ADXRS646 英文数据手册DataSheet 下载
... (gyroscope) that offers excellent vibration immunity. Bias stability is a widely-recognized figure of merit for high performance gyroscopes, but in real-world applications, vibration sensitivity is often a more significant performance limitation and should be considered in gyroscope selection. The A ...
... (gyroscope) that offers excellent vibration immunity. Bias stability is a widely-recognized figure of merit for high performance gyroscopes, but in real-world applications, vibration sensitivity is often a more significant performance limitation and should be considered in gyroscope selection. The A ...
OP-AMP
... when the feedback resistor (Rf) is zero. The Op-Amp operates as a comparator and not as a linear amplifier. ...
... when the feedback resistor (Rf) is zero. The Op-Amp operates as a comparator and not as a linear amplifier. ...
HMC955LC4B - Hittite Microwave Corporation
... demux uses both rising and falling edges of the half-rate clock to sample the data in sequence 01-02 and latches the data on the rising edge into the differential outputs. The demux also has high-speed clock synchronous invert input that allows for scrambling of the data. The HMC955LC4B also feature ...
... demux uses both rising and falling edges of the half-rate clock to sample the data in sequence 01-02 and latches the data on the rising edge into the differential outputs. The demux also has high-speed clock synchronous invert input that allows for scrambling of the data. The HMC955LC4B also feature ...
CS5101AN/D Secondary Side Post Regulator (SSPR) for
... The SSPR can be used in a variety of topologies including both single and dual ended buck or flyback converters operating with current or voltage mode control. In each case, usually the N–FET power switch is connected in series with the forward diode as shown in Figure 7. Since the N–FET is connecte ...
... The SSPR can be used in a variety of topologies including both single and dual ended buck or flyback converters operating with current or voltage mode control. In each case, usually the N–FET power switch is connected in series with the forward diode as shown in Figure 7. Since the N–FET is connecte ...
Kerr effect
... This linearly polarized wave is turned by 90 ° with respect to the direction of incidence, e. g. with respect to the vertical. The applied voltage is therefore called the “half-wave voltage”. In this case the light intensity behind the analyser which is at an angle of 90 ° to the polarizer will show ...
... This linearly polarized wave is turned by 90 ° with respect to the direction of incidence, e. g. with respect to the vertical. The applied voltage is therefore called the “half-wave voltage”. In this case the light intensity behind the analyser which is at an angle of 90 ° to the polarizer will show ...
Dual J-K flip flop with clear
... Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implicatio ...
... Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implicatio ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
... magnet mechanism and current is induced into the stationary armature. In the permanent magnet synchronous generator, the magnetic field is obtained by using a permanent magnet, but not an electromagnet. The field flux remains constant in this case and the supply required to excite the field winding ...
... magnet mechanism and current is induced into the stationary armature. In the permanent magnet synchronous generator, the magnetic field is obtained by using a permanent magnet, but not an electromagnet. The field flux remains constant in this case and the supply required to excite the field winding ...
CPH5505 数据资料DataSheet下载
... the customer should always evaluate and test devices mounted in the customer's products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all semiconductor products fail with some probability. It is possible that these probabilistic fai ...
... the customer should always evaluate and test devices mounted in the customer's products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all semiconductor products fail with some probability. It is possible that these probabilistic fai ...
RF3378 GENERAL PURPOSE AMPLIFIER Features
... Note 1: All specification and characterization data has been gathered on standard FR-4 evaluation boards. These evaluation boards are not optimized for frequencies above 2.5GHz. Performance above 2.5GHz may improve if a high performance PCB is used. Note 2: The RF3378 must be operated at or below 60 ...
... Note 1: All specification and characterization data has been gathered on standard FR-4 evaluation boards. These evaluation boards are not optimized for frequencies above 2.5GHz. Performance above 2.5GHz may improve if a high performance PCB is used. Note 2: The RF3378 must be operated at or below 60 ...
Design of a Low Noise Amplifier and Mixer in 0
... senses the periodic waveform generated by the local oscillator. The IF port contains the frequency translated signal. ...
... senses the periodic waveform generated by the local oscillator. The IF port contains the frequency translated signal. ...
Instructions, Gaussmeter, Cable, and HALLCAL.EXE
... wire is often too high. Hall generators are normally connected using twisted pairs of copper wire such as 34 gauge, Teflon insulated. There are two reasons for this: 1. The gaussmeter current source is limited in compliance voltage. The gaussmeter should not drive a load (Hall sensor, wires in cryos ...
... wire is often too high. Hall generators are normally connected using twisted pairs of copper wire such as 34 gauge, Teflon insulated. There are two reasons for this: 1. The gaussmeter current source is limited in compliance voltage. The gaussmeter should not drive a load (Hall sensor, wires in cryos ...
TL783 - Texas Instruments
... and a DMOS output transistor capable of sourcing more than 700 mA. It is designed for use in high-voltage applications where standard bipolar regulators cannot be used. Excellent performance specifications, superior to those of most bipolar regulators, are achieved through circuit design and advance ...
... and a DMOS output transistor capable of sourcing more than 700 mA. It is designed for use in high-voltage applications where standard bipolar regulators cannot be used. Excellent performance specifications, superior to those of most bipolar regulators, are achieved through circuit design and advance ...
CT1000, CT200, CT60 AC/DC Current Sensor User`s Manual
... • Only pass conductors through the primary conductor feed-through hole if the current that you want to measure is flowing through the conductors and their current directions are the same. Correct measurements cannot be taken if you pass conductors with magnetic shielding or conductors whose current ...
... • Only pass conductors through the primary conductor feed-through hole if the current that you want to measure is flowing through the conductors and their current directions are the same. Correct measurements cannot be taken if you pass conductors with magnetic shielding or conductors whose current ...
GS-D200 GS-D200S 2/2.5A BIPOLAR STEPPER MOTOR DRIVE MODULES
... frequency must be decreased: this is easily obtained by connecting an external capacitor between OSC pin and GND1. In these conditions a fast decay (CONTROL LOW) would impose a low average current and the torque could be inadequate. By selecting CONTROL HIGH, the average current is increased thanks ...
... frequency must be decreased: this is easily obtained by connecting an external capacitor between OSC pin and GND1. In these conditions a fast decay (CONTROL LOW) would impose a low average current and the torque could be inadequate. By selecting CONTROL HIGH, the average current is increased thanks ...
General Specifications Model UP150 Program Temperature Controller
... CSA1010) Pollution degree: 2 (IEC/EN 61010, CSA1010) Measurement category: 1 (CAT.1: IEC/EN61010) Rated measurement input voltage: 10V DC max. (across terminals), 300 V AC max. (across ground) Rated trasient overvoltage: 1500 V (Note) Note: It is a value on the safety standard which is assumed by IE ...
... CSA1010) Pollution degree: 2 (IEC/EN 61010, CSA1010) Measurement category: 1 (CAT.1: IEC/EN61010) Rated measurement input voltage: 10V DC max. (across terminals), 300 V AC max. (across ground) Rated trasient overvoltage: 1500 V (Note) Note: It is a value on the safety standard which is assumed by IE ...
LB-47 - Texas Instruments
... An improved approach is shown in Figure 2 . Here an LM329B 6.9V zener reference has been stacked in series with the LM317’s internal reference. This both improves temperature stability, since the LM329B has a guaranteed TC of g 20 ppm/§ C, and improves regulation, because more loop gain is available ...
... An improved approach is shown in Figure 2 . Here an LM329B 6.9V zener reference has been stacked in series with the LM317’s internal reference. This both improves temperature stability, since the LM329B has a guaranteed TC of g 20 ppm/§ C, and improves regulation, because more loop gain is available ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.