• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Testing Lighting Circuits
Testing Lighting Circuits

... Figure 11 illustrates a 2 Gang 2 Way Plate Switch. Two gang one way switches may not always be available, in this event two gang two way plate switches are generally used. This also applies to 3, 4 and 6 Gang switches. ...
Lessons In Electric Circuits, Volume IV -- Digital
Lessons In Electric Circuits, Volume IV -- Digital

... are needed when negative equivalents of whole numbers are required. Irrational numbers are numbers that cannot be exactly expressed as the ratio of two integers, and the ratio of a perfect circle’s circumference to its diameter (π) is a good physical example of this. The non-integer quantities of vo ...
Audio Power Amplifier Design Handbook, Fifth Edition
Audio Power Amplifier Design Handbook, Fifth Edition

IS 13947-5-2 (2004): Low-Voltage Switchgear and Controlgear, Part
IS 13947-5-2 (2004): Low-Voltage Switchgear and Controlgear, Part

t170 commercial thermostat
t170 commercial thermostat

... • Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE. • To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full thermostat operat ...
Impact of VSWR on the Uncertainty Analysis of Harmonics
Impact of VSWR on the Uncertainty Analysis of Harmonics

... and switching capabilities. The specifications of a modern calibrator may include: 1) AC/DC voltage amplitude, 2) AC/DC current amplitude, 3) voltage measurement, 4) frequency/period, 5) leveled sine amplitude, 6) edge rise time, 7) aberration, 8) harmonics, 9) pulse width, 10) jitter, 11) skew, 12) ...
SEL-734 Quick
SEL-734 Quick

... QuickSet automatically hides unavailable configuration settings and flags invalid configuration settings at the bottom of the screen. Right-click on any setting for the previous or default value. ...
E2E/E2E2 - OMRON – Automação Industrial
E2E/E2E2 - OMRON – Automação Industrial

... Note 1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface condition (the PLC’s ON voltage, for example) when connecting the Proximity Sensor to a load. 2. The standard cable length is 300 mm. Models are also available with 500 ...
electric service requirements
electric service requirements

this PDF file - Radio Electronics, Computer Science, Control
this PDF file - Radio Electronics, Computer Science, Control

STAR3_User Manual Eng.FH11 - elcontrol
STAR3_User Manual Eng.FH11 - elcontrol

... Use the SEL key to select a digit or a setting. Use the SET key to adjust it. The setup can be protected with a password (see next chapter) ·Page S1 Programming the Primary and Secondary ratio of a PT. Use a ratio equal to 1 ( e.g. 100/100) in case of direct measurement without voltage transformer i ...
isl28006 - ISL28006 - Micropower, Rail to Rail Input Current Sense
isl28006 - ISL28006 - Micropower, Rail to Rail Input Current Sense

... voltage is usually much higher than the amplifier supply voltage. The device can be used to sense voltages as high as 28V when operating from a supply voltage as low as 2.7V. The micropower ISL28006 consumes only 50µA of supply current when operating from a 2.7V to 28V supply. ...
Guidelines for electrical design and interface
Guidelines for electrical design and interface

8.0 ELECTRIC POWER
8.0 ELECTRIC POWER

... regulatory guidelines and industry standards and found it to be consistent with Section 8.1 of NUREG-0800 with the exception of the information discussed below. VCS COL FSAR Table 8.1-201, 1b indicated that RG 1.155 is not applicable to VCSNS. This item was deemed as standard among COL applications ...
Instruction Book M-3410A Intertie/Generator Protection Relay
Instruction Book M-3410A Intertie/Generator Protection Relay

... contacts and output contacts, storing up to 120 cycles of data. The total record length is configured for one or two partitions. A programmable post trigger delay (5 to 95%) is incorporated to capture breaker operation. The oscillograph is triggered either remotely using the serial interface, or des ...
On-Chip Transient Detection Circuit for System
On-Chip Transient Detection Circuit for System

... By using the HSPICE, the circuit operation of the proposed transient detection circuit to sense fast electrical transients can be analyzed in detail. The sensitivity of the transient detection circuit can be analyzed by changing the coupling capacitors or adjusting the device W/L ratios in the latch ...
Model No. KX-TG1711MEB KX-TG1712MEB KX
Model No. KX-TG1711MEB KX-TG1712MEB KX

... • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work. 1. When repair services are provided, neither the products nor their parts or members shall be rem ...
Standard Duct Heaters Open Coil
Standard Duct Heaters Open Coil

... ● 5. All heaters shall be furnished with a disc type, automatic reset thermal cutout for primary overtemperature protection. All heaters shall also be furnished with disc type, load carrying manual reset thermal cutouts, factory wired in series with heater stages for secondary protection. Heat limit ...
Standard Duct Heaters Open Coil
Standard Duct Heaters Open Coil

... Allows control circuit to be obtained from source outside the heater or, when line voltage is equal to control voltage, directly from power lines within the heater. ...
Dual, Low-Noise Variable-Gain Amplifier with Preamp (Rev. D)
Dual, Low-Noise Variable-Gain Amplifier with Preamp (Rev. D)

... common to both channels of the VCA2615. In addition, the overall gain can be switched between a 0dB and +6dB postgain, allowing the user to optimize the output swing of VCA2615 for a variety of high-speed Analog-to-Digital Converters (ADCs). As a means to improve system overload recovery time, the V ...
dual voltage refrigerators 120 volts ac and 12/24 volts dc
dual voltage refrigerators 120 volts ac and 12/24 volts dc

... The cooling unit of your Norcold refrigerator makes heat. This heat must be removed quickly and efficiently in order for the refrigerator to have its maximum cooling performance. When the refrigerator is in an enclosed space, the temperature within the space will rise quickly and will reduce the coo ...
Ch2 Basic Analysis Methods to Circuits
Ch2 Basic Analysis Methods to Circuits

... – Analysis of circuits using node or loop analysis requires solutions of systems of linear equations. – These equations can usually be written by inspection of the circuit. ...
NVT2003/04/06 Bidirectional voltage-level translator for open
NVT2003/04/06 Bidirectional voltage-level translator for open

Sepam™ Series 40 Protective Relays
Sepam™ Series 40 Protective Relays

Bipolar Junction Transistor
Bipolar Junction Transistor

... base and collector. As shown in Fig. 57.1 (a) junction transistor is simply a sandwich of one type of semiconductor material between two layers of the other type. Fig. 57.1 (a) shows a layer of N-type material sandwiched between two layers of P-type material. It is described as a PNP transistor. Fig ...
< 1 ... 65 66 67 68 69 70 71 72 73 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report