Advel PSUs - Indico
... 220VAC Input Frequency :50Hz, Output Voltage: 24VDC and 15VDC versions (see table), arranged in an N+1 or Dual Redundant configuration with Power Sharing. ...
... 220VAC Input Frequency :50Hz, Output Voltage: 24VDC and 15VDC versions (see table), arranged in an N+1 or Dual Redundant configuration with Power Sharing. ...
Bifurcated Arc Fault Detection and Power Distribution
... payloads are added as is the current method with aircraft service changes. The power available for the vehicle is fixed, but loads will differ. All these power requirements can be met in the same form factor connectors. Power to a wire can also be removed, close to the source, when not required. Eli ...
... payloads are added as is the current method with aircraft service changes. The power available for the vehicle is fixed, but loads will differ. All these power requirements can be met in the same form factor connectors. Power to a wire can also be removed, close to the source, when not required. Eli ...
Lab Manual of Basic Electrical Engineering
... 1. When a transformer is energised what types of losses occur in the magnetic frame of the transformer? 2. What information can be obtained from open circuit test of a transformer? 3. Why in open circuit test HV side is always kept open? 4. What is the power factor of a transformer under no load tes ...
... 1. When a transformer is energised what types of losses occur in the magnetic frame of the transformer? 2. What information can be obtained from open circuit test of a transformer? 3. Why in open circuit test HV side is always kept open? 4. What is the power factor of a transformer under no load tes ...
Extend the I C-bus with advanced repeaters and hubs NXP 2-channel I
... PCA9515 is a two-channel repeater that supports two I2C-bus branches of 400 pF each. The PCA9516 is a five-channel hub that separates the I2C-bus into five 400 pF segments each, for a total I2C/SMBus capacitance of 2000 pF. Channel isolation Each repeater channel has an enable/disable feature that ele ...
... PCA9515 is a two-channel repeater that supports two I2C-bus branches of 400 pF each. The PCA9516 is a five-channel hub that separates the I2C-bus into five 400 pF segments each, for a total I2C/SMBus capacitance of 2000 pF. Channel isolation Each repeater channel has an enable/disable feature that ele ...
MAX3188E/MAX3189E ±15kV ESD-Protected, 1Mbps, 1µA RS-232 Transmitters in SOT23-6 General Description
... The MAX3188E/MAX3189E single RS-232 transmitters in a SOT23-6 package are for space- and cost-constrained applications requiring minimal RS-232 communications. These devices consume only 150µA of supply current from ±4.5V to ±6V supplies. They feature a shutdown input that reduces current consumptio ...
... The MAX3188E/MAX3189E single RS-232 transmitters in a SOT23-6 package are for space- and cost-constrained applications requiring minimal RS-232 communications. These devices consume only 150µA of supply current from ±4.5V to ±6V supplies. They feature a shutdown input that reduces current consumptio ...
LC05111CMT
... b. CS pin voltage will get equal to or lower than discharging over-current release current (Iocr) over the delay time of discharging over-current release (Tocr1) due to CS pin pulled down through Rcsd. Consequently, internal power MOS FET as DCHG_SW will be turned on, and normal mode will be resumed ...
... b. CS pin voltage will get equal to or lower than discharging over-current release current (Iocr) over the delay time of discharging over-current release (Tocr1) due to CS pin pulled down through Rcsd. Consequently, internal power MOS FET as DCHG_SW will be turned on, and normal mode will be resumed ...
LET20030C
... ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark. Table 7. ...
... ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark. Table 7. ...
Rupert Neve Portico 5032
... In former years, before the introduction of solid state amplifiers, transformers were necessary to step up to the very high input impedance of tubes, and to provide a balanced input for the microphone line. An input impedance of 1,000 or 1,200 ohms became established for microphones having a source ...
... In former years, before the introduction of solid state amplifiers, transformers were necessary to step up to the very high input impedance of tubes, and to provide a balanced input for the microphone line. An input impedance of 1,000 or 1,200 ohms became established for microphones having a source ...
SP1486E 数据资料DataSheet下载
... SP1486E is a half duplex differential line transceiver suitable for high speed bidirectional communication on multipoint bus transmission lines. Each device contains one differential driver and one differential receiver. Devices comply with TIA/EIA-485 and TIA/EIA-422 standards and also meet the hig ...
... SP1486E is a half duplex differential line transceiver suitable for high speed bidirectional communication on multipoint bus transmission lines. Each device contains one differential driver and one differential receiver. Devices comply with TIA/EIA-485 and TIA/EIA-422 standards and also meet the hig ...
FFPF60SA60DS STEALTH 8 A, 600 V, STEALTH Dual Series Diode
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
Operating instructions - ACS-Control
... For the two or three-wire connection cable between the isolation amplifier and the Pt100 a standard installation cable or multi-wire cable for measuring intends with a maximum of 25 per wire can be used. Pt100 in 2- or 3-wire-measurement can be connected. At a 2-wire-measurement the terminals 1 an ...
... For the two or three-wire connection cable between the isolation amplifier and the Pt100 a standard installation cable or multi-wire cable for measuring intends with a maximum of 25 per wire can be used. Pt100 in 2- or 3-wire-measurement can be connected. At a 2-wire-measurement the terminals 1 an ...
TA3401 Owner`s Manual Doc.indd
... labeled INPUT SENS located in the GAIN CONTROL section of the control panel. • Setting for aftermarket Source Units: Refer to your aftermarket owner’s manual for line level output specification. If the specification is not available, please follow the instructions listed below. X1 POSITION: 100mV – 1V ...
... labeled INPUT SENS located in the GAIN CONTROL section of the control panel. • Setting for aftermarket Source Units: Refer to your aftermarket owner’s manual for line level output specification. If the specification is not available, please follow the instructions listed below. X1 POSITION: 100mV – 1V ...
ADM207E 数据手册DataSheet 下载
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
DEM240128 FGH/V (Version 2)
... orientation of liquid crystal or the generation of air bubbles (black or white). Air bubbles may also be generated if the module is subjected to a strong shock at a low temperature. ...
... orientation of liquid crystal or the generation of air bubbles (black or white). Air bubbles may also be generated if the module is subjected to a strong shock at a low temperature. ...
Circuit for Square Root of Multiplication
... rooting circuits. (i) Rievuraja and Kamsri realised a technique [4] by use of the op-amp supply current sensing which utilises an inherently quadratic characteristic of the op-amp class –AB output stage. (ii) Rievuraja propsed a square rooter [5] using operational transconductance amplifiers (OTAs) ...
... rooting circuits. (i) Rievuraja and Kamsri realised a technique [4] by use of the op-amp supply current sensing which utilises an inherently quadratic characteristic of the op-amp class –AB output stage. (ii) Rievuraja propsed a square rooter [5] using operational transconductance amplifiers (OTAs) ...
E2V Technologies CX1725A, CX1725AX Air Cooled, Hollow Anode
... The CX1725AX, which must be used in conjunction with E2V Technologies resistor box MA942A, permits a larger variation in internal deuterium pressure than the CX1725A. Resistor box settings and/or reservoir heater voltage can be adjusted within the specified limits to obtain the maximum thyratron gas ...
... The CX1725AX, which must be used in conjunction with E2V Technologies resistor box MA942A, permits a larger variation in internal deuterium pressure than the CX1725A. Resistor box settings and/or reservoir heater voltage can be adjusted within the specified limits to obtain the maximum thyratron gas ...
USER`S GUIDE
... provided with the equipment. If the provided plug does not fit into your outlet consult your service agent. Route the power cord so that it is not likely to be walked on, stretched or pinched by items placed upon or against. Grounding: Do not defeat the grounding and polarization means of the power ...
... provided with the equipment. If the provided plug does not fit into your outlet consult your service agent. Route the power cord so that it is not likely to be walked on, stretched or pinched by items placed upon or against. Grounding: Do not defeat the grounding and polarization means of the power ...
Glossary of Battery Terms
... A venting mechanism designed into a cell which activates under specific conditions of abuse to relieve internal pressure. A landfill designed for disposal of normal household trash but which meets government standards designed to protect the environment. The loss of useful capacity of a battery on s ...
... A venting mechanism designed into a cell which activates under specific conditions of abuse to relieve internal pressure. A landfill designed for disposal of normal household trash but which meets government standards designed to protect the environment. The loss of useful capacity of a battery on s ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.