StrainBook/616 - Measurement Computing
... WaveView supports up to 64 channels of strain, voltage, or sound/vibration input. For applications beyond 64 channels, or for custom applications, comprehensive drivers are included for Windows languages, LabVIEW®, and DASYLab®. StrainBook/616 includes a 1 MHz A/D converter that can scan all select ...
... WaveView supports up to 64 channels of strain, voltage, or sound/vibration input. For applications beyond 64 channels, or for custom applications, comprehensive drivers are included for Windows languages, LabVIEW®, and DASYLab®. StrainBook/616 includes a 1 MHz A/D converter that can scan all select ...
Section [26 33 63] [16611]
... performance of the work, and as shown on the Drawings and as herein specified. ...
... performance of the work, and as shown on the Drawings and as herein specified. ...
Current measurement in power electronic and
... drives. Current measurement is used for control, protection, monitoring, and power management purposes. Parameters such as low cost, accuracy, high current measurement, isolation needs, broad frequency bandwidth, linearity and stability with temperature variations, high immunity to dv/dt, low realiz ...
... drives. Current measurement is used for control, protection, monitoring, and power management purposes. Parameters such as low cost, accuracy, high current measurement, isolation needs, broad frequency bandwidth, linearity and stability with temperature variations, high immunity to dv/dt, low realiz ...
TJA1021
... on the bus. The receiver has a supply-voltage related threshold with hysteresis and an integrated filter to suppress bus line noise. The transmit data stream of the protocol controller at the TXD input is converted by the transmitter into a bus signal with optimized slew rate and wave shaping to min ...
... on the bus. The receiver has a supply-voltage related threshold with hysteresis and an integrated filter to suppress bus line noise. The transmit data stream of the protocol controller at the TXD input is converted by the transmitter into a bus signal with optimized slew rate and wave shaping to min ...
TC10 Owner`s Manual Xantrex Truecharge 10 Battery Charger
... Truecharge 10 implements the three-step charging process. In the first step, known as the bulk charge, the Truecharge 10 delivers its rated current (10 A) until the battery voltage approaches its gassing voltage—typically around 14.4 volts. The bulk charge step restores about 75% of the battery's ch ...
... Truecharge 10 implements the three-step charging process. In the first step, known as the bulk charge, the Truecharge 10 delivers its rated current (10 A) until the battery voltage approaches its gassing voltage—typically around 14.4 volts. The bulk charge step restores about 75% of the battery's ch ...
4-Channel, Low Noise, Low Power, 24-Bit, Sigma
... inputs or seven single-ended or pseudo differential inputs. The on-chip low gain stage ensures that signals of small amplitude can be interfaced directly to the ADC. One of the major advantages of the AD7124-4 is that it gives the user the flexibility to employ one of three integrated power modes. T ...
... inputs or seven single-ended or pseudo differential inputs. The on-chip low gain stage ensures that signals of small amplitude can be interfaced directly to the ADC. One of the major advantages of the AD7124-4 is that it gives the user the flexibility to employ one of three integrated power modes. T ...
AD9862
... and demultiplexer circuitry can process real or I/Q data. Interpolation rates of 2 and 4 are available to ease requirements on an external reconstruction filter. For single channel systems, the digital Hilbert filter can be used with an external quadrature modulator to create an image rejection ar ...
... and demultiplexer circuitry can process real or I/Q data. Interpolation rates of 2 and 4 are available to ease requirements on an external reconstruction filter. For single channel systems, the digital Hilbert filter can be used with an external quadrature modulator to create an image rejection ar ...
Virtex-5 FPGA PCB Designer’s Guide www.BDTIC.com/XILINX UG203 (v1.4) April 20, 2009
... PCB technology has not changed significantly in the last few decades. An insulator substrate material (usually FR4, an epoxy/glass composite) with copper plating on both sides has portions of copper etched away to form conductive paths. Layers of plated and etched substrates are glued together in a ...
... PCB technology has not changed significantly in the last few decades. An insulator substrate material (usually FR4, an epoxy/glass composite) with copper plating on both sides has portions of copper etched away to form conductive paths. Layers of plated and etched substrates are glued together in a ...
battery/charging system
... normal use, the performance of the battery deteriorates after 2-3 years. Battery voltage may recover after battery charging, but under heavy load, the battery voltage will drop quickly and eventually die out. For this reason, the charging system is often suspected as the problem. Battery overcharge ...
... normal use, the performance of the battery deteriorates after 2-3 years. Battery voltage may recover after battery charging, but under heavy load, the battery voltage will drop quickly and eventually die out. For this reason, the charging system is often suspected as the problem. Battery overcharge ...
Handbook on Electricity Meters
... Phase angle - in degrees lead or lag Active power - in Watts (W) Reactive power - in Reactive Volt-Amperes (VARs) Apparent power - in Volt-Amperes (VA) Power factor - as a ratio or percent ...
... Phase angle - in degrees lead or lag Active power - in Watts (W) Reactive power - in Reactive Volt-Amperes (VARs) Apparent power - in Volt-Amperes (VA) Power factor - as a ratio or percent ...
69 kV to 500 kV INTERCONNECTION REQUIREMENTS FOR
... including technical and operation criteria and processes. In certain cases (such as installation of revenue metering equipment), a review of plans and specifications by BC Hydro may also be required. BC Hydro review of the specifications and detailed plans shall not be construed as confirming or end ...
... including technical and operation criteria and processes. In certain cases (such as installation of revenue metering equipment), a review of plans and specifications by BC Hydro may also be required. BC Hydro review of the specifications and detailed plans shall not be construed as confirming or end ...
Ch9-12
... In a MOS differential pair, there exists a finite differential input voltage to completely switch the current from one transistor to the other, whereas, in a bipolar pair that voltage is infinite. CH 10 Differential Amplifiers ...
... In a MOS differential pair, there exists a finite differential input voltage to completely switch the current from one transistor to the other, whereas, in a bipolar pair that voltage is infinite. CH 10 Differential Amplifiers ...
Electronics 123
... and see the products firsthand, however for your convenience all the products may also be ordered from our website. Electronics123 is a well-established company providing a service to thousands of electronic hobbyists, students and professionals throughout South Africa. ...
... and see the products firsthand, however for your convenience all the products may also be ordered from our website. Electronics123 is a well-established company providing a service to thousands of electronic hobbyists, students and professionals throughout South Africa. ...
Typical ECM/PCM Inputs
... digital signal. This digital signal is sent to the ECM/PCM. Depending on the application, the DC signal may also go to the cruise control system or the speedometer. On later systems the AC signal is typically sent directly to the ECM/PCM. The ECM/PCM converts the AC voltage to a DC signal and then s ...
... digital signal. This digital signal is sent to the ECM/PCM. Depending on the application, the DC signal may also go to the cruise control system or the speedometer. On later systems the AC signal is typically sent directly to the ECM/PCM. The ECM/PCM converts the AC voltage to a DC signal and then s ...
How to Use the IBIS Model
... capture as much practical example material of using IBIS models for Signal Integrity (SI) simulation as the reader may find useful. History and Motivation of IBIS Modeling IBIS is an acronym for “I/O (Input-Output) Buffer Information Specification.” It is a template (standard, data-exchange format, ...
... capture as much practical example material of using IBIS models for Signal Integrity (SI) simulation as the reader may find useful. History and Motivation of IBIS Modeling IBIS is an acronym for “I/O (Input-Output) Buffer Information Specification.” It is a template (standard, data-exchange format, ...
How to Use the IBIS Model
... capture as much practical example material of using IBIS models for Signal Integrity (SI) simulation as the reader may find useful. History and Motivation of IBIS Modeling IBIS is an acronym for “I/O (Input-Output) Buffer Information Specification.” It is a template (standard, data-exchange format, ...
... capture as much practical example material of using IBIS models for Signal Integrity (SI) simulation as the reader may find useful. History and Motivation of IBIS Modeling IBIS is an acronym for “I/O (Input-Output) Buffer Information Specification.” It is a template (standard, data-exchange format, ...
7 AMI 70 en
... OPEN LED is lit (2 seconds). Release button. Set points are retained even after power is removed. To test solenoid, apply power to the “Sol Pwr IN” terminals only. See warning below. WARNING: Do not apply external power to the “Sol Out” terminals. This will cause permanent damage to the unit. CAUTIO ...
... OPEN LED is lit (2 seconds). Release button. Set points are retained even after power is removed. To test solenoid, apply power to the “Sol Pwr IN” terminals only. See warning below. WARNING: Do not apply external power to the “Sol Out” terminals. This will cause permanent damage to the unit. CAUTIO ...
ge energy - GE Industrial Solutions
... hinged-doors housing the fuse-holders, which are solidly connected to high conductivity copper clip-on contacts reinforced by spring steel strips. These clipon contacts plug directly on to the busbars at the plug-in points. For additional safety, two earth-pins are located at the two ends of these b ...
... hinged-doors housing the fuse-holders, which are solidly connected to high conductivity copper clip-on contacts reinforced by spring steel strips. These clipon contacts plug directly on to the busbars at the plug-in points. For additional safety, two earth-pins are located at the two ends of these b ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.