• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Switch Mode DC Power Supply with Battery Backup SEC
Switch Mode DC Power Supply with Battery Backup SEC

... Uninterruptible Power Source (DC UPS) in conjunction with an external 12V, Lead Acid backup battery. As long as AC input power is available, the unit will put out 13.8 ± 0.1V at the Load Terminals (3, 4) and provide a maximum continuous load current of 19A to 23A. At the same time, charging current ...
Wireless Clamp Meter - Fieldpiece Instruments
Wireless Clamp Meter - Fieldpiece Instruments

... thermocouples to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used. Ideally you should calibrate to a known temperature closest to the temperatures you will be testing. 1. Rotate dial to the °F °C, T ...
DS3174DK DS3/E3 Single-Chip Transceiver Demo Kit
DS3174DK DS3/E3 Single-Chip Transceiver Demo Kit

... Standard high-speed layout guidelines should be observed when designing a PC board to support the DS3174. The following guidelines help to provide stable supply voltages and signal integrity between devices. The DS3174 should have a low-impedance power-supply path that is accomplished with plane lay ...
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of

... that impacts a larger area. A regional blackout lasting more than several days could already be considered as a worst case scenario. Most back-up and security systems will fail after a longer period without electric power, leading to an almost complete failure of most critical infrastructures. One o ...
A 56-GHz LC-Tank VCO With 17% Tuning Range in 65
A 56-GHz LC-Tank VCO With 17% Tuning Range in 65

Design overhead distribution systems
Design overhead distribution systems

... for long distance transmission, or some undersea cables, or for connecting two different ac networks. Electricity is transmitted at high voltages (110 kV or above) to reduce the energy lost in transmission. Power is usually transmitted as alternating current through overhead power lines. Underground ...
DS2740 High-Precision Coulomb Counter  PIN CONFIGURATION
DS2740 High-Precision Coulomb Counter PIN CONFIGURATION

... Skip Net Address [CCh]. This command saves time when there is only one DS2740 on the bus by allowing the bus master to issue a function command without specifying the address of the slave. If more than one slave device is present on the bus, a subsequent function command can cause a data collision w ...
3 Noise in Physical Systems
3 Noise in Physical Systems

... (the cross terms n 6= m vanish in the expectation because their times are independent). We see that the power spectrum of carrier arrivals is white (flat) and that the magnitude is linearly proportional to the current. This is called shot noise or Schottky noise. If the carriers do not really arrive ...
Konstantin Stefanov`s talk at LCUK in Durham
Konstantin Stefanov`s talk at LCUK in Durham

chapter 07 Passive Devices
chapter 07 Passive Devices

Conductor Protection (Wire Cable Protection) 1
Conductor Protection (Wire Cable Protection) 1

... accepted based on a study conducted by the Small Wire Working Group formed by the NFPA 79 Committee. The Small Wire Working Group studied the critical application considerations for small conductors in industrial machinery, proposed the requirements and conducted UL witnessed tests to prove the prop ...
Attachment 3
Attachment 3

... - The TRV magnitudes for most applications will be based on a Kpp=1.3 - The TRV magnitudes for special applications will be based on a Kpp=1.5 B. The chairman then presented a review of the TRV peak calculations using the expression Uc = sqrt(2/3) x Kpp x Kaf x Ur The values of Uc at currents less t ...
"Is My UPS Distribution System Coordinated?
"Is My UPS Distribution System Coordinated?

... UPS Distribution System General Protection Application Guideline Summary 11. UPS internal fuse/circuit breaker configurations vary, and the specifics must be confirmed with each manufacturer. Also, the manufacturer should confirm the Alternate Source fault magnitude does not exceed the UPS Alternate ...
Physics II Final Exam Review
Physics II Final Exam Review

• - My Jaguar Story
• - My Jaguar Story

... Chemical corrosion can also lead to the formation of small hard deposits of metals and rust within the radiator or engine block causing hard to find overheating problems. These deposits can be very hard to shift if they have been building up over a period of time and as such, become firmly lodged in ...
TSC2008 数据资料 dataSheet 下载
TSC2008 数据资料 dataSheet 下载

... handheld applications that are based on advanced low-voltage processors. It works with a supply voltage as low as 1.2V, which can be supplied by a single-cell battery. It contains a complete, ultra-low power, 12-bit, analog-to-digital (A/D) resistive touch screen converter, including drivers and the ...
Not Used - Michigan State University
Not Used - Michigan State University

... Field selection of Automatic Hold Return to select automatic return to a preferred source or holding on the alternate source after the initial automatic transfer operation. ...
Battery Charging Terminology
Battery Charging Terminology

... means the battery can provide 10 Amps for 10 hours to an end of discharge voltage of 1.75V per cell. Different battery manufacturers will use different Cxx rates depending on the market or application at which their batteries are targeted. Typical rates used are C3, C5, C8, C10 and C20. Because of t ...
Guide to Commercial Installations Distribution Boards
Guide to Commercial Installations Distribution Boards

... The whole nature of electrical sub and final distribution for commercial installations has changed in the last few years. There is a demand for more RCD protection of final circuits, more metering and often more control to meet energy saving targets. This guide expands upon some of the requirements ...
16.1 Electric Potential Energy and Electric
16.1 Electric Potential Energy and Electric

... The electron-volt is a unit of energy, not voltage, and is not an SI standard unit. It is, however, quite useful when dealing with energies on the atomic scale. © 2010 Pearson Education, Inc. ...
BT044436441
BT044436441

... to create a rotational field with low torque ripples. In this respect, the BLDC motor is equivalent to an inverted DC commutator motor in that the magnets rotates while the conductors remain stationary is reversed by the commutator and the brushes, but in the brushless DC motor, the polarity reversa ...
AD9863 - Analog Devices
AD9863 - Analog Devices

... and less. The dual TxDACs operate at speeds up to 200 MHz and include a bypassable 2× or 4× interpolation filter. The AD9863 is optimized for high performance, low power, and small form factor to provide a cost-effective solution for the broadband communications market. The AD9863 uses a single inpu ...
Aalborg Universitet microgrids
Aalborg Universitet microgrids

... only a high bandwidth current control loop is needed in this method which simplifies the inner voltage and current control loop design. However, the performance of the method is deteriorated due to the so-called ‘whack-a-mole’ effect [11]. Harmonic voltages are magnified on other buses even though t ...
WM8731 Portable Internet Audio CODEC with Headphone Driver and Programmable Sample Rates DESCRIPTION
WM8731 Portable Internet Audio CODEC with Headphone Driver and Programmable Sample Rates DESCRIPTION

File - Dou Yee Enterprises
File - Dou Yee Enterprises

< 1 ... 421 422 423 424 425 426 427 428 429 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report