Energy Plus Heater
... ,QVHUWZDOOFDQLQWRRSHQLQJNHHSLQJZDOOFDQÀXVKZLWKZDOOVXUface. Secure can to wall stud with 2 screws (not included) through holes provided in can. IMPORTANT: wall can should be mounted ÀXVKZLWKRXVLGHRIVKHHWURFN Proceed to Part Two. ...
... ,QVHUWZDOOFDQLQWRRSHQLQJNHHSLQJZDOOFDQÀXVKZLWKZDOOVXUface. Secure can to wall stud with 2 screws (not included) through holes provided in can. IMPORTANT: wall can should be mounted ÀXVKZLWKRXVLGHRIVKHHWURFN Proceed to Part Two. ...
Line Reactors - Advanced Industry Support, Inc.
... continuously to compensate for capacitor tolerance and aging. It must also be rated to handle fifth harmonic current of a magnitude equal to 15% of the capacitor fundamental current rating. The nameplate must indicate the rated fundamental and harmonic currents and frequencies. Reactors must be copp ...
... continuously to compensate for capacitor tolerance and aging. It must also be rated to handle fifth harmonic current of a magnitude equal to 15% of the capacitor fundamental current rating. The nameplate must indicate the rated fundamental and harmonic currents and frequencies. Reactors must be copp ...
chapter 6: converters
... The advantages to digital potentiometers are many. Even the lowest resolution digital potentiometers have better setability than their mechanical counterparts. Also, they are immune to mechanical vibration and oxidation of the wiper contact. Obviously, adjustments can be made without human intervent ...
... The advantages to digital potentiometers are many. Even the lowest resolution digital potentiometers have better setability than their mechanical counterparts. Also, they are immune to mechanical vibration and oxidation of the wiper contact. Obviously, adjustments can be made without human intervent ...
Reducing Electromagnetic Interference in DC
... Electromagnetic Interference (EMI) resulting from high rates of changes of voltage and current, impairing other devices’ performance and harming human being’s health, has become a major concern in designing direct current (DC-DC) converters for a long time due to the increasingly wide applications o ...
... Electromagnetic Interference (EMI) resulting from high rates of changes of voltage and current, impairing other devices’ performance and harming human being’s health, has become a major concern in designing direct current (DC-DC) converters for a long time due to the increasingly wide applications o ...
Title A 60 GHz 25% tuning range frequency generator with implicit
... the buffer stage (10.5 mW) is included in the FoM and FoMT calculations. The PN varies between -98.8 and -100.1 dBc/Hz. The FoM has the worst value of 179 dBc/Hz at the lowest frequencies, and best value of 181.9 dBc/Hz at the highest frequencies. Since the switched capacitors have lower Q-factor in ...
... the buffer stage (10.5 mW) is included in the FoM and FoMT calculations. The PN varies between -98.8 and -100.1 dBc/Hz. The FoM has the worst value of 179 dBc/Hz at the lowest frequencies, and best value of 181.9 dBc/Hz at the highest frequencies. Since the switched capacitors have lower Q-factor in ...
Electricity in Home
... below this times a secondto giving an effective 220V. Instead Live L Fuse or mcb OtherTwo-way types ofswitch domestic load use larg Lighting circuits do not require large currents. Typically, a circuit breaker independent radial circuits which are not or fuse of 6 amps is used. The conductors in lig ...
... below this times a secondto giving an effective 220V. Instead Live L Fuse or mcb OtherTwo-way types ofswitch domestic load use larg Lighting circuits do not require large currents. Typically, a circuit breaker independent radial circuits which are not or fuse of 6 amps is used. The conductors in lig ...
FEATURES GENERAL DESCRIPTION —
... RDAC register values. This function can be used to verify whether the write operation was completed successfully. The scroll bars are updated upon each write transfer. The HARDWARE PINS section selects the level of the external control pins, switches the level of the WP pin, and generates a pulse in ...
... RDAC register values. This function can be used to verify whether the write operation was completed successfully. The scroll bars are updated upon each write transfer. The HARDWARE PINS section selects the level of the external control pins, switches the level of the WP pin, and generates a pulse in ...
差分放大器系列AD8334 数据手册DataSheet 下载
... Low output-referred noise: 48 nV/√Hz typical Active input impedance matching Optimized for 10-bit/12-bit ADCs Selectable output clamping level Single 5 V supply operation AD8332 and AD8334 available in lead frame chip scale package ...
... Low output-referred noise: 48 nV/√Hz typical Active input impedance matching Optimized for 10-bit/12-bit ADCs Selectable output clamping level Single 5 V supply operation AD8332 and AD8334 available in lead frame chip scale package ...
Out-of-Step Protection for Generators
... OUT-OF-STEP PROTECTION FOR GENERATORS J. Berdy Electric Utility Systems Engineering Department General Electric Company Schenectady, New York During any stage of development of a power system, there will be some combination of operating conditions, faults or other disturbances which may cause the ...
... OUT-OF-STEP PROTECTION FOR GENERATORS J. Berdy Electric Utility Systems Engineering Department General Electric Company Schenectady, New York During any stage of development of a power system, there will be some combination of operating conditions, faults or other disturbances which may cause the ...
AN10800 Using the BLF578 in the 88 MHz to 108 MHz... Rev. 01 — 13 October 2009 Application note
... function provided by the transistor is the reason it is used rather than a diode. A portion of the −15 mV/°C is summed into the potentiometer (R1). The amount of temperature compensation is set by resistor R4. The ideal value proved to be 2 kΩ. The values of R9, R13 and R14 are not important for tem ...
... function provided by the transistor is the reason it is used rather than a diode. A portion of the −15 mV/°C is summed into the potentiometer (R1). The amount of temperature compensation is set by resistor R4. The ideal value proved to be 2 kΩ. The values of R9, R13 and R14 are not important for tem ...
MAX31855 Cold-Junction Compensated Thermocouple-to
... complete serial-interface read of the cold-junction compensated thermocouple temperature requires 14 clock cycles. Thirty-two clock cycles are required to read both the thermocouple and reference junction temperatures (Table 2 and Table 3.) The first bit, D31, is the thermocouple temperature sign bi ...
... complete serial-interface read of the cold-junction compensated thermocouple temperature requires 14 clock cycles. Thirty-two clock cycles are required to read both the thermocouple and reference junction temperatures (Table 2 and Table 3.) The first bit, D31, is the thermocouple temperature sign bi ...
Document
... The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Hewlett-Packa ...
... The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Hewlett-Packa ...
Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753
... pulse output frequency (CF), which is proportional to the active power. Various system calibration features, i.e., channel offset correction, phase calibration, and power calibration, ensure high accuracy. The part also detects short duration low or high voltage variations. The positive-only accumul ...
... pulse output frequency (CF), which is proportional to the active power. Various system calibration features, i.e., channel offset correction, phase calibration, and power calibration, ensure high accuracy. The part also detects short duration low or high voltage variations. The positive-only accumul ...
transformer loss compensation for metermen
... Transformer losses can be viewed as the power consumed (used) by the transformer when performing work. The harder the transformer works, the more power consumed by the transformer and the larger the losses. The transformer losses can be looked at as if the transformer was a variable load connected t ...
... Transformer losses can be viewed as the power consumed (used) by the transformer when performing work. The harder the transformer works, the more power consumed by the transformer and the larger the losses. The transformer losses can be looked at as if the transformer was a variable load connected t ...
Some Transistors Stuff, Analog-to-Digital
... • In the totem pole arrangement, one guarantees that one of the two transistors is on and the other is off – giving a low-resistance connection to high or low as the case may be. • If we arrange for a third possibility that both transistors are off, then there is a high resistance between the output ...
... • In the totem pole arrangement, one guarantees that one of the two transistors is on and the other is off – giving a low-resistance connection to high or low as the case may be. • If we arrange for a third possibility that both transistors are off, then there is a high resistance between the output ...
In-System Programming ProASIC PLUS Devices App Note
... What is RCK and Why is it Needed for Internal ISP? The ProASICPLUS device contains an internal programming controller that controls the programming of the flash switches. Voltages used during programming are based on an internal voltage reference, but the controller needs a 1 MHz clock derived from ...
... What is RCK and Why is it Needed for Internal ISP? The ProASICPLUS device contains an internal programming controller that controls the programming of the flash switches. Voltages used during programming are based on an internal voltage reference, but the controller needs a 1 MHz clock derived from ...
- Enercon Engineering, Inc.
... independent of load sense / load demand automatic functions. This load demand feature can be over-ridden at the discretion of the operator. 7. When operating in an isolated mode (not paralleled with utility), the control system shall monitor an overload condition, as detected by a drop in bus freque ...
... independent of load sense / load demand automatic functions. This load demand feature can be over-ridden at the discretion of the operator. 7. When operating in an isolated mode (not paralleled with utility), the control system shall monitor an overload condition, as detected by a drop in bus freque ...
IEEE-PSRC_Report_D8_.. - pes-psrc
... Unlike most power system elements (e.g., transformers, capacitor banks, buses), the zone of protection for a transmission line is somewhat unique in that the limits of the zone generally extend to geographically separate locations. Those elements that are entirely contained at one location, along wi ...
... Unlike most power system elements (e.g., transformers, capacitor banks, buses), the zone of protection for a transmission line is somewhat unique in that the limits of the zone generally extend to geographically separate locations. Those elements that are entirely contained at one location, along wi ...
MAX6950/MAX6951 Serially Interfaced, +2.7V to +5.5V, 5- and 8-Digit LED Display Drivers
... The MAX6950 is a five-digit common-cathode display driver. It drives five digits, with each digit comprising eight LEDs with cathodes connected to a common cathode. The display limit is therefore 40 LEDs or digit segments. The MAX6951 is an eight-digit common-cathode display driver. It drives eight ...
... The MAX6950 is a five-digit common-cathode display driver. It drives five digits, with each digit comprising eight LEDs with cathodes connected to a common cathode. The display limit is therefore 40 LEDs or digit segments. The MAX6951 is an eight-digit common-cathode display driver. It drives eight ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.