows-based software allows a wide range of functions to be programmed and the data to be evaluated graphically and numerically. The measured results are assigned a date stamp for superior transparency. The meter also calculates the required corr ...
PowerSecure
... Specialized control algorithms are deployed with high efficiency and high speed computation. Fast Harmonic and Power Factor Compensation is therefore effectively done in all three phases with remarkable precision, therefore reducing facility damages inflicted by dangerous harmonic current and low po ...
... Specialized control algorithms are deployed with high efficiency and high speed computation. Fast Harmonic and Power Factor Compensation is therefore effectively done in all three phases with remarkable precision, therefore reducing facility damages inflicted by dangerous harmonic current and low po ...
- Krest Technology
... This project proposes power factor correction using push pull quasi resonant converter. A boost power factor corrector converts universal AC input voltage into regulated DC output voltage. This converter is composed of transition mode boost type power factor corrector and a coupled inductor. By inte ...
... This project proposes power factor correction using push pull quasi resonant converter. A boost power factor corrector converts universal AC input voltage into regulated DC output voltage. This converter is composed of transition mode boost type power factor corrector and a coupled inductor. By inte ...
SET-276. Power factor correction and alerts through the
... those companies who do not demonstrate clear energy efficiency use. You will find this charge itemized on electricity bill. Reactive power charges can be made significantly smaller by the introduction of Power Factor Correction Capacitors which is a widely recognized method of reducing an electrical ...
... those companies who do not demonstrate clear energy efficiency use. You will find this charge itemized on electricity bill. Reactive power charges can be made significantly smaller by the introduction of Power Factor Correction Capacitors which is a widely recognized method of reducing an electrical ...
Assiut university researches Ramptime Current
... inductance at the ac output and a dc-bus capacitor. The CCVSI is operated to directly control the ac source current to be sinusoidal and in phase with the ac source voltage. The inverter switching is controlled using ramptime current control being based on the concept of zero average current error ( ...
... inductance at the ac output and a dc-bus capacitor. The CCVSI is operated to directly control the ac source current to be sinusoidal and in phase with the ac source voltage. The inverter switching is controlled using ramptime current control being based on the concept of zero average current error ( ...
Power factor
In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.