• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Experiment 4 Comparators, positive feedback, and relaxation
Experiment 4 Comparators, positive feedback, and relaxation

R C
R C

... BOPAMP = _______________ (Exp) _______________ (Theory) d) Determine the Q factor of the circuit. QOPAMP = _______________ (Exp) _______________ (Theory) e) Based on the values of fo, B, and Q that you measured in Parts 6, 7 and 8, discuss the advantages of using an Op Amp with a parallel resonant c ...
Sink/Source DDR Termination Regulator
Sink/Source DDR Termination Regulator

Presentation_pocpa_safety_related-5 - Indico
Presentation_pocpa_safety_related-5 - Indico

... damping mechanism to be fully safe. This means that each energy storage component needs to be carefully designed. Complex environment with multiple energy sources pushes to be cautious. • Most of the converters are water cooled. The main advantage is the electrical efficiency but: electricity and wa ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... electronics, ubiquitous computing devices [2] is increasing rapidly means that power efficient computation has become more important in widely deployed technologies rather than being confined to niche and specialist areas. The popularity of complementary MOS technology can be mainly attributed to in ...
section 26 23 00 - low voltage switchgear
section 26 23 00 - low voltage switchgear

... B. Under 601 Amps: Switches under 601 amps shall be molded case circuit breakers or fused switches with either UL Class L, RK-1, or J fuses, where the interrupting capacity of the device is greater than that of the transformer feed. 2.3 FEEDER CIRCUIT BREAKER DEVICES A. Type: Feeder circuit breakers ...
Completeness
Completeness

... Pulldown network (nMOS) •Output is connected to VSS when a+b=1. VSS ...
Electrical Quantities and Ohm`s Law
Electrical Quantities and Ohm`s Law

... be transmitted through a row of billiard balls, as illustrated in Figure 4-2. The electric current is actually the impulse of electric energy that one electron transmits to another as it changes orbit. The first electron repels the other out of orbit, transmitting its energy to it. The second electr ...
`Millionaire` Electricity and Electromagnetism revision PowerPoint
`Millionaire` Electricity and Electromagnetism revision PowerPoint

... B 3 different speeds of rotation are sequenced C 6 stator coils and 6 rotor coils are set at 60o in the ...
LS7538-LS7539
LS7538-LS7539

... The recommended value of this resistor for 50Hz and 60Hz operation is specified in the ELECTRICAL CHARACTERISTICS. The resistor value determines the Brightness Levels produced. (See Table 2) SYNC Input (Pin 2) 50Hz or 60Hz AC input for zero crossing detection. ...
LT1509 Power Factor and PWM Controller BLOCK DIAGRAM W
LT1509 Power Factor and PWM Controller BLOCK DIAGRAM W

By directly slotting-in to the PLC, measurement of a variety of energy
By directly slotting-in to the PLC, measurement of a variety of energy

... Y-0706 1011 (MDOC) ...
MAX887 100% Duty Cycle, Low-Noise, Step-Down, PWM DC-DC Converter _______________General Description
MAX887 100% Duty Cycle, Low-Noise, Step-Down, PWM DC-DC Converter _______________General Description

... the inductor current is low, smoothing the voltage across the load. During normal operation, the MAX887 regulates output voltage by switching at a constant frequency and then modulating the power transferred to the load per pulse using the PWM comparator. A multi-input comparator sums three weighted ...
New Linear Regulators Solve Old Problems
New Linear Regulators Solve Old Problems

... regulation, and none of that gain is needed to amplify up the reference to a higher output voltage. Industrial applications require large safe operating area. Safe operating area is the ability to carry large currents at high input-output differentials. The safe operating area for several regulators ...
True Energy Instantaneous Energy Values for the Weld
True Energy Instantaneous Energy Values for the Weld

... from that obtained from traditional methods, it does not imply that either of these values are incorrect; just different. If welding parameters have been developed around a Heat Input using the traditional methods, and the actual welds have passed the necessary mechanical tests, it simply means that ...
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E)  LAB1
SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS® (PSS/E) LAB1

Implementation of Control Center Based Voltage and Var
Implementation of Control Center Based Voltage and Var

MAX1812 Dual USB Switch with Fault Blanking General Description Features
MAX1812 Dual USB Switch with Fault Blanking General Description Features

... Fault blanking allows the MAX1812 to handle USB loads that may not be fully compliant with the USB specifications. USB loads with additional bypass capacitance and/or large startup currents can be successfully powered even while protecting the upstream power source. If the switch is able to bring up ...
2SC4793
2SC4793

Megger® Hand-Held TDR / Cable Length Meter Megger® Hand
Megger® Hand-Held TDR / Cable Length Meter Megger® Hand

... Graphic LCD, adjustable back-lighting Safety/EMC/Vibration: IEC-1010-1, CE and ASTM D999.75 Operating Temperature: -20º C to 55°C (-5°F to 130°F), < 90% RH non-condensing Power: Six standard AA alkaline batteries Battery Life: 12 hours of field operation Dimensions: 9.5"H x 4.5"W x 1.9"D (240x115x50 ...
74LCX16646 Low Voltage 16-Bit Transceiver/Register with 5V Tolerant Inputs and Outputs 7
74LCX16646 Low Voltage 16-Bit Transceiver/Register with 5V Tolerant Inputs and Outputs 7

... registered bus transceivers with 3-STATE outputs, providing multiplexed transmission of data directly from the input bus or from the internal storage registers. Each byte has separate control inputs which can be shorted together for full 16-bit operation.The DIR inputs determine the direction of dat ...
Electromagnetic Simulation for Power Integrity: From Analysis to
Electromagnetic Simulation for Power Integrity: From Analysis to

... Since typical PDN impedance is very small, the probe inductance has to be removed (or deembedded) from measurements Assume we want to measure the input impedance of a PDN Using a VNA we get the S-parameters of the setup in the figure below including the probe inductance We always use two probes. For ...
A New Mitigation Strategy for
A New Mitigation Strategy for

... thick to vaporize and the failure could not be reversed. Metallized electrodes do not fail as a permanent short. At the failure point there ...
Installation instructions
Installation instructions

... per terminal, AWG12 (3 mm ) or less. Wiring is to comply with class 1 requirements in North America. Tighten terminal screws to 1.35Nm (1 ft/Lb) only. Ensure all connection wires are rated and approved to the highest voltage connected to the transducer. Note that minimum wire current ratings for CT ...
ÜÇÜNCÜ KUŞAK AKIM TAŞIYICILAR VE UYGULAMALARI
ÜÇÜNCÜ KUŞAK AKIM TAŞIYICILAR VE UYGULAMALARI

... and CL this zero and pole can appear inside the system bandwidth causing a “kind of step” behavior Besides this middle frequency, the upper cutoff frequency remains unchanged ...
< 1 ... 1511 1512 1513 1514 1515 1516 1517 1518 1519 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026