• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Magnetron Theory of Operation
Magnetron Theory of Operation

... frequency vs. time during the period following initial turn on is called the "Thermal Drift" curve. Generally speaking, the maximum drift occurs during the first few minutes after turn on, and slowly approaches equilibrium over a period ranging from 10 to 30 minutes depending upon the structure mass ...
Evaluation Board User Guide UG-290
Evaluation Board User Guide UG-290

... When connecting the clock and analog source, use clean signal generators with low phase noise, such as the Rohde & Schwarz SMA or HP 8644B signal generators or an equivalent. Use a 1 meter, shielded, RG-58, 50 Ω coaxial cable for connecting to the evaluation board. Enter the desired frequency and am ...
74HC(T) - Nexperia
74HC(T) - Nexperia

... The 74HC123; 74HCT123 are dual retriggerable monostable multivibrators with output pulse width control by three methods: 1. The basic pulse is programmed by selection of an external resistor (REXT) and capacitor (CEXT). 2. Once triggered, the basic output pulse width may be extended by retriggering ...
PDF - This Chapter
PDF - This Chapter

... This is a positive ground system; make sure to connect the positive lead to the +RTN terminal and the negative lead to the -48V terminal. Using the wrench, attach the positive and negative cable pairs to each terminal block on the first power shelf (Power A). Start with PM0 (located on the right sid ...
with 1
with 1

- UK Power Distribution Limited
- UK Power Distribution Limited

... 2.24 Measurement Class C, E or CVA charges apply to Exit/Entry Points where HH metering, or an equivalent meter, is used for Settlement purposes. 2.25 Measurement Class D charges apply to Exit Points deemed to be suitable as Unmetered Supplies as permitted in the Electricity (Unmetered Supply) Regul ...
A MULTI-DIMENSIONAL SPREAD SPECTRUM TRANSCEIVER Saurabh Sinha Philosophiae Doctor (Electronic Engineering)
A MULTI-DIMENSIONAL SPREAD SPECTRUM TRANSCEIVER Saurabh Sinha Philosophiae Doctor (Electronic Engineering)

... achieving higher power efficiency. ...
5050-0344 Rev H PRC2000_SM
5050-0344 Rev H PRC2000_SM

... The information contained in this manual will assist the technician in performing preventive maintenance and repair of the PACE PRC 2000 Systems. For details on operation of the system, refer to the System Operation & Maintenance Manual (PACE part number 5050-0313). If you encounter any difficulty o ...
Instructions - Det
Instructions - Det

... equipment installation meets or exceeds the latest revisions of the appropriate NFPA Standards, National Electrical Code (NEC), and all local ordinances. If in doubt, consult the Authority Having Jurisdiction (AHJ) before wiring the system. ...
Signal Integrity Analysis of Package and PCB for High Speed Data
Signal Integrity Analysis of Package and PCB for High Speed Data

... With ever shrinking geometry size, we have reached a point in time in which we cannot draw a direct correlation of the performance of the IC design with respect to the number of transistors on a single chip. As in limited silicon area available factors like tighter packaging space, circuit boards an ...
Service tips - ElektroTanya
Service tips - ElektroTanya

... Standby LED flashes red/green every second. Appliance pulses three times. Line transformer starts up then cuts out. Pulses on line BU correct. 1: Pin 19 of IV01 at 0V. Protection circuit is defective. Check if transistor TP66 (BC858) O/C or if TP69 (BC848) leaky. Standby LED lights up red then goes ...
Effects of Measurements and Pseudo
Effects of Measurements and Pseudo

... distribution systems, considering correlation. In [12], the correlation between loads has been considered in a probabilistic power flow, that uses the real measurements as constraints. In [13], the correlation among different measurements provided by a specific power meter device is used and it is s ...
1N5400, 1N5401, 1N5402, 1N5403, 1N5404, 1N5405
1N5400, 1N5401, 1N5402, 1N5403, 1N5404, 1N5405

... Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use ...
A method for magnetizing curve identification in rotor flux oriented
A method for magnetizing curve identification in rotor flux oriented

UK Power Distribution Limited Use of System Charging
UK Power Distribution Limited Use of System Charging

... 2.24 Measurement Class C, E or CVA charges apply to Exit/Entry Points where HH metering, or an equivalent meter, is used for Settlement purposes. 2.25 Measurement Class D charges apply to Exit Points deemed to be suitable as Unmetered Supplies as permitted in the Electricity (Unmetered Supply) Regul ...
NVT2001, NVT2002 - NXP Semiconductors
NVT2001, NVT2002 - NXP Semiconductors

... 1.0 V and 5 V without the need for a direction pin in open-drain or push-pull applications. Bit widths ranging from 1-bit or 2-bit are offered for level translation application with transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or ...
Bridging the Efficiency Gap in PoE Powered
Bridging the Efficiency Gap in PoE Powered

... TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by ...
Signal Level Control (AGC)
Signal Level Control (AGC)

E50H_E60H
E50H_E60H

... requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 300 to 8000 Hz. The s ...
Principles of Electronic Communication Systems
Principles of Electronic Communication Systems

Specifier Reports Dimming Electronic Ballasts
Specifier Reports Dimming Electronic Ballasts

... device distorts the voltage or current waveform and/or changes the phase relationship between them. A device with ideal power quality characteristics neither distorts the supply voltage nor affects the voltagecurrent phase relationship. NLPIP evaluated power quality for dimming electronic ballasts b ...
PROTECTIVE RELAYING FOR TRANSMISSION AND
PROTECTIVE RELAYING FOR TRANSMISSION AND

... They are preferably where system fault current various widely (due to change in source impedance). There being relatively small change in time with variation fault current, the grading of several relays in series is easier & surer. These relays are also preferred on locations where high transient pe ...
Mounting Instruction
Mounting Instruction

... In the sense of DIN EN 50178 (formerly VDE 0160), the FDS and MDS model series of POSIDRIVE® are electrical components of power electronics for the regulation of energy flow in high-voltage systems. They are exclusively designed to power servo (MDS) and asynchronous (FDS, MDS) machines. Utilization, ...
Power and Performance Methodology
Power and Performance Methodology

Transistors and Logic Gates - Computer Sciences User Pages
Transistors and Logic Gates - Computer Sciences User Pages

... • output depends on stored information (state) plus input so a given input might produce different outputs, depending on the stored information • example: ticket counter advances when you push the button output depends on previous state • useful for building “memory” elements and “state machines” ...
< 1 ... 164 165 166 167 168 169 170 171 172 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report