Document
... First, we defined the condition of resonance in a driven series LCR circuit to occur at the frequency w0 that produces the largest value for the peak current in the circuit. At this frequency, which is also the natural oscillation frequency of the corresponding LC circuit, the inductive reactance is ...
... First, we defined the condition of resonance in a driven series LCR circuit to occur at the frequency w0 that produces the largest value for the peak current in the circuit. At this frequency, which is also the natural oscillation frequency of the corresponding LC circuit, the inductive reactance is ...
Electrical Components and Circuits ver2
... region drift away from the junction to form the depletion layer, which contains few charges. Only the small concentration of minority carriers present in each region drifts toward the junction and creates a current. ...
... region drift away from the junction to form the depletion layer, which contains few charges. Only the small concentration of minority carriers present in each region drifts toward the junction and creates a current. ...
AND8255/DA Simple DC SPICE Model for the LLC
... capacitor has been kept in place, but does not play any role in DC. The right side OPAMP just helps to close the loop in DC and have the right operating point automatically setup, e.g. 24 V at a given output power level. In this example, the system delivers 100 W and operates at a switching frequenc ...
... capacitor has been kept in place, but does not play any role in DC. The right side OPAMP just helps to close the loop in DC and have the right operating point automatically setup, e.g. 24 V at a given output power level. In this example, the system delivers 100 W and operates at a switching frequenc ...
FEATURES APPLICATIONS DESCRIPTION
... components: current sense resistor, RCS, the output inductor and the output capacitor(s) to ground. If the voltage on the CS1, and CS2 pins exceed 0.2 V (resistance greater than 40 kΩ), a fault is declared and the device does not start. This is a fault detection feature that insures the output induc ...
... components: current sense resistor, RCS, the output inductor and the output capacitor(s) to ground. If the voltage on the CS1, and CS2 pins exceed 0.2 V (resistance greater than 40 kΩ), a fault is declared and the device does not start. This is a fault detection feature that insures the output induc ...
Binary Input N 263 5WG1 263-1AB01 6 x 230 V AC Binary Input N
... device with 6 volt-free message inputs for 230 V AC (N 263) respectively 24 V AC/DC (N 265). It is used for calling up auxiliary contacts, door- and window contacts etc. The required calling voltage has to be made available by an additional voltage supply. Each of the inputs can be assigned various ...
... device with 6 volt-free message inputs for 230 V AC (N 263) respectively 24 V AC/DC (N 265). It is used for calling up auxiliary contacts, door- and window contacts etc. The required calling voltage has to be made available by an additional voltage supply. Each of the inputs can be assigned various ...
26 22 13 15 lv transformers tp-1s
... losses than NEMA TP-1 or CSA C802.2 & Energy Star efficiencies under Linear load and NEMA TP1, EnergyStar or CSA C802.2 under non-linear loading (K-factor 13 load profile). The transformers shall be designed, constructed and ‘K-rated’ in accordance with UL, CSA and NEMA standards as per their temper ...
... losses than NEMA TP-1 or CSA C802.2 & Energy Star efficiencies under Linear load and NEMA TP1, EnergyStar or CSA C802.2 under non-linear loading (K-factor 13 load profile). The transformers shall be designed, constructed and ‘K-rated’ in accordance with UL, CSA and NEMA standards as per their temper ...
AP7333
... Mobile Communications (GSM) have a transmit/receive duty factor of only 12.5 percent, enabling power savings by putting much of the baseband circuitry into standby mode in between transmit cycles. In baseband circuits, the load often transitions virtually instantaneously from 100µA to 100mA. To meet ...
... Mobile Communications (GSM) have a transmit/receive duty factor of only 12.5 percent, enabling power savings by putting much of the baseband circuitry into standby mode in between transmit cycles. In baseband circuits, the load often transitions virtually instantaneously from 100µA to 100mA. To meet ...
Speed of Sound Experiment
... • Circuitry chamber will be closed to the environment and will hold the power supply, test circuit, and BalloonSat. ...
... • Circuitry chamber will be closed to the environment and will hold the power supply, test circuit, and BalloonSat. ...
Aalborg Universitet Hybrid power filter with reduced inverter power rating
... In a case of improving the harmonic mitigation performance of a classical passive power filter or pure active solution, a separate connection to the grid of both filters (as shown in Fig. 2) is beneficial. As both filters are connected to the grid independently, such topology does not require any ch ...
... In a case of improving the harmonic mitigation performance of a classical passive power filter or pure active solution, a separate connection to the grid of both filters (as shown in Fig. 2) is beneficial. As both filters are connected to the grid independently, such topology does not require any ch ...
26 22 13 15 lv transformers tp-1s
... losses than NEMA TP-1 or CSA C802.2 & Energy Star efficiencies under Linear load and NEMA TP1, EnergyStar or CSA C802.2 under non-linear loading (K-factor 13 load profile). The transformers shall be designed, constructed and ‘K-rated’ in accordance with UL, CSA and NEMA standards as per their temper ...
... losses than NEMA TP-1 or CSA C802.2 & Energy Star efficiencies under Linear load and NEMA TP1, EnergyStar or CSA C802.2 under non-linear loading (K-factor 13 load profile). The transformers shall be designed, constructed and ‘K-rated’ in accordance with UL, CSA and NEMA standards as per their temper ...
LM614 数据资料 dataSheet 下载
... optimize capacitive drive capability: 1. Output Swing: Unloaded, the 42µA pull-down will bring the output within 300 mV of V− over the military temperature range. If more than 42µA is required, a resistor from output to V− will help. Swing across any load may be improved slightly if the load can be ...
... optimize capacitive drive capability: 1. Output Swing: Unloaded, the 42µA pull-down will bring the output within 300 mV of V− over the military temperature range. If more than 42µA is required, a resistor from output to V− will help. Swing across any load may be improved slightly if the load can be ...
01329013 - Department of Electronics
... electronic applications, both digital and analog, use differential circuit techniques, but unfortunately almost all high performance test instruments, including sampling oscilloscope and signal generators, are single-ended, ground-referenced, 50 Ohm instruments. In order to avoid external differenti ...
... electronic applications, both digital and analog, use differential circuit techniques, but unfortunately almost all high performance test instruments, including sampling oscilloscope and signal generators, are single-ended, ground-referenced, 50 Ohm instruments. In order to avoid external differenti ...
erii5 555 timer monostable operation
... comparator 1 is LOW. When the switch S1 is closed driving the TRIGGER input to LOW (more precisely, when it drops below 1/3 VCC), the output of lower inverting comparator 2 is driven HIGH (See Figure 7). From the SR flip-flop truth table below (Table 1), when the S input is HIGH and R is LOW, the ou ...
... comparator 1 is LOW. When the switch S1 is closed driving the TRIGGER input to LOW (more precisely, when it drops below 1/3 VCC), the output of lower inverting comparator 2 is driven HIGH (See Figure 7). From the SR flip-flop truth table below (Table 1), when the S input is HIGH and R is LOW, the ou ...
BDTIC I S O F A C E
... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effective ...
... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effective ...
Electrical Force - University High School
... Negative electrode (black) called cathode. Voltages add when cells are connected ...
... Negative electrode (black) called cathode. Voltages add when cells are connected ...
1.8V to 28V Input, PWM Step-Up Controllers in µMAX General Description Features
... range of battery and AC-powered inputs. An advanced BiCMOS design features low operating current (220µA), adjustable operating frequency (100kHz to 500kHz), soft-start, and a SYNC input allowing the MAX668/ MAX669 oscillator to be locked to an external clock. DC-DC conversion efficiency is optimized ...
... range of battery and AC-powered inputs. An advanced BiCMOS design features low operating current (220µA), adjustable operating frequency (100kHz to 500kHz), soft-start, and a SYNC input allowing the MAX668/ MAX669 oscillator to be locked to an external clock. DC-DC conversion efficiency is optimized ...
Quadruple Line Receiver (Rev. B)
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
Measured Output Voltages of Piezoelectric Devices Depend on the
... strain limitation (<1%).[12] To overcome this limitation, devices built with PZT, including other brittle piezoelectric materials, were typically integrated with stretchable substrates, as demonstrated by several research groups.[13–16] For instance, the integration of piezoelectric PZT ribbons onto ...
... strain limitation (<1%).[12] To overcome this limitation, devices built with PZT, including other brittle piezoelectric materials, were typically integrated with stretchable substrates, as demonstrated by several research groups.[13–16] For instance, the integration of piezoelectric PZT ribbons onto ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.