
Manual (Units installed prior to Nov 2006)
... (c) any Product which has not been operated and maintained in accordance with normal practice and in conformity with recommendations and published specifications of company; and, (d) any Products, component parts or accessories manufactured by others but supplied by Company (any claims should be sub ...
... (c) any Product which has not been operated and maintained in accordance with normal practice and in conformity with recommendations and published specifications of company; and, (d) any Products, component parts or accessories manufactured by others but supplied by Company (any claims should be sub ...
APC Smart
... circuit to the EPO terminal block unless it can be confirmed that the circuit is Class 2 or SELV. If circuit standard cannot be confirmed, use a contact closure switch. Use one of the following cable types to connect the UPS to the EPO switch: ...
... circuit to the EPO terminal block unless it can be confirmed that the circuit is Class 2 or SELV. If circuit standard cannot be confirmed, use a contact closure switch. Use one of the following cable types to connect the UPS to the EPO switch: ...
SimCoder User Manual
... of the digital integrator is set to 1 (for Backward Euler method), and the sampling frequency is set to 20 kHz. The gains k1 and k2 are obtained from the conversion program as described above. In addition, a zero-order-hold block Z1 is used to simulate the A/D converter in digital hardware implement ...
... of the digital integrator is set to 1 (for Backward Euler method), and the sampling frequency is set to 20 kHz. The gains k1 and k2 are obtained from the conversion program as described above. In addition, a zero-order-hold block Z1 is used to simulate the A/D converter in digital hardware implement ...
T.C. Neugebauer and D.J. Perreault, “Parasitic Capacitance Cancellation in Filter Inductors,” IEEE Transactions on Power Electronics , Vol. 21, No. 1, January 2006, pp. 282-288.
... of other filtering and balancing techniques that have been explored in the past. The topology of the filter network that is created [e.g., Fig. 3(b)] is identical to coupled inductor filter structures that have been used widely for everything from notch-filtering [11], [12] to “zero ripple” filters ...
... of other filtering and balancing techniques that have been explored in the past. The topology of the filter network that is created [e.g., Fig. 3(b)] is identical to coupled inductor filter structures that have been used widely for everything from notch-filtering [11], [12] to “zero ripple” filters ...
AN2867
... which means that the open-loop gain should be much higher than 1. The time required for the oscillations to become steady depends on the open-loop gain. Meeting the oscillation conditions is not enough to explain why a crystal oscillator starts to oscillate. Under these conditions, the amplifier is ...
... which means that the open-loop gain should be much higher than 1. The time required for the oscillations to become steady depends on the open-loop gain. Meeting the oscillation conditions is not enough to explain why a crystal oscillator starts to oscillate. Under these conditions, the amplifier is ...
3M™ Termination Kits QT-III 7640-S, 7650-S and 7660
... a skirted insulator, high-dielectric constant (High-K) stress control tube, conformable High-K stress controlling compound and built-in environmental top sealing compound. The two-piece inverted skirted termination assemblies consist of a non-skirted (tubular) insulator, high-dielectric constant (Hi ...
... a skirted insulator, high-dielectric constant (High-K) stress control tube, conformable High-K stress controlling compound and built-in environmental top sealing compound. The two-piece inverted skirted termination assemblies consist of a non-skirted (tubular) insulator, high-dielectric constant (Hi ...
Owner`s Manual - Enerdrive Pty Ltd
... 1. Unless specifically agreed to in writing, Enerdrive Pty Ltd : makes no warranty as to the accuracy, sufficiency or suitability of any technical or other information provided in its manuals or other documentation 2. Assumes no responsibility or liability for losses, damages, costs or expenses, w ...
... 1. Unless specifically agreed to in writing, Enerdrive Pty Ltd : makes no warranty as to the accuracy, sufficiency or suitability of any technical or other information provided in its manuals or other documentation 2. Assumes no responsibility or liability for losses, damages, costs or expenses, w ...
S280-70-8
... This cable also supplies Trip, Close, and Recloser status, and connects to the Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog input module through terminal block TB8. Line current flowing through the recloser is converte ...
... This cable also supplies Trip, Close, and Recloser status, and connects to the Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog input module through terminal block TB8. Line current flowing through the recloser is converte ...
Noise Characterisation of Graphene FETs
... at 1 GHz with 10 dB small-signal power gain is designed, an 8 dB improvement comparing to earlier reports. The amplifier noise figure is measured to be 6.4 ± 0.4 dB at 1 GHz. Modelling by the Pospieszalski temperature noise model predicts the minimum extrinsic and intrinsic noise figure of the G-FET ...
... at 1 GHz with 10 dB small-signal power gain is designed, an 8 dB improvement comparing to earlier reports. The amplifier noise figure is measured to be 6.4 ± 0.4 dB at 1 GHz. Modelling by the Pospieszalski temperature noise model predicts the minimum extrinsic and intrinsic noise figure of the G-FET ...
12248 ODY - BatteryMINDers
... Failure to test a “rested” (see pg. 9) battery will cause false readings. Be certain to read and understand all safety related instructions (pages 3 to 7) before proceeding further. 2. Measure battery’s voltage, without any load attached. If the voltage is less than 12.4 volts (Typically 50% of cha ...
... Failure to test a “rested” (see pg. 9) battery will cause false readings. Be certain to read and understand all safety related instructions (pages 3 to 7) before proceeding further. 2. Measure battery’s voltage, without any load attached. If the voltage is less than 12.4 volts (Typically 50% of cha ...
DigiTrace® 910 Series Heat Trace Controller
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
Distribution Dry-Type Transformers — Low Voltage
... Autotransformer: A transformer in which part of the winding is common to both the primary and the secondary circuits. Banked: Two or more single-phase transformers wired together to supply a three-phase load. Three single-phase transformers can be “banked” together to support a three-phase load. For ...
... Autotransformer: A transformer in which part of the winding is common to both the primary and the secondary circuits. Banked: Two or more single-phase transformers wired together to supply a three-phase load. Three single-phase transformers can be “banked” together to support a three-phase load. For ...
UM0772
... The demonstration kit is powered through the USB A to mini-B cable included in the kit. Using this cable, connect the demonstration board to the PC using the on-board J5 connector. Since the system demonstration makes use of a PC GUI, the USB connection works to power the board and for data transfer ...
... The demonstration kit is powered through the USB A to mini-B cable included in the kit. Using this cable, connect the demonstration board to the PC using the on-board J5 connector. Since the system demonstration makes use of a PC GUI, the USB connection works to power the board and for data transfer ...
Evaluation Board User Guide UG-045
... The AD1938 evaluation board requires a power supply input of ±12 V dc and ground to the three binding posts; +12 V draws ~250 mA, and −12 V draws ~100mA. The on-board regulators provide two 3.3 V rails, one each for AVDD and DVDD for the AD1938. DVDD also supplies power for the active peripheral com ...
... The AD1938 evaluation board requires a power supply input of ±12 V dc and ground to the three binding posts; +12 V draws ~250 mA, and −12 V draws ~100mA. The on-board regulators provide two 3.3 V rails, one each for AVDD and DVDD for the AD1938. DVDD also supplies power for the active peripheral com ...
Alpha Series Amplifier (Servo Amplifier Unit) Maintenance Manual
... European CE marking, ground the motor using the accessory plate terminal. Note that installing more than one protection ground line with single screw makes it impossible for the motor to qualify for European CE marking. (See Appendix NO TAG.) ...
... European CE marking, ground the motor using the accessory plate terminal. Note that installing more than one protection ground line with single screw makes it impossible for the motor to qualify for European CE marking. (See Appendix NO TAG.) ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.