MAX5394 Single, 256-Tap Volatile, SPI, Low-Voltage Linear Taper Digital Potentiometer General Description
... linear taper digital potentiometer offers three end-toend resistance values of 10kΩ, 50kΩ, and 100kΩ. Potentiometer terminals are independent of supply for voltages up to 5.25V with single-supply operation from 1.7V to 5.5V (charge pump enabled). User-controlled shutdown modes allow the H, W, or L t ...
... linear taper digital potentiometer offers three end-toend resistance values of 10kΩ, 50kΩ, and 100kΩ. Potentiometer terminals are independent of supply for voltages up to 5.25V with single-supply operation from 1.7V to 5.5V (charge pump enabled). User-controlled shutdown modes allow the H, W, or L t ...
x - Research Commons@Waikato
... This research presents three works all related by the subject of third-order distortion reduction in nonlinear circuits. Each one is a novel extension to previous work in that branch of electronics literature. All three follow the procedure of presenting a novel algebraic proof and following up with ...
... This research presents three works all related by the subject of third-order distortion reduction in nonlinear circuits. Each one is a novel extension to previous work in that branch of electronics literature. All three follow the procedure of presenting a novel algebraic proof and following up with ...
MAX16056–MAX16059 125nA Supervisory Circuits with Capacitor- Adjustable Reset and Watchdog Timeouts General Description
... mode and extended mode. In normal mode (Figure 2), the watchdog timeout period is determined by the value of the capacitor connected between SWT and ground. In extended mode (Figure 3), the watchdog timeout period is multiplied by 128. For example, in extended mode, a 0.33µF capacitor gives a watchd ...
... mode and extended mode. In normal mode (Figure 2), the watchdog timeout period is determined by the value of the capacitor connected between SWT and ground. In extended mode (Figure 3), the watchdog timeout period is multiplied by 128. For example, in extended mode, a 0.33µF capacitor gives a watchd ...
Institutionen för systemteknik Department of Electrical Engineering
... A/D signal requirements . . . . . . . . . . Multiplexer signal distribution . . . . . . Multiplexer pin requirements . . . . . . . GPIO subsystem pin requirements . . . . ...
... A/D signal requirements . . . . . . . . . . Multiplexer signal distribution . . . . . . Multiplexer pin requirements . . . . . . . GPIO subsystem pin requirements . . . . ...
Controlled Power, LLC 38kV Metal Clad Switchgear Guide
... cover plates or doors. The voltage and current transformer secondary wiring runs in high voltage compartments shall be shielded or routed in metal conduit. Removable cover plates shall be provided for access to buses, voltage and current transformers, low voltage wires, etc. The relay panels or door ...
... cover plates or doors. The voltage and current transformer secondary wiring runs in high voltage compartments shall be shielded or routed in metal conduit. Removable cover plates shall be provided for access to buses, voltage and current transformers, low voltage wires, etc. The relay panels or door ...
ADM1026JST
... 5. Total analog monitoring cycle time is nominally 273 ms, made up of 18 ms 11.38 ms measurements on analog input and internal temperature channels, and 2 ms 34.13 ms measurements on external temperature channels. 6. The total fan count is based on two pulses per revolution of the fan tachometer ...
... 5. Total analog monitoring cycle time is nominally 273 ms, made up of 18 ms 11.38 ms measurements on analog input and internal temperature channels, and 2 ms 34.13 ms measurements on external temperature channels. 6. The total fan count is based on two pulses per revolution of the fan tachometer ...
RM100 MooreHawke ROUTE-MASTER Fieldbus
... significant advantage over “current-limiting” designs on competing units which hold a fault permanently on the segment at a higher-than-normal current level. This often results in segment failure by overloading the segment power supply. With removal of the short, the spur is automatically reconnecte ...
... significant advantage over “current-limiting” designs on competing units which hold a fault permanently on the segment at a higher-than-normal current level. This often results in segment failure by overloading the segment power supply. With removal of the short, the spur is automatically reconnecte ...
Document
... The junction gate field-effect transistor (JFET or JUGFET) is the simplest type of field-effect transistor. It can be used as an electronicallycontrolled switch or as a voltage-controlled resistance. Electric charge flows through a semiconducting channel between "source" and "drain" terminals. By ap ...
... The junction gate field-effect transistor (JFET or JUGFET) is the simplest type of field-effect transistor. It can be used as an electronicallycontrolled switch or as a voltage-controlled resistance. Electric charge flows through a semiconducting channel between "source" and "drain" terminals. By ap ...
Volume 5 Tab 5
... continuous currents from 1 to 150 A and does not require any supply voltage, as the power required is induced from the monitored conductor. The output is a non-polarity-sensitive solidstate contact for switching AC and DC circuits up to 240 Vac/Vdc. This switch also includes an LED indicating two st ...
... continuous currents from 1 to 150 A and does not require any supply voltage, as the power required is induced from the monitored conductor. The output is a non-polarity-sensitive solidstate contact for switching AC and DC circuits up to 240 Vac/Vdc. This switch also includes an LED indicating two st ...
Tests to determine short characteristics of GlueX Solenoid coils one
... sub coil in coil 1 that is shorted, the short location at 29 turns in from the negative lead is exactly the midpoint of the first double pancake .Similarly in coil 3 the short is ~ 12 turns in from the negative lead , exactly half way into the first double pancake. This location is common to both co ...
... sub coil in coil 1 that is shorted, the short location at 29 turns in from the negative lead is exactly the midpoint of the first double pancake .Similarly in coil 3 the short is ~ 12 turns in from the negative lead , exactly half way into the first double pancake. This location is common to both co ...
Electricity 15
... Current will only flow in the earth wire if there has been a short circuit and electricity has been lost from the intended pathway, flowing to earth down the earth wire. ...
... Current will only flow in the earth wire if there has been a short circuit and electricity has been lost from the intended pathway, flowing to earth down the earth wire. ...
SC1500 Service Manual
... To Access the Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To Access a Submenu from the Main Menu . . . . . . . . . . . . . . . . . . . . . . To Change a Programmable Option in a Submenu . . . . . . . . . . ...
... To Access the Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To Access a Submenu from the Main Menu . . . . . . . . . . . . . . . . . . . . . . To Change a Programmable Option in a Submenu . . . . . . . . . . ...
SC1500 Service Manual
... To Access the Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To Access a Submenu from the Main Menu . . . . . . . . . . . . . . . . . . . . . . To Change a Programmable Option in a Submenu . . . . . . . . . . ...
... To Access the Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To Access a Submenu from the Main Menu . . . . . . . . . . . . . . . . . . . . . . To Change a Programmable Option in a Submenu . . . . . . . . . . ...
Solution - University of California, Berkeley
... In measuring tp, you must choose Vdd/2 instead of (Voh+Vol)/2. Therefore the H → L transition begins at Vout = Voh and ends at Vout = Vdd/2 = 1.25. Similarly, the L → H transition begins at Vout=Vol and ends at Vout=Vdd/2. Let’s find the equivalent resistance at the start and end points respectively ...
... In measuring tp, you must choose Vdd/2 instead of (Voh+Vol)/2. Therefore the H → L transition begins at Vout = Voh and ends at Vout = Vdd/2 = 1.25. Similarly, the L → H transition begins at Vout=Vol and ends at Vout=Vdd/2. Let’s find the equivalent resistance at the start and end points respectively ...
Quad-Core Intel® Xeon® Processor 5400 Series
... PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or character ...
... PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or character ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.