Evaluates: MAX1407/MAX1408/MAX1409/MAX1414 MAX1407 Evaluation Kit/Evaluation System General Description Features
... The EV kit software evaluates the MAX1407/ MAX1408/MAX1409/MAX1414. 7) Slide the 80C32 module’s power switch to the ON position, and confirm the red POWER LED turns on. 8) Start the MAX1407 program by opening its icon in the Start menu. The program automatically downloads KIT1407.c32 to the module. ...
... The EV kit software evaluates the MAX1407/ MAX1408/MAX1409/MAX1414. 7) Slide the 80C32 module’s power switch to the ON position, and confirm the red POWER LED turns on. 8) Start the MAX1407 program by opening its icon in the Start menu. The program automatically downloads KIT1407.c32 to the module. ...
S04_DynoI_L02 - Mechanical Engineering | University of Utah
... displacement can be read directly on a scale or linear potentiometer. If the displacement is smaller, a Linear Variable Differential Transformer (LVDT), encoder, or other sensitive displacement measuring transducer can be used. If the deformation is very small, strain gages can be applied to the sur ...
... displacement can be read directly on a scale or linear potentiometer. If the displacement is smaller, a Linear Variable Differential Transformer (LVDT), encoder, or other sensitive displacement measuring transducer can be used. If the deformation is very small, strain gages can be applied to the sur ...
Evaluates: MAX16826 MAX16826 Evaluation Kit General Description Features
... The Status group box is located at the right of the main window. The software reads the external FET drain voltage measurements, and the boost output voltage measurement from the ADC output registers of the MAX16826. The software multiplies the measured values by the appropriate scaling factor and t ...
... The Status group box is located at the right of the main window. The software reads the external FET drain voltage measurements, and the boost output voltage measurement from the ADC output registers of the MAX16826. The software multiplies the measured values by the appropriate scaling factor and t ...
SP213E 数据资料DataSheet下载
... transmitters, which accept either TTL or CMOS inputs and output the RS-232 signals with an inverted sense relative to the input logic levels. Should the input of the driver be left open, an internal pullup to VCC forces the input high, thus committing the output to a logic-1 (MARK) state. The slew r ...
... transmitters, which accept either TTL or CMOS inputs and output the RS-232 signals with an inverted sense relative to the input logic levels. Should the input of the driver be left open, an internal pullup to VCC forces the input high, thus committing the output to a logic-1 (MARK) state. The slew r ...
THS1030 数据资料 dataSheet 下载
... NOTES: 2. Integral nonlinearity refers to the deviation of each individual code from a line drawn from zero to full scale. The point used as zero occurs 1/2 LSB before the first code transition. The full-scale point is defined as a level 1/2 LSB beyond the last code transition. The deviation is meas ...
... NOTES: 2. Integral nonlinearity refers to the deviation of each individual code from a line drawn from zero to full scale. The point used as zero occurs 1/2 LSB before the first code transition. The full-scale point is defined as a level 1/2 LSB beyond the last code transition. The deviation is meas ...
Fluke-175, Fluke-177, Fluke-179
... and ventilation problems. They are simple to use and have significant improvements over Fluke’s original 70 Series like true-rms, more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. ...
... and ventilation problems. They are simple to use and have significant improvements over Fluke’s original 70 Series like true-rms, more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. ...
512 X 18 First-In, First-Out
... NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output contro ...
... NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output contro ...
Introduction to Piezoelectric Pressure Sensors
... mode sensors must be used with charge amplifiers, special high input impedance amplifiers which have the ability to measure the very small charges (expressed in pC or 10-12 Coulombs) without modifying them. Two distinctly different types of charge amplifiers for use with charge mode pressure sensors ...
... mode sensors must be used with charge amplifiers, special high input impedance amplifiers which have the ability to measure the very small charges (expressed in pC or 10-12 Coulombs) without modifying them. Two distinctly different types of charge amplifiers for use with charge mode pressure sensors ...
MC10H645 (4) VIEW - Ropla Elektronik Sp. z oo
... the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters ...
... the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... wind turbine capability to assist the power system by supplying ancillary services, i.e. such as voltage control, in order to secure a safe and reliable grid operation. Nowadays, DFIG wind turbines constitute the mainstream configuration for large wind turbines, and therefore their capability to sup ...
... wind turbine capability to assist the power system by supplying ancillary services, i.e. such as voltage control, in order to secure a safe and reliable grid operation. Nowadays, DFIG wind turbines constitute the mainstream configuration for large wind turbines, and therefore their capability to sup ...
VT1418 - CPU Board Resets Sporadically
... to a momentary SPST switch. To reset the CPU, the signal is briefly connected to logic ground. In some electrically noisy installations, sporadic CPU resetting has been traced to voltage transients and noise pulses on the pushbutton reset input signal. Most often, this happens when the pushbutton re ...
... to a momentary SPST switch. To reset the CPU, the signal is briefly connected to logic ground. In some electrically noisy installations, sporadic CPU resetting has been traced to voltage transients and noise pulses on the pushbutton reset input signal. Most often, this happens when the pushbutton re ...
High Voltage Products
... further course of opening, this increased pressure initiates a gas flow through the nozzle (3), extinguishing the arc. In this case, the arc energy is used to interrupt the fault current. This energy needs not be provided by the operating mechanism. Major features: • Self-compression interrupter un ...
... further course of opening, this increased pressure initiates a gas flow through the nozzle (3), extinguishing the arc. In this case, the arc energy is used to interrupt the fault current. This energy needs not be provided by the operating mechanism. Major features: • Self-compression interrupter un ...
SR4A Instruction Manual - Gen
... (1) Parallel operation requires additional components in the regulating system. These are resistor R25, transformer T3 and a current transformer CT1. Two of the components are included in a parallel equipped voltage regulator. These are R25 and T3. Current transformer CT1 is a separate item and must ...
... (1) Parallel operation requires additional components in the regulating system. These are resistor R25, transformer T3 and a current transformer CT1. Two of the components are included in a parallel equipped voltage regulator. These are R25 and T3. Current transformer CT1 is a separate item and must ...
CC2592 2.4-GHz Range Extender
... Driving the CC2592 device too far into saturation might result in spurious emissions and harmonics above regulatory limits. This caution should especially be considered for systems targeting a wide operating temperature range, where a combination of low temperature, low supply voltage, and a transce ...
... Driving the CC2592 device too far into saturation might result in spurious emissions and harmonics above regulatory limits. This caution should especially be considered for systems targeting a wide operating temperature range, where a combination of low temperature, low supply voltage, and a transce ...
basics_of_power_qual.. - IDEAL INDUSTRIES, INC.
... – Today, however we have a small inexpensive tools that can be plug at the device or equipment that is being effected. © 2007 Ideal Industries www.idealindustries.com ...
... – Today, however we have a small inexpensive tools that can be plug at the device or equipment that is being effected. © 2007 Ideal Industries www.idealindustries.com ...
PDF: 1.42MB
... (1) Built-in bootstrap diode (BSD) of DIP Ver.5 PS219B* incorporates current limiting resistor (typ. 100Ω). So there isn't any limitation about bootstrap capacitance like current PS219A* has (22μF or less in the case of one long pulse initial charging). (2) Temperature protection function of DIP Ver ...
... (1) Built-in bootstrap diode (BSD) of DIP Ver.5 PS219B* incorporates current limiting resistor (typ. 100Ω). So there isn't any limitation about bootstrap capacitance like current PS219A* has (22μF or less in the case of one long pulse initial charging). (2) Temperature protection function of DIP Ver ...
VOLTAGE CONTROL IN DISTRIBUTED ELECTRICITY GENERATION BY USING SYNCHRONOUS CONDENSER Mikko Mäkelä
... very low values. The depth and duration of the voltage dips are usually defined by a voltage-time diagram. Figure 3 and Table 3 shows an example of FRT requirements during grid faults. The power-generating system must remain connected during the fault even when the grid voltage falls to 0-30% with d ...
... very low values. The depth and duration of the voltage dips are usually defined by a voltage-time diagram. Figure 3 and Table 3 shows an example of FRT requirements during grid faults. The power-generating system must remain connected during the fault even when the grid voltage falls to 0-30% with d ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.