V DD - BME – EET
... • At switching the CL load capacitance is charged to VDD through the p-channel device when the output changes to 1, later, when switching the output to 0, it is discharged towards GND through the n-channel device. ...
... • At switching the CL load capacitance is charged to VDD through the p-channel device when the output changes to 1, later, when switching the output to 0, it is discharged towards GND through the n-channel device. ...
SIGC25T120C IGBT Chip in NPT-technology
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
For Full Text Click Here
... there is also a growing interest in commercial use of UWB technology such as in Wireless Personal Area Networks (WPAN), [3, 4]. This interest has been the result of increasing demand for much higher data rates on the order of hundreds of megabits since future wireless networks requires very large tr ...
... there is also a growing interest in commercial use of UWB technology such as in Wireless Personal Area Networks (WPAN), [3, 4]. This interest has been the result of increasing demand for much higher data rates on the order of hundreds of megabits since future wireless networks requires very large tr ...
Simple 43-foot 160/80 meter manual matching
... Operation To use the matching unit, just connect it to the base of the antenna in place of the normal unun when you want to operate on 160- or 80-meters. Select either 160- or 80-meters with the external straps. You can connect both the original unun and this matching unit to the antenna at the same ...
... Operation To use the matching unit, just connect it to the base of the antenna in place of the normal unun when you want to operate on 160- or 80-meters. Select either 160- or 80-meters with the external straps. You can connect both the original unun and this matching unit to the antenna at the same ...
Generator Third-Harmonic Stator Ground Fault Detection Element
... harmonic voltage produced by the generator and the distribution of that voltage across the ground zone impedances. To maintain element security, it may be necessary to disable the 64G element while the generator breaker is open, relying only on the 59N element for ground fault detection during this ...
... harmonic voltage produced by the generator and the distribution of that voltage across the ground zone impedances. To maintain element security, it may be necessary to disable the 64G element while the generator breaker is open, relying only on the 59N element for ground fault detection during this ...
power quality improvement using hybrid power filter
... They have many negative effects on power system equipment and customer, such as additional losses in overhead lines and underground cables, transformers and rotating electric machines, problem in the operation of the protection systems, over voltage and shunt capacitor, error of measuring instrument ...
... They have many negative effects on power system equipment and customer, such as additional losses in overhead lines and underground cables, transformers and rotating electric machines, problem in the operation of the protection systems, over voltage and shunt capacitor, error of measuring instrument ...
Sepam™ Series 80 Protective Relays
... digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and u ...
... digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and u ...
Florida Department of Transportation
... signal head indication field terminal and the AC neutral circuit in the controller cabinet during the off (dark) state of each signal head indication. Ensure that the voltage does not exceed 2 VAC, RMS. If this value is exceeded, take the following action to reduce the value to 2 VAC, RMS: (1) Check ...
... signal head indication field terminal and the AC neutral circuit in the controller cabinet during the off (dark) state of each signal head indication. Ensure that the voltage does not exceed 2 VAC, RMS. If this value is exceeded, take the following action to reduce the value to 2 VAC, RMS: (1) Check ...
Period 13 Activity Sheet: Electrical Resistance and Joule Heating
... Relationship between R, L, A, and ρ: We have found that the resistance of a wire, R, is directly proportional to length, L, and inversely proportional to the cross-sectional area, A. For a given type material, the resistivity, ρ, is directly proportional to the resistance. Using these variables, wri ...
... Relationship between R, L, A, and ρ: We have found that the resistance of a wire, R, is directly proportional to length, L, and inversely proportional to the cross-sectional area, A. For a given type material, the resistivity, ρ, is directly proportional to the resistance. Using these variables, wri ...
Indiana University – Purdue University Fort Wayne Department of Engineering Project Title:
... The following list of data was taken during a test run in which the MCU was performing ADCs on the three output ports of the accelerometer while the accelerometer was experiencing dynamic accelerations. The list is an excerpt from a text file that is generated to show the measurements of signals out ...
... The following list of data was taken during a test run in which the MCU was performing ADCs on the three output ports of the accelerometer while the accelerometer was experiencing dynamic accelerations. The list is an excerpt from a text file that is generated to show the measurements of signals out ...
MAX6662 12-Bit + Sign Temperature Sensor with SPI-Compatible Serial Interface General Description
... and a 3-wire (SPI™-compatible) serial interface in a single package. It converts its die temperature into digital values using an internal analog-to-digital converter (ADC). The temperature data is stored in a temperature register as a 13-bit word, which allows 0.0625°C resolution. The temperature d ...
... and a 3-wire (SPI™-compatible) serial interface in a single package. It converts its die temperature into digital values using an internal analog-to-digital converter (ADC). The temperature data is stored in a temperature register as a 13-bit word, which allows 0.0625°C resolution. The temperature d ...
What reliably supplies 24 V DC
... The optimal power supply for SIMATIC S7 and more The design and functionality of the original power supplies of the SIMATIC merge optimally into the PLC network. As well as the following SIMATIC systems, they also supply other loads reliably with 24 V DC: • SIMATIC S7-1200 – the new micro PLC is sup ...
... The optimal power supply for SIMATIC S7 and more The design and functionality of the original power supplies of the SIMATIC merge optimally into the PLC network. As well as the following SIMATIC systems, they also supply other loads reliably with 24 V DC: • SIMATIC S7-1200 – the new micro PLC is sup ...
Amorpho us metal core technology
... in Europe and the US to reduce load losses with products being promoted as ‘low loss’ transformers. Amorphous metal core technology has been intensively deployed in countries with notoriously overstretched supply networks (i.e. India) for over two decades and has a proven track record of performance ...
... in Europe and the US to reduce load losses with products being promoted as ‘low loss’ transformers. Amorphous metal core technology has been intensively deployed in countries with notoriously overstretched supply networks (i.e. India) for over two decades and has a proven track record of performance ...
A low-noise and wide-band ac boosting current-to-voltage
... In scanning tunneling microscopy (STM), the tunneling current between the tip and the sample contains all the essential informations. The tunneling current provides the basic topography of the sample surface for the determination of the atomic structure, and it gives the tunneling spectroscopy for t ...
... In scanning tunneling microscopy (STM), the tunneling current between the tip and the sample contains all the essential informations. The tunneling current provides the basic topography of the sample surface for the determination of the atomic structure, and it gives the tunneling spectroscopy for t ...
EnergyCyc2 Presentation 1.1
... Electric versus Electronic What is the difference? An electronic circuit contains at least one transistor or tube. Devices which contain electronic circuits (TVs, radios, iPods) are electronic. Electric motors are never electronic because they do not contain transistors or tubes. Most motor control ...
... Electric versus Electronic What is the difference? An electronic circuit contains at least one transistor or tube. Devices which contain electronic circuits (TVs, radios, iPods) are electronic. Electric motors are never electronic because they do not contain transistors or tubes. Most motor control ...
A Learning Guide for Model Rocket Launch Systems
... the safety interlock key is inserted into it to complete the circuit. Once this key is inserted, the electricity can flow from the dry cells, through a wire to a micro-clip, through the igniter attached to the micro-clips, through the other of the long pair of wires to the bulb, through the safety i ...
... the safety interlock key is inserted into it to complete the circuit. Once this key is inserted, the electricity can flow from the dry cells, through a wire to a micro-clip, through the igniter attached to the micro-clips, through the other of the long pair of wires to the bulb, through the safety i ...
Atmel ATA5756/ATA5757 UHF ASK/FSK Transmitter Features DATASHEET
... If ASK = Low, FSK = Low and ENABLE = open or Low, the circuit is in power-down mode consuming only a very small amount of current so that a lithium cell used as power supply can work for many years. If the ENABLE pin is left open, ENABLE is the logical OR operation of the ASK and FSK input pins. Thi ...
... If ASK = Low, FSK = Low and ENABLE = open or Low, the circuit is in power-down mode consuming only a very small amount of current so that a lithium cell used as power supply can work for many years. If the ENABLE pin is left open, ENABLE is the logical OR operation of the ASK and FSK input pins. Thi ...
this Manual - Blue Sky Energy Inc.
... WARNING – This unit is not provided with a GFDI (ground-fault detector/interrupter) device and must be used with an external GFDI device as required by Article 690 of National Electrical Code for the installation location. 5. PREPARING TO CHARGE a) Never charge a frozen battery. b) Be sure battery i ...
... WARNING – This unit is not provided with a GFDI (ground-fault detector/interrupter) device and must be used with an external GFDI device as required by Article 690 of National Electrical Code for the installation location. 5. PREPARING TO CHARGE a) Never charge a frozen battery. b) Be sure battery i ...
MAX7327 I C Port Expander with 12 Push-Pull Outputs and 4 Open-Drain I/Os
... The four open-drain ports offer latching transition detection functionality when used as inputs. All input ports are continuously monitored for changes. An input change sets 1 of 4 flag bits that identify the changed input(s). All flags are cleared upon a subsequent read or write transaction to the ...
... The four open-drain ports offer latching transition detection functionality when used as inputs. All input ports are continuously monitored for changes. An input change sets 1 of 4 flag bits that identify the changed input(s). All flags are cleared upon a subsequent read or write transaction to the ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.