• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FPF2310/12/13/13L Dual-Output Adjustable Current Limit Switch FPF23 1
FPF2310/12/13/13L Dual-Output Adjustable Current Limit Switch FPF23 1

... point-of-load (POL) application power requirements. Dual-output current can be used where two USB ports are powered by hosts or self-powered hubs. The FPF231X family offers control and protection while providing optimum operation current for safe design practices. The core of each switch is a 75mΩ ( ...
Terminator I/O Discrete Input Modules
Terminator I/O Discrete Input Modules

... integrated 24 VDC power supply bus. T1K-08ND3 and T1K-16ND3 DC input modules include jumpers for selecting the internal 24 VDC power supply available for 2- and 3-wire field devices. Clearly labeled triple stack terminals make it easy to wire 2- and 3-wire devices ensuring clean wiring with only one ...
a matrix converter producing two phase supply from single
a matrix converter producing two phase supply from single

... As shown in figure 1. matrix converter is ac to ac converter, which is also called as direct energy conversion. The direct AC/AC converter provides a direct connection between the input and output terminals without an intermediate energy storage element through an array of semiconductor switches. It ...
CM1451 数据资料DataSheet下载
CM1451 数据资料DataSheet下载

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
THCD-100 - Teledyne Hastings Instruments
THCD-100 - Teledyne Hastings Instruments

... The THCD-100 has two analog voltage input channels. The main input can be configured to accept any input voltage from 0V to a full scale of up to 10V. This input is calibrated using a straight line fit method and then can be displayed on the THCD with an applied range. The secondary input is used to ...
distributed mppt based cascaded h-bridge multilevel inverter
distributed mppt based cascaded h-bridge multilevel inverter

... grid currents in abc coordinates are converted to dq coordinates and regulated through proportional-integral (PI) coordinates, which is then converted back to three phases. The distributed MPPT control scheme for the single-phase system is nearly same. The total voltage controller gives the magnitud ...
HP 34401A User`s Guide
HP 34401A User`s Guide

CSS - CBSE Guess
CSS - CBSE Guess

... Q.1> What is Biot-Savart law? Using it derive the magnetic induction on the axis of a current carrying coil. Q.2> A charged particle ( mass : m & charge : q ) enters a magnetic field B with a velocity V at an angle of θ. What kind of path does the particle describe? Derive a.> Time period b.> Freque ...
ch03 - Computer Science Department
ch03 - Computer Science Department

Design of Third-Order Square-Root-Domain Filters Using
Design of Third-Order Square-Root-Domain Filters Using

... circuits providing low power under low-voltage, having large dynamic range, operating in high frequencies and electronically tunability using DC current sources. Due to these properties, companding circuits are compatible with CMOS very large scale integration technology. Besides these properties, c ...
User`s Guide True RMS Multimeter Extech 430
User`s Guide True RMS Multimeter Extech 430

... Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack. 2. For current measurements up to 4000µA DC, set the function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack ...
ÿþM i c r o s o f t   W o r d   - ` D A 5 D ` D + ` D + . d o c x
ÿþM i c r o s o f t W o r d - ` D A 5 D ` D + ` D + . d o c x

... Fig(7) The fact that voltage is an across variable and exists between two points has resulted in a double-subscript notation that defines the first subscript as the higher potential. In Fig. 7(a), the two points that define the voltage across the resistor R are denoted by (a and b). Since (a) is the ...
Extracting a Linear Model into MATLAB
Extracting a Linear Model into MATLAB

SEL-351 Distribution and Transmission Relay Standard Features
SEL-351 Distribution and Transmission Relay Standard Features

... You select what triggers event reports. Event report length is selectable: 15 or 30 cycles. The voltage, current, frequency, and element status information contained in each report confirms relay, scheme, and system performance for every fault. The relay stores the most ...
CYME 7.2
CYME 7.2

... Enhancements have been brought to the framework and user interface to continue to increase the friendliness and ease-of-use of the software. ...
25471_energy_conversion_4
25471_energy_conversion_4

... the voltage level to transmit the power Step down/Substation transformers – Located at main distribution or secondary level transmission substations to lower the voltage levels for distribution 1st level purposes Distribution Transformers – located at small distribution substation. It lowers the vol ...
High Pass Filter
High Pass Filter

... Xc=impedance of capacitor Vs=voltage across source Zr=impedance of the resistor pair Zc=impedance of capacitor * In the high pass filter circuit, the resistor pair and the capacitor act like a voltage divider.i.e. Vout=Zr/(Zc+Zr). When Zc decreases, the Vout approaches Vs. The voltage gain (which is ...
Technical Article How to Design Wideband Front Ends for GSPS Converters
Technical Article How to Design Wideband Front Ends for GSPS Converters

FPGA-based Servo Control IC for PMLSM Drives with Adaptive
FPGA-based Servo Control IC for PMLSM Drives with Adaptive

... In contrast, if six commutation modes presented in [5] is used in the fourswitch inverter, then there are four floating phases during the operating ...
SIMULATION OF SINUSOIDAL PULSE WIDTH MODULATION
SIMULATION OF SINUSOIDAL PULSE WIDTH MODULATION

... main reason of increasing power quality problems [1] and system losses. Normally, Static Var Compensators (SVCs) have been used in combination with passive filters at the distribution level for mitigation of power quality problems [5], [6] and reactive power compensation. Although SVCs are very effe ...
- Nottingham ePrints
- Nottingham ePrints

- Kewtech
- Kewtech

... clip. This will only work if there is no RCD in this type of system. 5.3 Measurement of PSC (Prospective Short Circuit Current) Warning: Never connect 2 phases to this instrument This is normally measured at the distribution board between the phase and neutral. Select the 20kA, 2000A or 200A range C ...
MAX7500–MAX7504 Digital Temperature Sensors and Thermal Watchdog with Bus Lockup Protection General Description
MAX7500–MAX7504 Digital Temperature Sensors and Thermal Watchdog with Bus Lockup Protection General Description

... All parameters are measured at +25°C. Values over the temperature range are guaranteed by design. There are no industry-wide standards for temperature accuracy specifications. These values allow comparison to vendors who use 3-σ limits. This specification indicates how often temperature data is upda ...
Click Here (.doc)
Click Here (.doc)

MOSFET Theory - Department of Electronics
MOSFET Theory - Department of Electronics

... Cox Cox Cox = VT - ideal + VFB ...
< 1 ... 851 852 853 854 855 856 857 858 859 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report