Document
... same material around the same core with the same length and the same number of turns. The equation for inductance is L ...
... same material around the same core with the same length and the same number of turns. The equation for inductance is L ...
TESTING OF ISOLATORS AND CIRCUIT BREAKERS Isolator: Off
... If it is not suitably designed its failure may cause a lengthy and costly outage. Therefore, it is very important to be cautious while designing its insulation, so that it can withstand transient over voltage both due to switching and lightning. The high voltage testing of transformers is, the ...
... If it is not suitably designed its failure may cause a lengthy and costly outage. Therefore, it is very important to be cautious while designing its insulation, so that it can withstand transient over voltage both due to switching and lightning. The high voltage testing of transformers is, the ...
MAX16977 36V, 2A, 2.2MHz Step-Down Converter with Low Operating Current General Description
... The MAX16977 is a constant-frequency, current-mode, automotive buck converter with an integrated high-side switch. The device operates with input voltages from 3.5V to 36V and tolerates input transients up to 42V. During undervoltage events, such as cold-crank conditions, the internal pass device ma ...
... The MAX16977 is a constant-frequency, current-mode, automotive buck converter with an integrated high-side switch. The device operates with input voltages from 3.5V to 36V and tolerates input transients up to 42V. During undervoltage events, such as cold-crank conditions, the internal pass device ma ...
Fuzzy Incremental Conductance for Maximum Power Point
... operate at the MPP is called maximum power point tracking (MPPT) which typically employs a dc-dc converter that connects the PV system to the load [4]. As temperature or solar irradiation changes, the MPP will shift accordingly. Similarly, any change in the load will also cause the MPP to move the p ...
... operate at the MPP is called maximum power point tracking (MPPT) which typically employs a dc-dc converter that connects the PV system to the load [4]. As temperature or solar irradiation changes, the MPP will shift accordingly. Similarly, any change in the load will also cause the MPP to move the p ...
Transient Suppression: Switching Power Supplies
... Transient Suppression: Switching Power Supplies Application Note Although the concepts stated are universal, this application note was written specifically for Interpoint products. Power line transient requirements are a subject which should be addressed at the beginning of a project, not in the lat ...
... Transient Suppression: Switching Power Supplies Application Note Although the concepts stated are universal, this application note was written specifically for Interpoint products. Power line transient requirements are a subject which should be addressed at the beginning of a project, not in the lat ...
“Real” Transformer
... Define ZeqP = The “equivalent impedance” with all parameters referred to the primary ...
... Define ZeqP = The “equivalent impedance” with all parameters referred to the primary ...
DMS-EB - Murata Power Solutions
... meters. The adjustment range of both pots is very narrow. See the applicable product data sheet for more information on each meter’s calibration potentiometers. 7. Input Configurations: The DMS-EB is supplied with SG5 closed. SG5 connects J1, pin 2 (LO) to power return J1, pin 6 (GND) and configures t ...
... meters. The adjustment range of both pots is very narrow. See the applicable product data sheet for more information on each meter’s calibration potentiometers. 7. Input Configurations: The DMS-EB is supplied with SG5 closed. SG5 connects J1, pin 2 (LO) to power return J1, pin 6 (GND) and configures t ...
DTD123YK
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
... shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability th ...
Electric current
... 10. B When one light goes out, the rest stay on in a _____ circuit. 11. A When one light goes out, so do the rest in a ____ circuit. 12. C Current and resistance are inversely related. 13. A The individual resistors add up to the total resistance. 14. D Light bulbs supply current. 15. B The current ...
... 10. B When one light goes out, the rest stay on in a _____ circuit. 11. A When one light goes out, so do the rest in a ____ circuit. 12. C Current and resistance are inversely related. 13. A The individual resistors add up to the total resistance. 14. D Light bulbs supply current. 15. B The current ...
the S1500 Technical Sheet in PDF format
... bridged or parallel (daisy chain) operation. In stereo mode, it shall deliver a minimum of 750 watts into loads of 4 ohms each with both channels operating. In mono bridge mode, it shall deliver a minimum of 1500 watts into an 8 ohm load. It shall be cooled by two temperature sensitive speed-control ...
... bridged or parallel (daisy chain) operation. In stereo mode, it shall deliver a minimum of 750 watts into loads of 4 ohms each with both channels operating. In mono bridge mode, it shall deliver a minimum of 1500 watts into an 8 ohm load. It shall be cooled by two temperature sensitive speed-control ...
PDF/186 kB - Bachmann electronic GmbH
... the analysis of the data from spatially separated measurement and protection devices. The GMP232 is fully integrated in the Bachmann SolutionCenter. Configurations can be created simply and stored for later reuse. Both the measured channel values and also the derived values are made available direct ...
... the analysis of the data from spatially separated measurement and protection devices. The GMP232 is fully integrated in the Bachmann SolutionCenter. Configurations can be created simply and stored for later reuse. Both the measured channel values and also the derived values are made available direct ...
Transmitters & Receivers
... RF Earths for antennas are often separate - consider earth stakes etc. Modern Gas & Water Pipes can give high resistance earth. AM/SSB can be rectified/detected easily, so is most prone to cause ...
... RF Earths for antennas are often separate - consider earth stakes etc. Modern Gas & Water Pipes can give high resistance earth. AM/SSB can be rectified/detected easily, so is most prone to cause ...
Transil™, transient voltage surge suppressor
... This is information on a product in full production. ...
... This is information on a product in full production. ...
RFVC1831 数据资料DataSheet下载
... Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional op ...
... Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional op ...
Thermonuclear Power Plant Model
... Oil circuit breakers have a steel container and their moving contacts are immersed is insulating oil. When a fault occurs, a spring is released, and the contacts are opened. An electric arc is produced, which volatilizes the oil around the contacts, producing a turbulence that renews the oil around ...
... Oil circuit breakers have a steel container and their moving contacts are immersed is insulating oil. When a fault occurs, a spring is released, and the contacts are opened. An electric arc is produced, which volatilizes the oil around the contacts, producing a turbulence that renews the oil around ...
ground fault neutralizer
... Figure 2 A modern fast tuning solid core arc suppression coil (right hand of picture) forming the high voltage part of the GFN system The arc suppression coil forms a parallel resonant circuit with the phase-to-ground capacitive leakage (Co) of the network. By this resonant circuit the source impeda ...
... Figure 2 A modern fast tuning solid core arc suppression coil (right hand of picture) forming the high voltage part of the GFN system The arc suppression coil forms a parallel resonant circuit with the phase-to-ground capacitive leakage (Co) of the network. By this resonant circuit the source impeda ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.