• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SR Latch Circuit
SR Latch Circuit

... The state of a latch or flip-flop is switched by a change in the control input. This momentary change is called a trigger and the transition it causes is said to trigger the flipflop. ...
Chapt34_VGo
Chapt34_VGo

... Both cases can be described by the same law: ...
Control of Breaker-and-a-half diameters and a
Control of Breaker-and-a-half diameters and a

X1 Safety Capacitors
X1 Safety Capacitors

... and neutral in North America, and L1 to L2 in Europe, to suppress differential-mode interference (EMI). NPXH series utilizes metallized polypropylene film with non-inductive & self-healing wound element construction, for stability under VAC operation, and safe end of life failure mode. NPXH series h ...
LTC2436-1 - 2-Channel Differential Input 16
LTC2436-1 - 2-Channel Differential Input 16

AC analyses
AC analyses

MAX3222/MAX3232/MAX3237/MAX3241
MAX3222/MAX3232/MAX3237/MAX3241

High energy impulse generator design
High energy impulse generator design

papers
papers

... 1) In the first stage, the system load/generation is increased via loading parameter  and the resulting nonlinear load flow equations are solved by conventional Newton-Rafson method. This procedure is continued so long as the Newton-Rafson method can be converged. The final solution of conventional ...
MAX3222/MAX3232/MAX3237/MAX3241 3.0V to 5.5V, Low-Power, up to 1Mbps, True RS-232 ________________General Description
MAX3222/MAX3232/MAX3237/MAX3241 3.0V to 5.5V, Low-Power, up to 1Mbps, True RS-232 ________________General Description

... modems to be monitored using only 1µA supply current. The MAX3222 and MAX3232 are pin, package, and functionally compatible with the industry-standard MAX242 and MAX232, respectively. The MAX3241 is a complete serial port (3 drivers/ 5 receivers) designed for notebook and subnotebook computers. The ...
Berechnung von Netztransienten
Berechnung von Netztransienten

Aalborg Universitet Advanced Control Architectures for Intelligent Microgrids—Part II
Aalborg Universitet Advanced Control Architectures for Intelligent Microgrids—Part II

C706 Alternator Troubleshooting Guide
C706 Alternator Troubleshooting Guide

... Install a jumper from pin F in harness plug to B+ terminal on alternator. Momentarily (1 sec.) jumper pin A in harness plug to alternator B– terminal. Touch shaft with steel tool to detect significant magnetism. Is shaft magnetized? ...
Independent Living Aids ILA Item 756246 Digital Multimeter With
Independent Living Aids ILA Item 756246 Digital Multimeter With

... suggestions will help you care for the meter so you can enjoy it for years.  Keep the meter dry. If it gets wet, wipe it dry immediately. Liquids might contain minerals that can corrode the electronic circuits.  Use and store the meter only in normal temperature environments. Temperature extremes ...
W225-10022
W225-10022

... maximum continuous (thermal) current rating. A series transformer is placed in series with the line in lieu of a tapped series winding. A tapped secondary winding of a shunt (excitation) transformer is connected to the tap changer. A division in load current occurs at the series transformer with a p ...
HK2413161321
HK2413161321

... watchdog timers, and pulse width modulated outputs. Variations of the 8051 with clock speeds up to 40MHz and voltage requirements down to 1.5 volts are available. This wide range of parts based on one core makes the 8051 family an excellent choice as the base architecture for a company's entire line ...
Pinning down the last spin NEWS & VIEWS QUANTUM POINT CONTACTS
Pinning down the last spin NEWS & VIEWS QUANTUM POINT CONTACTS

... electron spin in QPCs. QPCs are typically fabricated by so-called split-gate electrodes on n-type AlGaAs–GaAs heterostructures. In 1988, it was reported that the conductance of such devices is quantized in units of 2e2/h (refs 2,3). An experimental example of such observations is shown in Fig.1. The ...
mfiis template
mfiis template

... inputvoltages and powers and compared with the lossapproximations used in the design. At low current operationthe converter operates at approximately 98% efficiency. Asthe converter power is increased the efficiency drops as low as 90 %. The expected efficiency at minimum input voltage, 50 V, is wit ...
P723X Manual
P723X Manual

1002 eDIN DMX Repeater Spec
1002 eDIN DMX Repeater Spec

... data line. The power input shall be supplied by a Class 2 circuit. It shall accept a range of 9 to 30 volts DC and shall consume no more than 5 watts. All DMX input and output ports shall be capable of withstanding short-term application of up to 250V without damage to internal components. Port prot ...
Aalborg Universitet Advanced Control Architectures for
Aalborg Universitet Advanced Control Architectures for

Transmission and Distribution Networks: AC versus DC - SOLAREC-E
Transmission and Distribution Networks: AC versus DC - SOLAREC-E

... Alternating current (AC) offered much better efficiency, since it could easily be transformed to higher voltages, with far less loss of power. AC technology was soon accepted as the only feasible technology for generation, transmission and distribution of electrical energy. ...
Lab 8: Frequency Response and Passive Filters
Lab 8: Frequency Response and Passive Filters

BQ2040 数据资料 dataSheet 下载
BQ2040 数据资料 dataSheet 下载

... The bq2040 also automatically recalibrates or “learns” battery capacity in the full course of a discharge cycle from full to empty. The bq2040 may operate directly from three nickel chemistry cells. With the REF output and an external transistor, a simple, inexpensive regulator can be built to provi ...
02_B_AVR (PPTmin) - Colorado Space Grant Consortium
02_B_AVR (PPTmin) - Colorado Space Grant Consortium

... X & Y Axis Accelerometers Z Axis Accelerometers Geiger Counter Interface ...
< 1 ... 603 604 605 606 607 608 609 610 611 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report