• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DLP9000FLS 0.9 WQXGA Type A DMD (Rev. B)
DLP9000FLS 0.9 WQXGA Type A DMD (Rev. B)

... micromirror devices (DMDs) are spatial light modulators (SLMs) that modulate the amplitude, direction, and/or phase of incoming light. This advanced light control technology has numerous applications in the industrial, medical, and consumer markets. The streaming nature of the DLP9000XFLS and its DL ...
Atmel AVR1300: Using the Atmel AVR XMEGA ADC
Atmel AVR1300: Using the Atmel AVR XMEGA ADC

... The gain stage does not load the input; hence external signal sources will see very high input impedance for channels that use the gain stage. This is useful for measuring weak signal sources. More details can be found in the datasheet for the specific device. The voltage on any of the two inputs ca ...
Journal of Power Sources Charge regimes for valve
Journal of Power Sources Charge regimes for valve

WebRelay Users Manual
WebRelay Users Manual

NX3DV3899 1. General description Dual double-pole double-throw analog switch
NX3DV3899 1. General description Dual double-pole double-throw analog switch

... The NX3DV3899 is a dual double-pole double-throw analog data-switch suitable for use as an analog or digital multiplexer/demultiplexer. It consists of four switches, each with two independent input/outputs (nY0 and nY1) and a common input/output (nZ). The two digital inputs (1S and 2S) are used to s ...
A Simplified Introduction to Circuit Simulation using SPICE OPUS
A Simplified Introduction to Circuit Simulation using SPICE OPUS

... • A.C. Analysis (Frequency Domain Analysis) — Determination of steady-state response of the circuit when sinusoidal excitation is applied mine the frequency response of the circuit. The frequency of excitation can be varied to determine the frequency response of the circuit. This requires ac command ...
FBI Owner`s Reference
FBI Owner`s Reference

... wide bandwidth design with low negative feedback for sonic accuracy throughout the frequency spectrum. All circuits, including the amplifier output stage, operate in pure Class A mode. The Fully Balanced Integrated Amplifier is a large-format integrated, and as such offers all the power and control ...
BM-EL84 Operation Manual 18.08.14
BM-EL84 Operation Manual 18.08.14

... The TAD BiasMaster unit consists of a high quality calibrated digital measuring instrument with illuminated 3-½ digit display (18 x 61mm), four selectable inputs, vintage pointer knob and two (BM2-EL84) or four (BM4-EL84) probes for noval sockets. With these sockets you are able to measure the quies ...
True Start Performance Starter Installation Instructions (1/06) (page1
True Start Performance Starter Installation Instructions (1/06) (page1

... If you are replacing an existing starter which has failed, pay careful attention to the mode of failure, and look for any mechanical/ electrical problems somewhere else in your assembly which could be corrected to avoid the problem happening again. Common problems are mechanical misalignments, start ...
RMS6061ED58E8W-1333
RMS6061ED58E8W-1333

... 1. Operating temperature is the case surface temperature on the center/top side of the DRAM. 2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0 to 85℃ under all operating ...
HALO - Polar
HALO - Polar

... 0-10VDC low voltage dimming is offered for the 1200 Series LED. This is a common type of dimming for many commercial applications, and the 1200 Series LED modules are rated for and may also be used in residential applications. Note that 1200 Series LED modules are designed and UL listed for NON-IC h ...
ABB wind turbine converters Increased turbine output
ABB wind turbine converters Increased turbine output

... onshore and offshore installations. ABB offers the complete range of converters for wind turbines – from small wind turbines for residential or small business use to utility-scale wind turbines installed in onshore or offshore wind farms. ABB wind turbine converters help increase turbines’ energy pr ...
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Multi-Module
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Multi-Module

BD9853AFV - uri=media.digikey
BD9853AFV - uri=media.digikey

... ・Power dissipation for the selected diode must be within the rated level. Synchronous diode power dissipation (Pdi) is expressed in the following formula: Pdi=Iout(MAX)×tdt×fosc×Vf Iout(MAX) : maximum load current, tdt: dead time 60ns typ,fosc : oscillation frequency, Vf:forward voltage Selecting th ...
DX-40 DX-45 Lynx Panel Meter 4 DIGIT 0.8” LED
DX-40 DX-45 Lynx Panel Meter 4 DIGIT 0.8” LED

MC5 Smart Relay Adapter  Technical Reference Guide www.soc-robotics.com
MC5 Smart Relay Adapter Technical Reference Guide www.soc-robotics.com

Installation, Maintenance And Troubleshooting
Installation, Maintenance And Troubleshooting

... This unit is equipped with a motorized dome motor. To operate, the “Air” switch must be turned to either intake or exhaust, then simply select “open” or “close”, using the “Dome” switch, to raise or lower the dome. NOTE! During dome operation the fan motor will not operate. At the end of open/close ...
F re esca le S em ic onduc to r, I nc
F re esca le S em ic onduc to r, I nc



... Fig. 12, it is obvious that, with the proposed circuit, the CM reduction performance of active EMI lters is improved at frequency range: 150 kHz-4 MHz, where the maximum reduction is about 20 dBuV comparing to the conventional circuit, and about 30 dBuV comparing to without any lter inserted. Agai ...
capacitors - DigitalCommons@University of Nebraska
capacitors - DigitalCommons@University of Nebraska

... Two oppositely charged (±Q) parallel plates have an area A and are separated by a distance d in vacuum. The electric field between the plates is perpendicular to the surface and has a magnitude E = OjEoA. (a) Write the defining equation for capacitance. (b) Determine the potential difference between ...
ICS Regent®
ICS Regent®

... the face of the module will turn on and off repeatedly until the open circuit field wiring is corrected. During this time the module FAULT status LED will also be on and the system will report a fault for this module. ...
Switches - WordPress.com
Switches - WordPress.com

CA‐NLH‐037  NLH 2016 Capital Budget Application  Page 1 of 1 Volume III, Tab 19 – Replace Protective Relays 
CA‐NLH‐037  NLH 2016 Capital Budget Application  Page 1 of 1 Volume III, Tab 19 – Replace Protective Relays 

Coil on Plug: The Wired Differences
Coil on Plug: The Wired Differences

... 1. Remove only low reference: runs fine 2. Remove only chassis ground: runs fine 3. Remove both chassis ground and low reference: runs fine Indicating ability to ground coil electronics through eyelet bolt ground if necessary ...
7 Hints for Precise Current Measurements with the CX3300 Series
7 Hints for Precise Current Measurements with the CX3300 Series

... Hint #1. How to Choose the Right Current Sensor Step 1: Check the measurement current range and required bandwidth In order to characterize the dynamic current, the most important thing is understanding the current range and required bandwidth for the measurement. Three types of current sensor are a ...
< 1 ... 131 132 133 134 135 136 137 138 139 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report