• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Symmetra PX Guide Specifications
Symmetra PX Guide Specifications

... or less at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be true while supporting loads of both a linear or non-linear type. This shall be accomplished with no additional filters, magnetic devic ...
Multi Channel Amplifier Owner`s Manual 570
Multi Channel Amplifier Owner`s Manual 570

... vehicle battery. Confirm that your source unit or other equipment is turned off while connecting the input jacks and speaker terminals. Use only proper car audio insulated 4ga. (or larger) power cable. The +12Volt power cable must be connected with a in-line fuse within 8in from the positive battery ...
FAN7711 Ballast Control Integrated Circuit F AN77
FAN7711 Ballast Control Integrated Circuit F AN77

... Before the lamp is ignited, the lamp impedance is very high. Once the lamp is turned on, the lamp impedance significantly decreases. Since the resonant peak is very high due to the high-resistance of the lamp at the instant of turning on the lamp, the lamp must be driven at higher frequency than the ...
VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä
VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä

... electricity is transferred from producers to customer is called a network. It is very important to control the voltage because the supplier has to convey the highest possible quality to the customer with minimum faults. There are standards for these problems and if a fault occurs, there is a set tim ...
uss dry type transformer
uss dry type transformer

... Forced air cooling, when required, shall increase the self-cooled rating of the transformer by 33 1/3% for units rated 5000 kVA and below and 25% for units 5001 kVA and larger. The FA increase shall be possible with forced cooling without exceeding the specified maximum temperature rise. The additio ...
ENGR 210 Lab 6
ENGR 210 Lab 6

... channels, to display different signals. Oscilloscopes usually have at least two channels so that one can display two waveforms simultaneously ("chop" in which the scope draws a point on channel one and then a point on channel two and then continues to “chop” back and forth while drawing two waveform ...
Fault Analysis of 9-Bus Test System
Fault Analysis of 9-Bus Test System

... choose determines the content of the remainder of this dialog 2.1 Fault in Power System In an electric power system, a fault is any abnormal operation. For example, a short circuit is a fault in which current by passes the normal load. An open-circuit fault occurs if a circuit is interrupted by some ...
Source Resistance Induced Distortion in Op Amps
Source Resistance Induced Distortion in Op Amps

... Unfortunately the input bias current cancellation circuit works well only at very low frequencies; at 1kHz the input resistance is very nonlinear. The distortion from the OP27 is 50 times worse with a 10k source than with a 100Ω source. The LT1124 is a dual low noise precision op amp that uses a dif ...
VLSI Iterative Decoder Design
VLSI Iterative Decoder Design

... CMOS Device Characteristics CMOS Current Mirror Design of Level Shifter through Mirror Circuit Circuit Simulation Delay and Power Analysis Leakage Analysis Comparison Analysis Summary and Discussion ...
Inverter Technology by Panasonic
Inverter Technology by Panasonic

No Slide Title
No Slide Title

... A  uC (0)  uC ()  U S uC (t )  uC ()  [uC (0)  uC ()]e ...
Test of ScannerMAX Saturn 1 with 600Hz Sine
Test of ScannerMAX Saturn 1 with 600Hz Sine

... What follows are scope screen shots of a test of ScannerMAX Saturn 1B with our standard mirrors capable of moving a 3mm beam through 60 degrees optical. Standard tuning was also used. Note that our servo driver has a built-in oscilloscope function and so that is what we are seeing. The yellow trace ...
EX650 Series
EX650 Series

... Remove the test lead probe covers for CAT II 1000V installations. Use the test lead probe covers  for CAT III 600V installations.   Do not measure voltages greater than 750VAC or 1000VDC.  CAUTION: When connecting the test leads to the circuit or device under test, connect the  black lead before the ...
PAM3110 Description Pin Assignments
PAM3110 Description Pin Assignments

... 4.7µF minimum value capacitor from VO to GND is also required. To improve transient response, noise rejection, and ripple rejection, an additional 1 0μF or larger, low ESR capacitor is recommended at the output. A higher-value, low ESR output capacitor may be necessary if large, fast-rise-time load ...
AD1671 Complete 12-Bit 1.25 MSPS Monolithic A/D Converter
AD1671 Complete 12-Bit 1.25 MSPS Monolithic A/D Converter

... voltage levels in successive channels and sampling inputs at frequencies up to and beyond the Nyquist rate. The AD1671 provides both reference output and reference input pins, allowing the on-board reference to serve as a system reference. An external reference can also be chosen to suit the dc accu ...
AN203: 8-bit MCU Printed Circuit Board Design Notes
AN203: 8-bit MCU Printed Circuit Board Design Notes

... In-series inductance provides the most effective isolation from high-frequency noise. The inductance should be placed between the analog and digital power supply circuits, with the analog circuit closest to the voltage regulator. If, due to cost or lack of availability, it is not practical to use an ...
LT1505 - Constant-Current/Voltage High Efficiency Battery Charger
LT1505 - Constant-Current/Voltage High Efficiency Battery Charger

... Limit Amplifier CL1. The threshold is set at 92mV. When used to limit input current, a filter is needed to filter out the 200kHz switching noise. (LT1505-1: No Connection.) CLN (Pin 10): LT1505: Negative Input to the Input Current Limit Amplifier CL1. When used, both CLP and CLN should be connected ...
GMC Yukon and Sierra, Chevrolet Tahoe and Silverado, and
GMC Yukon and Sierra, Chevrolet Tahoe and Silverado, and

... The GMC Yukon and Sierra, Chevrolet Tahoe and Silverado, and Cadillac Escalade Two-mode vehicles are gasolineelectric Hybrid SUVs/trucks that use up to 25 percent less fuel overall and 40% less fuel in the city, than the nonHybrid GMC Yukon and Sierra, Chevrolet Tahoe and Silverado, and Cadillac Esc ...
AN2834
AN2834

... But with a 40 mV peak-to-peak ripple in the power supply, the converted value becomes (1/3.34) × 4095 = 4CAh (with VREF+ at its peak). Error = 4D9 – 4CA = 15 LSB The SMPS (switch-mode power supply) normally has internal fast-switching power transistors. This introduces high-frequency noise in the ou ...
Fire alarm control panel Manual
Fire alarm control panel Manual

... Should an alarm condition be initiated by a detector or a manual call point, Twin red “FIRE” led’s indicate in that zone. Internal buzzer will sound and two sounder circuits will activate. Sounder circuits can be silenced or recalled at any time during the period between fire detection and system re ...
Document
Document

systems for street lighting control power reduction
systems for street lighting control power reduction

... and Krakow), but also in Estonia, Romania, Lithuania and Latvia. ...
2SK3796 N-Channel JFET 30V, 0.6 to 3.0mA
2SK3796 N-Channel JFET 30V, 0.6 to 3.0mA

... of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent-Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no wa ...
S-75L00ANC - SII Semiconductor Corporation
S-75L00ANC - SII Semiconductor Corporation

... Power Dissipation of Package (When Mounted on Board) ...
AC versus DC Measurement Methods for Low
AC versus DC Measurement Methods for Low

... the same magnitude—10MΩ. This means that half of the current intended for the DUT will instead flow through the instrument input, and the measured voltage will be in error by 50%. Even with careful subtraction schemes, it is not practical to achieve ±1% accuracy when measuring a DUT with a resistanc ...
< 1 ... 787 788 789 790 791 792 793 794 795 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.