• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
V = IR
V = IR

Experiment 10: Inverting Amplifier
Experiment 10: Inverting Amplifier

RM1200 - Mobat-USA
RM1200 - Mobat-USA

... • With Failsoft operation, duel power supplies and parallel amplifier modules maintain ...
V = IR
V = IR

Remote monitoring of transformer or generator health over internet
Remote monitoring of transformer or generator health over internet

JN3616501653
JN3616501653

BC4102392396
BC4102392396

... the compensator to filter the high frequency switching noise of the voltage at PCC. The STATCOM used in distribution systems is called DSTACOM (DistributionSTACOM) and its configuration is the same, but with small modifications. It can exchange both active and reactive power with the distribution sy ...
Evaluates:  MAX17112 MAX17112 Evaluation Kit General Description Features
Evaluates: MAX17112 MAX17112 Evaluation Kit General Description Features

... with a 4.5V input. The step-up switching regulator output voltage can be adjusted from VIN to 20V by changing the values of the feedback resistors (see the Evaluating Other Output Voltages section). The MAX17112 EV kit can operate from a 2.6V to 5.5V input supply. When input voltage is less than 4.5 ...
electronic stick for blind people
electronic stick for blind people

... electronic stick and giving the alarm • This will assist the blind persons during the walk and provides an alarm if any hurdle is detected with-In the set range • This system mainly consists of a regulated power supply, IR transmitter, IR receiver, control circuit and the output driver circuit ...
DN505 - Dual Controller Provides 2μs Step
DN505 - Dual Controller Provides 2μs Step

High Voltage on Ships,Safety,Equipment Testing
High Voltage on Ships,Safety,Equipment Testing

Ohm`s Law and Basic Circuit Theory – Answer Sheet
Ohm`s Law and Basic Circuit Theory – Answer Sheet

... different quantity as the subject of the equation. Write each of these in the space provided. ...
AC Current transducer AP
AC Current transducer AP

... Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and ope ...
Sorensen 36 kW - 240 kW HPX Series 10 - 1000 V 45
Sorensen 36 kW - 240 kW HPX Series 10 - 1000 V 45

... The HPX Series features two modes in one: Automatic constant voltage and constant current mode crossover with protection against hazardous faults. Remote Shutdown (S/D) Interlock provides various external output shutdown capability in case hazardous faults occur. Other features such as External Anal ...
ULN2003,04APG/AFWG
ULN2003,04APG/AFWG

... • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA’s written permission, reproduction is permissible only if reproduction is without alteration/omission. • Though TOSHIBA works continually to improve Product’s quality and ...
Chapter 7 Review
Chapter 7 Review

... • When you talk about a battery's voltage, you are referring to: • amount of energy per unit of charge. ...
EEE 110-5257
EEE 110-5257

... controllers. Compared to STATCOM, DSTATCOM have significantly lower rated power and in consequence, faster power electronics switches, thus the PWM carries frequency used in a distribution controller can be much higher than in a FACTS controller. It has a substantial positive impact on the dynamics ...
The Field Effect Transistor
The Field Effect Transistor

... Using the same transistor, build the circuit below with a power supply for VDD and a signal generator for the variable input voltages, as shown in Figure 3. For a good operating point, the drain voltage should be between 3 V and 7 V. Measure the quiescent drain voltage for your circuit. (The AC sign ...
Crystal(R) AC Power Supplies: 60, 100, 120, 150, and 180 kW
Crystal(R) AC Power Supplies: 60, 100, 120, 150, and 180 kW

... Crystal power supplies offer a wide output impedance range and a stable resonant network design, enabling them to run processes from full reactive to full metallic. They suit most any ...
Type ME-7 Voltage Transformer
Type ME-7 Voltage Transformer

RC Time Constant
RC Time Constant

... let's say the low potential = 0, the high potential = 1. During the transients of the voltage, we are neither here nor there, but our electronic circuitry typically will interpret a potential < U/2 as 0, > U/2 as 1. That simply means that the time it takes for a signal to travel through a wire with ...
AE4301167171
AE4301167171

TD62008APG,TD62008AFG - Toshiba America Electronic
TD62008APG,TD62008AFG - Toshiba America Electronic

... • This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA’s written permission, reproduction is permissible only if reproduction is without alteration/omission. • Though TOSHIBA works continually to improve Product’s quality and ...
Catalogue electronic modules and components
Catalogue electronic modules and components

... Thanks to its extremely compact design, the ESM electronic module can be installed in very restricted space. The ESM features a central bore for screw fixing inside the terminal box. It can also be installed by using an adhesive pad. ...
AND8039/D The One−Transistor Forward Converter
AND8039/D The One−Transistor Forward Converter

< 1 ... 2466 2467 2468 2469 2470 2471 2472 2473 2474 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report