User`s Guide 150 Watt Stereo Guitar Amplifier
... Congratulations and thank you for choosing another Crate first in guitar amplification: the Crate CPB150 PowerBlockTM 150 watt stereo guitar amplifier. The PowerBlock packs a lot of power and patching options into an amazingly compact and light weight package: 75 watts per channel @ 4 ohms, or 150 w ...
... Congratulations and thank you for choosing another Crate first in guitar amplification: the Crate CPB150 PowerBlockTM 150 watt stereo guitar amplifier. The PowerBlock packs a lot of power and patching options into an amazingly compact and light weight package: 75 watts per channel @ 4 ohms, or 150 w ...
Quadra (VL-1000 750 Kb)
... PTT Connections These jacks, labeled PTT 1 and PTT 2, accept T/R control signals from your exciter. Grounding the center pin of one of these PTT jacks will cause the amplifier to be placed in the “Transmit” mode. These jacks utilize a positive voltage (+5V DC) at very low current (10 mA maximum), so ...
... PTT Connections These jacks, labeled PTT 1 and PTT 2, accept T/R control signals from your exciter. Grounding the center pin of one of these PTT jacks will cause the amplifier to be placed in the “Transmit” mode. These jacks utilize a positive voltage (+5V DC) at very low current (10 mA maximum), so ...
Chapter 24: Alternating-Current Circuits
... 50. The image shows an inductor (L = 0.22 mH) in series with a 15-Ω resistor. These elements are in parallel with a second 15-Ω resistor. An ac generator powers the circuit with an rms voltage of 65 V. In the limit of high frequency, the inductor behaves like a very large resistor. In such a case ne ...
... 50. The image shows an inductor (L = 0.22 mH) in series with a 15-Ω resistor. These elements are in parallel with a second 15-Ω resistor. An ac generator powers the circuit with an rms voltage of 65 V. In the limit of high frequency, the inductor behaves like a very large resistor. In such a case ne ...
GND GND GND
... SWITCH HOOK: After that, in parallel with the Ringer is the Switch Hook, which has two contacts that are in the open position when the telephone is ON HOOK. The DC current in the loop is 0 ma when the telephone is ON HOOK because of the open circuit. The – 48 V battery at the LO is disconnected from ...
... SWITCH HOOK: After that, in parallel with the Ringer is the Switch Hook, which has two contacts that are in the open position when the telephone is ON HOOK. The DC current in the loop is 0 ma when the telephone is ON HOOK because of the open circuit. The – 48 V battery at the LO is disconnected from ...
ics85401.pdf
... The aforementioned trademark, HiPerClockS™ is a trademark of Integrated Circuit Systems, Inc. or its subsidiaries in the United States and/or other countries. While the information presented herein has been checked for both accuracy and reliability, Integrated Circuit Systems, Incorporated (ICS) ass ...
... The aforementioned trademark, HiPerClockS™ is a trademark of Integrated Circuit Systems, Inc. or its subsidiaries in the United States and/or other countries. While the information presented herein has been checked for both accuracy and reliability, Integrated Circuit Systems, Incorporated (ICS) ass ...
2.4-GHz RF Front End
... The exposed die attach pad must be connected to a solid ground plane as this is the primary ground connection for the chip. Inductance in vias to the pad should be minimized. It is highly recommended to follow the reference layout. Changes will alter the performance. Also see the PCB landpattern inf ...
... The exposed die attach pad must be connected to a solid ground plane as this is the primary ground connection for the chip. Inductance in vias to the pad should be minimized. It is highly recommended to follow the reference layout. Changes will alter the performance. Also see the PCB landpattern inf ...
Document
... coupling a result of the changing magnetic flux lines of one coil cutting through the second coil. Turns ratio The ratio of the turns in the secondary winding to the turns in the primary winding. Reflected The resistance of the secondary circuit resistance reflected into the primary circuit. Impedan ...
... coupling a result of the changing magnetic flux lines of one coil cutting through the second coil. Turns ratio The ratio of the turns in the secondary winding to the turns in the primary winding. Reflected The resistance of the secondary circuit resistance reflected into the primary circuit. Impedan ...
I 2
... Copy the following definitions: • Node – any point where 2 or more circuit elements are connected together • Branch – a circuit element between two nodes • Loop – a collection of branches that form a closed path returning to the same node without going through any other nodes or branches twice Use t ...
... Copy the following definitions: • Node – any point where 2 or more circuit elements are connected together • Branch – a circuit element between two nodes • Loop – a collection of branches that form a closed path returning to the same node without going through any other nodes or branches twice Use t ...
KAV-250
... Powerful, flexible, and endowed with the outstanding sonic performance characteristics that are unique to Krell, the KAV–250a/3 is a superior audiophile solution for home theater and multichannel music reproduction. The KAV–250a/3 can, for example, be used to drive the front channels (left, center, ...
... Powerful, flexible, and endowed with the outstanding sonic performance characteristics that are unique to Krell, the KAV–250a/3 is a superior audiophile solution for home theater and multichannel music reproduction. The KAV–250a/3 can, for example, be used to drive the front channels (left, center, ...
EDIBON
... 14.- Application of the Timer/Counter as a meter of time. 15.- Application of the Timer/Counter as a simple counter. 16.- Application of the Timer/Counter as rev-counter or frequency-meter. 17.- Characteristics of an L.E.D. bargraph display unit. 18.- Characteristic of a Mobile Coil Meter. 19.- Comp ...
... 14.- Application of the Timer/Counter as a meter of time. 15.- Application of the Timer/Counter as a simple counter. 16.- Application of the Timer/Counter as rev-counter or frequency-meter. 17.- Characteristics of an L.E.D. bargraph display unit. 18.- Characteristic of a Mobile Coil Meter. 19.- Comp ...
product pdf
... sleek and modern appearance and due to its small and unobtrusive size, this fixture will become almost invisible on the structure to which it will be installed. The STR9 is a totally sealed, low voltage fixture with an external power supply, so there should be no need to ever access the fixture for ...
... sleek and modern appearance and due to its small and unobtrusive size, this fixture will become almost invisible on the structure to which it will be installed. The STR9 is a totally sealed, low voltage fixture with an external power supply, so there should be no need to ever access the fixture for ...
BDTIC www.BDTIC.com/infineon Power Management & Multimarket
... DIAG (Common diagnostic output) The low active DIAG signal contains the OR-wired information of the separated overtemperature detection units for each channel.The output pin DIAG provides an open drain functionality. A current source is also connected to the pin DIAG. In normal operation the signal ...
... DIAG (Common diagnostic output) The low active DIAG signal contains the OR-wired information of the separated overtemperature detection units for each channel.The output pin DIAG provides an open drain functionality. A current source is also connected to the pin DIAG. In normal operation the signal ...
Systematic Design of Space-Time Trellis Codes for Wireless
... Superheterodyne receiver deals them with different blocks ...
... Superheterodyne receiver deals them with different blocks ...
Transformer Fully Explained By faisal qaswar
... VHF band, cores made from nonconductive magnetic ceramic materials called ferrites are common. Some radiofrequency transformers also have movable cores (sometimes called 'slugs') which allow adjustment of the coupling coefficient (and bandwidth)www.bzupages.com of tuned radio-frequency circuits. ...
... VHF band, cores made from nonconductive magnetic ceramic materials called ferrites are common. Some radiofrequency transformers also have movable cores (sometimes called 'slugs') which allow adjustment of the coupling coefficient (and bandwidth)www.bzupages.com of tuned radio-frequency circuits. ...
2.4-GHz RF Front End
... The exposed die attach pad must be connected to a solid ground plane as this is the primary ground connection for the chip. Inductance in vias to the pad should be minimized. It is highly recommended to follow the reference layout. Changes will alter the performance. Also see the PCB landpattern inf ...
... The exposed die attach pad must be connected to a solid ground plane as this is the primary ground connection for the chip. Inductance in vias to the pad should be minimized. It is highly recommended to follow the reference layout. Changes will alter the performance. Also see the PCB landpattern inf ...
TLC7225 数据资料 dataSheet 下载
... Supply voltage range, VDD: to AGND or DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 17 V to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 24 V Supply voltage range, VSS: to AGND or DG ...
... Supply voltage range, VDD: to AGND or DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 17 V to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 24 V Supply voltage range, VSS: to AGND or DG ...
ADL5391 DC to 2.0 GHz Multiplier Data Sheet (Rev. 0)
... transformations (or differential-to-single-ended transformations) can be done using a balun or active components, such as the AD8313, the AD8132 (both with operation down to dc), or the AD8352 (for higher drive capability). If using the ADL5391 single-ended without ac coupling capacitors, the refere ...
... transformations (or differential-to-single-ended transformations) can be done using a balun or active components, such as the AD8313, the AD8132 (both with operation down to dc), or the AD8352 (for higher drive capability). If using the ADL5391 single-ended without ac coupling capacitors, the refere ...
Electrical Drives 1
... What Do we mean by Electrical Drive System? It is the study of the electric system involving controlling electric motors in both steady state and dynamic operation. It is achieved through taking into account the characteristics of the mechanical loads and the behavior of the power electronic conver ...
... What Do we mean by Electrical Drive System? It is the study of the electric system involving controlling electric motors in both steady state and dynamic operation. It is achieved through taking into account the characteristics of the mechanical loads and the behavior of the power electronic conver ...
ACOK MAX1508/MAX1508Y/MAX1508Z Linear Li+ Battery Charger with Integrated Pass FET, Thermal Regulation, and
... The MAX1508 charger uses voltage, current, and thermal-control loops to charge a single Li+ cell and to protect the battery (Figure 1). When a Li+ battery with a cell voltage below 2.5V is inserted, the MAX1508 charger enters the prequalification stage where it precharges that cell with 10% of the u ...
... The MAX1508 charger uses voltage, current, and thermal-control loops to charge a single Li+ cell and to protect the battery (Figure 1). When a Li+ battery with a cell voltage below 2.5V is inserted, the MAX1508 charger enters the prequalification stage where it precharges that cell with 10% of the u ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.