• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Weston 4 Interim Relay Requirements
Weston 4 Interim Relay Requirements

... assets. In addition to measuring the GICs directly, ATC is also measuring the harmonics associated with GIC related autotransformer saturation. To do this we used the existing capabilities of our electronic relays to measure lower order harmonics and report them over the SCADA system to our system o ...
Chapter 70 - Biopotential Amplifiers
Chapter 70 - Biopotential Amplifiers

Commercial PV Using the Enphase M
Commercial PV Using the Enphase M

... enclosure. Locate the LCF near the communication domain it serves. Using an LCF limits the number of microinverters that can be installed in a communication domain to maintain the 100A continuous output rating. Designing with Enphase Line Communication Filters and the Enphase LCF data sheet provide ...
Paralleling Arc Welding Power Sources
Paralleling Arc Welding Power Sources

Next D 45Amp ESC manual
Next D 45Amp ESC manual

... * 2°, 8° – Setting for most of in-runner motors. * 15°, 22° –Setting for motors with 6 or more poles. * 30° – Setting for motors with more poles. In most cases, automatic timing works well for all types of motors. However for high efficiency we recommend the Low timing setting for 2 pole motors (gen ...
On-LOAd TAP-ChAngErs FOr POwEr TrAnsFOrmErs
On-LOAd TAP-ChAngErs FOr POwEr TrAnsFOrmErs

FCPS-24F/FCPS-24FE Field Charger/Power Supply
FCPS-24F/FCPS-24FE Field Charger/Power Supply

DATA SHEET Tytan II D0-25-1/S
DATA SHEET Tytan II D0-25-1/S

... Fuse switch-disconnectors combine fuse protection of system parts with switching capability under load as well as when in overload. Tytan II series devices are main fuse switch-disconnectors for D01 and D02 fuses. Simultaneous isolation of all phases is ensured by the screwcap-less plug-in technolog ...
Safety Messages Hazardous High Voltage
Safety Messages Hazardous High Voltage

bluesxpr.
bluesxpr.

... Incidentally, the stock Electar 30 PT will produce a B+ of 392vdc through a full wave bridge rectifier; many people recommend running EL84's with a B+ of 338vdc to 356vdc. To bring the voltages down to these levels I wired up five 10v/5watt zener diodes between the negative terminal of the FWB and c ...
200 GTL DX - QTH.COM Ham Radio Classified Ads
200 GTL DX - QTH.COM Ham Radio Classified Ads

... 4. Resistor R619 controls the TX on the ??????Government Frequency?????? range and is not installed from the factory. Install the resistor that you removed from R138 to the R619 pads. (1k) to activate the ?????? ...
Dual-Axis Solar Tracker - Worcester Polytechnic Institute
Dual-Axis Solar Tracker - Worcester Polytechnic Institute

... nearly as efficient as solar panels could be, and consume large amounts of fuel in order to run. The needs of future military installments are to have renewable energy sources that require less maintenance and are more energy efficient as opposed to petroleum. In addition, solar energy will not only ...
CHARGER
CHARGER

... voltage correctly. Lithium batteries should not be over discharged to lower than the minimum voltage, as this leads to a rapid loss of capacity or a total failure. Generally, you do not need to discharge a Lithium battery. • Some rechargeable batteries are said to have a memory effect. If they are p ...
TC input limit alarm
TC input limit alarm

... If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replace ...
MAX5250 Low-Power, Quad, 10-Bit Voltage-Output DAC with Serial Interface __________________General Description
MAX5250 Low-Power, Quad, 10-Bit Voltage-Output DAC with Serial Interface __________________General Description

... guaranteed minimum input impedance. When the two reference inputs are driven from the same source, the effective minimum impedance is 5kΩ. A voltage reference with a load regulation of 6ppm/mA, such as the MAX873, would typically deviate by 0.006LSB (0.015LSB worst case) when driving both MAX5250 re ...
June 4th Summer Quarter Starts
June 4th Summer Quarter Starts

... o Low power accumulators provide for low voltage circuits, e.g. auxiliary circuits, do not have to be isolated by the general circuit breaker – Emergency Stop provided they are completely isolated from the main power accumulators. 8. Power Indicator o When the motorcycle is in powered on state, ther ...
MAX9814 - Part Number Search
MAX9814 - Part Number Search

... that the output voltage has exceeded a preset limit. The microphone amplifier gain is then reduced with a selectable time constant to correct for the excessive outputvoltage amplitude. This process is known as the attack time. When the output signal subsequently lowers in amplitude, the gain is held ...
here
here

... The motor torque is produced by the magnetic interaction between the induction field created by the permanent magnet rotor and the current flow in the stator coil. The circumferential value of the torque depends on the product of the actual values of the two aforementioned factors, that is, assuming ...
Laboratory and Field Test of Movable Conduction-Cooled
Laboratory and Field Test of Movable Conduction-Cooled

Transformer Fully Explained By faisal qaswar
Transformer Fully Explained By faisal qaswar

... If a load is connected to the secondary circuit, electric charge will flow in the secondary winding of the transformer and transfer energy from the primary circuit to the load connected in the secondary circuit ...
Extending the workload of the 3000 series calibrators
Extending the workload of the 3000 series calibrators

TPA3112D1 Evaluation Module
TPA3112D1 Evaluation Module

Measuring Temperature with Thermistors
Measuring Temperature with Thermistors

... Over the temperature range of 10° to 100° C, the manufacturer's specification sheet tells us that the thermistor resistance will vary from 4.5 kΩ at 10° C to 153 Ω at 100° C. Because the SCXI-1122 excitation current source delivers 1 mA, the measured voltage will vary from 4.5 V at 10° C to 153 mV a ...
Chapter 3 Double star permanent magnets
Chapter 3 Double star permanent magnets

... he work deals with multiphase machines, which are electrical machines with a number of phases greater or equal than 3. These machines are nowadays quite common and a brief presentation of general multiphase machines theories are illustrated. Due to development ...
ECE137A Notes Set 1: Bipolar Transistors Characteristics
ECE137A Notes Set 1: Bipolar Transistors Characteristics

... Modes of operation: Cutoff Cut off BE junction reverse biased, or not sufficiently forward biased to turn junction on. BC junction reverse biased If the base - emitter voltage is too small (barely forward biased) then the emitter current will be near zero. The transistor is off. Cutoff is a second ...
< 1 ... 342 343 344 345 346 347 348 349 350 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report