• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Interface Connection Connectors
Interface Connection Connectors

... *A metal shielding cover integrating the connection part which connects to the plug's shell is used. Because there is no gap between the receptacle and the plug, this construction prevents the entry of space conductive noise. *The flange construction allows the receptacle to be secured on the equipm ...
B. Transient Protection Modules
B. Transient Protection Modules

... the device. The terminals shall be UL rated for 300 Volts and accept a maximum of two wires rated number 24 to number 14 AWG. ...
Product note Medium and high voltage generators for
Product note Medium and high voltage generators for

... the generators compact and easy to install – factors that are important in the genset business. In parallel operation no additional PLCs or cabling are needed to realize Voltage Droop Compensation (VDC) control. For grid operation, ABB’s cutting-edge digital AVR option completes the high performance ...
user manual
user manual

... industry’s most advanced technologies, including audio and video systems, homenetworking and music distribution. The guiding principle at Goldmund is to produce a precise sound with the least possible loss of quality through the different stages. Goldmund will never adopt a technology before it is s ...
AquaLink® RS
AquaLink® RS

... To Reduce the Risk of Injury a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. b) Since excessive ...
111 GuardSwitch Installation
111 GuardSwitch Installation

... sensing face ...
Microelectromechanical Devices
Microelectromechanical Devices

... torque to the base speed (b). However, it is often desirable to operate at higher speeds (e.g. in electric vehicles). Above base speed, however, the induced emf will exceed the input voltage and so current cannot be fed into the motor. By reducing the induced emf, by weakening the air gap flux link ...
DC Parameters: Input Offset Voltage (VIO)
DC Parameters: Input Offset Voltage (VIO)

Power Factor Correction Handbook
Power Factor Correction Handbook

... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
FT300-LV Auto Thyristor Switching Cap Bank Tech Spec
FT300-LV Auto Thyristor Switching Cap Bank Tech Spec

... above are possible but not typically economical nor necessary to meet power factor requirements in North America. Normal tuning of detuned systems is 4.2 x 60 Hz for North American voltages ( 480V, 600V). Filter tuning systems. We do not recommend specifying higher tuning points without a detailed n ...
transistor - Mine
transistor - Mine

Transformerless UPS systems and the 9900
Transformerless UPS systems and the 9900

AILD-1 Automotive Instrumentation Lighting Dimmer DIY Kit
AILD-1 Automotive Instrumentation Lighting Dimmer DIY Kit

... 2. Disconnect either one of the wires between the rheostat and the dimmer module. As long as the rheostat is disconnected, the status indicator (red LED) will flash at 1 Hz. 3. Ground the Rheostat A terminal on the dimmer module five times (by connecting it with a wire to the Ground terminal on the ...
17227 1 - SK Engineering Academy
17227 1 - SK Engineering Academy

... operate, there should be sufficiently quick backup protection so that the rest of the system is protected. By coordinating relays, faults can always be isolated quickly without serious disturbance to the rest of the system. 9. Give the limitations of Merz Price protection. Since neutral earthing res ...
Objective – 2 - cloudfront.net
Objective – 2 - cloudfront.net

... (A) 1, 2, 3 and 4 (B) 4, 2, 3 and 1 (C) 1, 3, 2 and 4 (D) 4, 3, 2 and 1 (D) In a p–n junction diode under reverse bias, the magnitude of electric field is maximum at (A) The edge of the depletion region on the p side (B) The edge of the depletion region on the n side (C) The p–n junction (D) The cen ...
BSPD Series
BSPD Series

IntelliMotor ITM-23Q Hardware Manual ®
IntelliMotor ITM-23Q Hardware Manual ®

AN2323
AN2323

... multiplier window, as shown in Figure 10. These values are those provided by the phantom load equipment and are also shown in Table 5 above. One multiplier factor should be taken at a time. Read the offsets by clicking on the Read icon. After taking a set of readings, click on the Write icon. After ...
Inter-system Ground Noise: Causes and Effects
Inter-system Ground Noise: Causes and Effects

... If the interconnected devices are on different electrical circuits in the building and one of these circuits is shared by some other unrelated equipment, which has an insulation failure, then before the circuit breaker trips, a very large fault current will be injected into the safety ground wire. T ...
Section 4 Thyristor General Elec Product
Section 4 Thyristor General Elec Product

... The Sidac is a multi-layer silicon semiconductor switch. The Sidac operates as a bidirectional switch activated by voltage. In the off state, the Sidac exhibits leakage currents (IDRM) less than 5 µA. As applied voltage exceeds the sidac VBO, the device begins to enter a negative resistance switchin ...
Wireless Speed and Direction Control of Dc Motor by Using
Wireless Speed and Direction Control of Dc Motor by Using

... the speed of a DC motor. Power is supplied to the motor in square wave of constant voltage but varying pulse-width or duty cycle. Duty cycle refers to the percentage of one cycle during which duty cycle of a continuous train of pulses. Since the frequency is held constant while the on-off time is va ...
04_DC AC Meter - UniMAP Portal
04_DC AC Meter - UniMAP Portal

... attraction is very small for common voltages. It is so small that such meter movement designs are impractical for use in general test instruments.  Typically, electrostatic meter movements are used for ...
NT - JNEC
NT - JNEC

... It is my great pleasure to present this laboratory manual for second year engineering students for the subject of Network Theory, keeping in view the vast coverage required to visualize the basic concepts of various networks using basic components. NT covers designing a network for specific input/ou ...
User Manual Power-Lite - Perfect Power Systems
User Manual Power-Lite - Perfect Power Systems

... System) including computers, workstations, process control systems, telecommunications systems, sales terminals, other critical instrumentation, etc. The purpose of the UPS is to protect these systems from poor quality utility power, complete loss of power, or other associated problems. Electrical i ...
HyPower battery charging procedure
HyPower battery charging procedure

... The batteries used on the HyPower system can provide a longer, more satisfactory service life if they are charged in a specific manner. This is necessary so that each battery in the series is brought to the optimal charged state. To help optimize battery performance, the following changes have been ...
< 1 ... 415 416 417 418 419 420 421 422 423 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report