LM675 Power Operational Amplifier
... effectively act as signals at the input, resulting in high frequency oscillation or excessive distortion. It is advisable to keep the output compensation components and the 0.1 μF supply decoupling capacitors as close as possible to the LM675 to reduce the effects of PCB trace resistance and inducta ...
... effectively act as signals at the input, resulting in high frequency oscillation or excessive distortion. It is advisable to keep the output compensation components and the 0.1 μF supply decoupling capacitors as close as possible to the LM675 to reduce the effects of PCB trace resistance and inducta ...
MICRO-TRAK 300 MANUAL VER 1.4.1
... transmit-only device, and will transmit over other stations. It is not a good practice to send position reports too frequently, since this can jam other stations, and will use Micro-Trak battery power too quickly. 120 second checks-ins are recommended. ...
... transmit-only device, and will transmit over other stations. It is not a good practice to send position reports too frequently, since this can jam other stations, and will use Micro-Trak battery power too quickly. 120 second checks-ins are recommended. ...
TUlC-2
... (over representative CDMA conditions) is roughly 1.3% [7]. Therefore, improving average power efficiency is one of the key objectives for future power amplifiers. B. Dynamic Current Biasing The typical approaches for reducing dc power consumption at lower output powers are reducing either DC bias c ...
... (over representative CDMA conditions) is roughly 1.3% [7]. Therefore, improving average power efficiency is one of the key objectives for future power amplifiers. B. Dynamic Current Biasing The typical approaches for reducing dc power consumption at lower output powers are reducing either DC bias c ...
STM1061
... increments. The detector is designed to ignore fast transients on VCC and has a voltage hysteresis (VHYST). The STM1061 asserts an output signal (OUT) whenever VCC goes below the Voltage Detect Threshold (VTH–). The output signal (OUT) stays asserted until VCC goes above the Voltage Detect Release ( ...
... increments. The detector is designed to ignore fast transients on VCC and has a voltage hysteresis (VHYST). The STM1061 asserts an output signal (OUT) whenever VCC goes below the Voltage Detect Threshold (VTH–). The output signal (OUT) stays asserted until VCC goes above the Voltage Detect Release ( ...
Low Voltage System Configuration
... Distribution boxes located on the magnet will fan out each pair of + and – HV to up to 10 trays. These boxes will supply required isolation, filtering, current limiting and grounding of the HV (see figure on the next page). ...
... Distribution boxes located on the magnet will fan out each pair of + and – HV to up to 10 trays. These boxes will supply required isolation, filtering, current limiting and grounding of the HV (see figure on the next page). ...
Application Notes - NXP Semiconductors
... Life support – These products are not designed for use in life support appliances, devices or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips Semiconductors customers using or selling these products for use in such applications do so at th ...
... Life support – These products are not designed for use in life support appliances, devices or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips Semiconductors customers using or selling these products for use in such applications do so at th ...
MAX44264 Ultra-Low Power Op Amp in a Tiny 6-Bump WLP General Description
... The IC operates from a single +1.8V to +5.5V power supply. Bypass power supplies with a 0.1µF ceramic capacitor placed close to the VDD pin. Ground layout improves performance by decreasing the amount of stray capacitance and noise at the op amp’s inputs and outputs. To decrease stray capacitance, m ...
... The IC operates from a single +1.8V to +5.5V power supply. Bypass power supplies with a 0.1µF ceramic capacitor placed close to the VDD pin. Ground layout improves performance by decreasing the amount of stray capacitance and noise at the op amp’s inputs and outputs. To decrease stray capacitance, m ...
GaN Broadband Power Amplifier
... current is ~5.0 amps typical employing a +50 Vdc supply. This PA operates from a +50 Vdc input voltage. Typical harmonic values can be found on the next page of this data sheet. ...
... current is ~5.0 amps typical employing a +50 Vdc supply. This PA operates from a +50 Vdc input voltage. Typical harmonic values can be found on the next page of this data sheet. ...
ENHANCING FUEL BURNING EFFICIENCY BY REGULATE SPARK
... vehicles and etc. This car will give passengers maximum efficiency when they use it. Also, to improve the fuel efficiency, fuel cell is being used to generate electrical power. A fuel cell is an electrochemical energy conversion device that converts the chemicals hydrogen and oxygen into water, and ...
... vehicles and etc. This car will give passengers maximum efficiency when they use it. Also, to improve the fuel efficiency, fuel cell is being used to generate electrical power. A fuel cell is an electrochemical energy conversion device that converts the chemicals hydrogen and oxygen into water, and ...
Detector Electronics
... and charge-sensitive hybridized preamplifier circuitry are assemblies located behind the detector within the PopTop capsule (Fig. 2). They are outside the vacuum chamber and are at room temperature. The very long time constant of the HV filter ensures that the voltage is applied gradually to the det ...
... and charge-sensitive hybridized preamplifier circuitry are assemblies located behind the detector within the PopTop capsule (Fig. 2). They are outside the vacuum chamber and are at room temperature. The very long time constant of the HV filter ensures that the voltage is applied gradually to the det ...
Slides - Course Website Directory
... Economical and widely used in low load density areas Reclosers are used on overhead lines to minimize loss of load ...
... Economical and widely used in low load density areas Reclosers are used on overhead lines to minimize loss of load ...
STEVAL-ILL017V1
... The VIPer17 device is an offline converter with an 800 V rugged power section, a PWM control, overcurrent protection, overvoltage and overload protection, hysteretic thermal protection, soft-start and safe auto-restart after the removal of a fault condition. The brown-out protection function is embe ...
... The VIPer17 device is an offline converter with an 800 V rugged power section, a PWM control, overcurrent protection, overvoltage and overload protection, hysteretic thermal protection, soft-start and safe auto-restart after the removal of a fault condition. The brown-out protection function is embe ...
Output Isolation Modules
... module outputs can be wired in parallel. Elimination of any common galvanic connection point is one part of a general philosophy of total isolation between MicroLok II units to preclude the possibility that a surge or lightning strike that could affect both units simultaneously. In either embodiment ...
... module outputs can be wired in parallel. Elimination of any common galvanic connection point is one part of a general philosophy of total isolation between MicroLok II units to preclude the possibility that a surge or lightning strike that could affect both units simultaneously. In either embodiment ...
Interharmonics: What They Are, Where They Come From and What
... quite consistent. Changes in current magnitude or phase angle can also create sidebar components of the fundamental frequency and its harmonics at interharmonic frequencies. ...
... quite consistent. Changes in current magnitude or phase angle can also create sidebar components of the fundamental frequency and its harmonics at interharmonic frequencies. ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.