Owner`s Manual - SpeakEasy Pedals
... PROOF – The Proof knob controls the amount of dynamic headroom in the main distortion stage. As this control is increased, the amount of distortion becomes a dynamic function of how hard you play. Moderate settings (near 12 o’clock) can emulate the feel of a tube amplifier with an overdriven output ...
... PROOF – The Proof knob controls the amount of dynamic headroom in the main distortion stage. As this control is increased, the amount of distortion becomes a dynamic function of how hard you play. Moderate settings (near 12 o’clock) can emulate the feel of a tube amplifier with an overdriven output ...
RESET MAX1947 Low Input/Output Voltage Step-Up DC-DC Converter with
... Active-Low Push-Pull Reset Output. RESET goes high 75ms (min) after the output voltage has exceeded 90% of its final value. The RESET output is valid for output voltages as low as 0.9V. RESET is driven low in shutdown. Ground. Connect to exposed paddle. ...
... Active-Low Push-Pull Reset Output. RESET goes high 75ms (min) after the output voltage has exceeded 90% of its final value. The RESET output is valid for output voltages as low as 0.9V. RESET is driven low in shutdown. Ground. Connect to exposed paddle. ...
Research Article Matrix Converter Based Unified Power Quality
... the matrix converter output terminals to the load side through series transformer and the input side of matrix converter is connected to the supply side with step up transformer. So a matrix converter injects the compensation voltage on the load-side, so it is possible to mitigate the voltage sag/sw ...
... the matrix converter output terminals to the load side through series transformer and the input side of matrix converter is connected to the supply side with step up transformer. So a matrix converter injects the compensation voltage on the load-side, so it is possible to mitigate the voltage sag/sw ...
Data Sheet - System Sensor Canada
... • Compatible with System Sensor synchronization protocol • 3 programmable Form C relays • 7.0 amps total 24 VDC output current ...
... • Compatible with System Sensor synchronization protocol • 3 programmable Form C relays • 7.0 amps total 24 VDC output current ...
city of surrey electrical inspection report for primary unit substations
... Ground pad location and identification (each conductor connected to ground pad to be identified in a permanent manner) A Field Review report from the design engineer is to be submitted indicating the installation has been inspected, all test reports have been reviewed, and the installation is now re ...
... Ground pad location and identification (each conductor connected to ground pad to be identified in a permanent manner) A Field Review report from the design engineer is to be submitted indicating the installation has been inspected, all test reports have been reviewed, and the installation is now re ...
301 LM301
... Case temperature for 60 seconds: FK package Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds ...
... Case temperature for 60 seconds: FK package Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds ...
Datasheet Atto D4
... DIN 43864 standards. The two outputs are factory set to the transmission of pulses proportional to the Active energy and the Reactive energy (pulse weight and length are user programmable). The outputs may be alternatively configured as outputs of the internal alarms (see Alarms) or as remote output ...
... DIN 43864 standards. The two outputs are factory set to the transmission of pulses proportional to the Active energy and the Reactive energy (pulse weight and length are user programmable). The outputs may be alternatively configured as outputs of the internal alarms (see Alarms) or as remote output ...
Classification of transformers according to turn ratio
... Classification of transformers according to their function: 1- Power transformer 2- Distribution transformer 3- Measuring transformers A)voltage transformer B) current transformer 4-Autotransformer- Tapped autotransformer ...
... Classification of transformers according to their function: 1- Power transformer 2- Distribution transformer 3- Measuring transformers A)voltage transformer B) current transformer 4-Autotransformer- Tapped autotransformer ...
Grob Basic Electronics Chapter 4 SERIES CIRCUITS
... voltage drops across the individual resistances. Total power is equal to the sum of the power dissipated by each resistance. www.itcafe.741.com ...
... voltage drops across the individual resistances. Total power is equal to the sum of the power dissipated by each resistance. www.itcafe.741.com ...
B165-07006
... capacitor unit failure when the compensated voltage differential or impedance change quantity increases beyond a threshold. It then reduces outage time by pinpointing the smallest affected area within the bank. Because it is easily configured to permit the nulling of inherent bank unbalance, the r ...
... capacitor unit failure when the compensated voltage differential or impedance change quantity increases beyond a threshold. It then reduces outage time by pinpointing the smallest affected area within the bank. Because it is easily configured to permit the nulling of inherent bank unbalance, the r ...
abstract - KFUPM Faculty List
... appropriate for a dc output of 5 V. This can be achieved with a 15:1 turns ratio. I In addition to providing the appropriate sinusoidal amplitude for the dc power supply, the power transformer provides electrical isolation between the electronic equipment and the power-line circuit. This isolation m ...
... appropriate for a dc output of 5 V. This can be achieved with a 15:1 turns ratio. I In addition to providing the appropriate sinusoidal amplitude for the dc power supply, the power transformer provides electrical isolation between the electronic equipment and the power-line circuit. This isolation m ...
MAX17067 Low-Noise Step-Up DC-DC Converter General Description Features
... and the inductor’s DC current rating should exceed IIN(DC,MAX). For good efficiency, choose an inductor with less than 0.1Ω series resistance. Considering the application circuit in Figure 4, the maximum load current (IMAIN(MAX)) is 250mA with a 9V output and a typical input voltage of 3.3V. Choosin ...
... and the inductor’s DC current rating should exceed IIN(DC,MAX). For good efficiency, choose an inductor with less than 0.1Ω series resistance. Considering the application circuit in Figure 4, the maximum load current (IMAIN(MAX)) is 250mA with a 9V output and a typical input voltage of 3.3V. Choosin ...
linear circuit analysis
... • Practical inductors satisfy the characteristics approximately. One of the main limitation is resistance of windings. • For a practical resistor, only when L di/dt >> Ri, be regarded as ideal. ...
... • Practical inductors satisfy the characteristics approximately. One of the main limitation is resistance of windings. • For a practical resistor, only when L di/dt >> Ri, be regarded as ideal. ...
PWM for DC motor driver circuit
... 1) level and a low logic (binary 0) level, where high logic has a positive voltage and low logic has zero voltage. Figure 2 is an example. Notice that, here the square wave alternates between 5V and 0V. Also notice that the square waves spends a value of time Δt on both high and low logic This time ...
... 1) level and a low logic (binary 0) level, where high logic has a positive voltage and low logic has zero voltage. Figure 2 is an example. Notice that, here the square wave alternates between 5V and 0V. Also notice that the square waves spends a value of time Δt on both high and low logic This time ...
L4 series and parallel resistors
... Measure the total current I flowing in the circuit and the currents flowing in each branch with the ammeter. Place the results in Excel worksheet. Calculate the each and total resistance from Ohms Law. Compare this to the theoretical formulae calculation to confirm formulae for resistors in parallel ...
... Measure the total current I flowing in the circuit and the currents flowing in each branch with the ammeter. Place the results in Excel worksheet. Calculate the each and total resistance from Ohms Law. Compare this to the theoretical formulae calculation to confirm formulae for resistors in parallel ...
Tools and Technical Items
... Battery charger, solar powered. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... Battery charger, solar powered. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
IKI PTR-II
... The IKI Pulse Train Reader is a list mode acquisition system for neutron coincidence counting. It consists of an external hardware unit and a user-friendly windows software package. Measured data are transferred to the PC and written to hard disk. The recorded pulse train, can be evaluated with diff ...
... The IKI Pulse Train Reader is a list mode acquisition system for neutron coincidence counting. It consists of an external hardware unit and a user-friendly windows software package. Measured data are transferred to the PC and written to hard disk. The recorded pulse train, can be evaluated with diff ...
Amplifier Construction
... http://www.bodziosoftware.com.au/Power_Amplifiers.pdf ).The original version of this stereo amplifier included bass and treble active tone controls and input voltage follower for each channel, both using OPAMPs. In addition, there was also a 10-LED output power indicator for each channel. I have str ...
... http://www.bodziosoftware.com.au/Power_Amplifiers.pdf ).The original version of this stereo amplifier included bass and treble active tone controls and input voltage follower for each channel, both using OPAMPs. In addition, there was also a 10-LED output power indicator for each channel. I have str ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.