AD5242 数据手册DataSheet下载
... nominal resistance (RAB ) of the VR has 256 contact points accessed by the Wiper Terminal, plus the B Terminal contact. The 8-bit data in the RDAC latch is decoded to select one of the 256 possible settings. Assume a 10 kΩ part is used; the wiper’s first connection starts at the B Terminal for data ...
... nominal resistance (RAB ) of the VR has 256 contact points accessed by the Wiper Terminal, plus the B Terminal contact. The 8-bit data in the RDAC latch is decoded to select one of the 256 possible settings. Assume a 10 kΩ part is used; the wiper’s first connection starts at the B Terminal for data ...
Wind turbine power generation emulation via doubly fed induction
... can control the DFIG rotor speed since traditional Wind Turbine Generators would use turbine blade pitch control in tandem with a synchronous generator to provide a constant speed, and hence a constant output frequency. Further, it is noteworthy that a wind-speed profile can be adapted to a specific ...
... can control the DFIG rotor speed since traditional Wind Turbine Generators would use turbine blade pitch control in tandem with a synchronous generator to provide a constant speed, and hence a constant output frequency. Further, it is noteworthy that a wind-speed profile can be adapted to a specific ...
Liebert PSI 120V User Manual
... CONDITIONS OF USE—The input supply outlet must be within 6 ft. (1.8m) of the UPS and be easily accessed. This UPS provides conditioned power to connected equipment. It is not intended for use with life-support and other designated “critical” devices. Maximum load must not exceed that shown on the U ...
... CONDITIONS OF USE—The input supply outlet must be within 6 ft. (1.8m) of the UPS and be easily accessed. This UPS provides conditioned power to connected equipment. It is not intended for use with life-support and other designated “critical” devices. Maximum load must not exceed that shown on the U ...
NTS0103 1. General description Dual supply translating transceiver; open drain; auto
... (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any voltage between 1.65 V and 3.6 V and VCC(B) can be supplied at any voltage between 2.3 V and 5.5 V, making the device suitable for translating between any of the voltage nodes (1.8 V, 2.5 ...
... (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any voltage between 1.65 V and 3.6 V and VCC(B) can be supplied at any voltage between 2.3 V and 5.5 V, making the device suitable for translating between any of the voltage nodes (1.8 V, 2.5 ...
Unit -5 - WordPress.com
... So magnitude of the resultant flux is once again 1.5∅m but it is further rotated by 60° in clockwise direction from its position for θ=120°. The resultant of the three alternating fluxes, separated from each other by 120°, has constant amplitude of 1.5∅m where ∅m is maximum amplitude of an individua ...
... So magnitude of the resultant flux is once again 1.5∅m but it is further rotated by 60° in clockwise direction from its position for θ=120°. The resultant of the three alternating fluxes, separated from each other by 120°, has constant amplitude of 1.5∅m where ∅m is maximum amplitude of an individua ...
MAX6730–MAX6735 Single-/Dual-/Triple-Voltage µP Supervisory Circuits with Independent Watchdog Output General Description
... The MAX6730–MAX6735 single-/dual-/triple-voltage microprocessor (µP) supervisors feature a watchdog timer and manual reset capability. The MAX6730– MAX6735 offer factory-set reset thresholds for monitoring voltages from +0.9V to +5V and an adjustable reset input for monitoring voltages down to +0.63 ...
... The MAX6730–MAX6735 single-/dual-/triple-voltage microprocessor (µP) supervisors feature a watchdog timer and manual reset capability. The MAX6730– MAX6735 offer factory-set reset thresholds for monitoring voltages from +0.9V to +5V and an adjustable reset input for monitoring voltages down to +0.63 ...
Maintenance_&_Troubleshooting
... Dubious alarm signal from digital input (pCO1, pCOC and pCO3). Check the voltage between the common terminal “IDC1” and the terminal of the digital input indicating the alarm “IDn”, in the following conditions: 1) if there is voltage (24 Vac or 24 Vdc, depending on the power supply used for the di ...
... Dubious alarm signal from digital input (pCO1, pCOC and pCO3). Check the voltage between the common terminal “IDC1” and the terminal of the digital input indicating the alarm “IDn”, in the following conditions: 1) if there is voltage (24 Vac or 24 Vdc, depending on the power supply used for the di ...
LAB-2 (Tutorial) Simulation of LNA (Cadence
... Select Port (Fixed R (Port)) Gain Compression Æ 1dB Extrapolation Point Æ -40dB Ist Order Harmonic Æ 2.4G Activate the Schematic Window and click on Output PORT to view the results as shown in Fig-9. A PSS analysis calculates the operating power gain. That is, the ratio of power delivered ...
... Select Port (Fixed R (Port)) Gain Compression Æ 1dB Extrapolation Point Æ -40dB Ist Order Harmonic Æ 2.4G Activate the Schematic Window and click on Output PORT to view the results as shown in Fig-9. A PSS analysis calculates the operating power gain. That is, the ratio of power delivered ...
AD5304 数据手册DataSheet 下载
... Serial Data Input. This device has a 16-bit shift register. Data is clocked into the register on the falling edge of the serial clock input. The DIN input buffer is powered down after each write cycle. Serial Clock Input. Data is clocked into the input shift register on the falling edge of the seria ...
... Serial Data Input. This device has a 16-bit shift register. Data is clocked into the register on the falling edge of the serial clock input. The DIN input buffer is powered down after each write cycle. Serial Clock Input. Data is clocked into the input shift register on the falling edge of the seria ...
Low Cost TRIAC Control with MSP430 16-Bit
... List of Figures 1 Timer A Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Triac Control Circuit Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... List of Figures 1 Timer A Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Triac Control Circuit Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
specification for vhf transreceiver and 12v power supply
... The VHF Sets shall have following features: 3.1.1 The VHF sets shall work as Master/Slave mode within a group. 3.1.2 The VHF sets shall communicate with other sets on ID basis. 3.1.3 The VHF Sets shall have self check facility. 3.1.4 The VHF Sets shall have Radio Check facility to determine particul ...
... The VHF Sets shall have following features: 3.1.1 The VHF sets shall work as Master/Slave mode within a group. 3.1.2 The VHF sets shall communicate with other sets on ID basis. 3.1.3 The VHF Sets shall have self check facility. 3.1.4 The VHF Sets shall have Radio Check facility to determine particul ...
Tech Note MSP to GE 90 Micro Revision: 4.11 Following are some
... input that is %I1, %I3, %I5, and %I7 for HSCs for channels 1, 2 3 and 4 respectively. The Preload/Strobe inputs are %I2, %I4, %I6, and %I8 for HSCs or channels 1, 2 3 and 4 respectively. If a counter is used for an MSP its corresponding Preload/Strobe input must remain disconnected and can not be us ...
... input that is %I1, %I3, %I5, and %I7 for HSCs for channels 1, 2 3 and 4 respectively. The Preload/Strobe inputs are %I2, %I4, %I6, and %I8 for HSCs or channels 1, 2 3 and 4 respectively. If a counter is used for an MSP its corresponding Preload/Strobe input must remain disconnected and can not be us ...
... When selecting the location where you are going to mount the ISONAS readercontroller, a few guidelines should be observed. 1) The reader-controller should be kept at least 2 feet from another ISONAS reader-controller, and 6 feet from any other RF emitting device. 2) Assure that the window on the bac ...
PROTECTIVE RELAYING FOR TRANSMISSION AND
... Limits of accuracy as set by IS: 3231 is shown in shows application to a sectional radial feeder. It seems mat with assumed relay settings and tolerances as per, the minimum permissible time grading interval for successive locations works out to 0.5 seconds. This implies that with large number of se ...
... Limits of accuracy as set by IS: 3231 is shown in shows application to a sectional radial feeder. It seems mat with assumed relay settings and tolerances as per, the minimum permissible time grading interval for successive locations works out to 0.5 seconds. This implies that with large number of se ...
AD7709 数据手册DataSheet下载
... When the part is placed in power-down mode for a single conversion/second, at an update rate of 19.79 Hz, the current consumption is higher compared to when the part is placed in standby mode as the crystal oscillator takes approximately 100 ms to begin clocking. The device will, therefore, use full ...
... When the part is placed in power-down mode for a single conversion/second, at an update rate of 19.79 Hz, the current consumption is higher compared to when the part is placed in standby mode as the crystal oscillator takes approximately 100 ms to begin clocking. The device will, therefore, use full ...
0160-5.9 - Rockwell Automation
... input signals that will start and stop the motor. A device that routinely disconnects then reapplies line power to the controller for the purpose of starting and stopping the motor should not be used. If it is necessary to use this method for starting and stopping or if frequent cycling of power is ...
... input signals that will start and stop the motor. A device that routinely disconnects then reapplies line power to the controller for the purpose of starting and stopping the motor should not be used. If it is necessary to use this method for starting and stopping or if frequent cycling of power is ...
SubLVDS Camera Sensor Interface Reference Design (XAPP582)
... When probing using an IBIS model with Mentor Graphics, At DIE should be selected instead of At PIN. This gives a better simulation result. The differential output should be used to measure the eye opening. For this simulation, a differential probe was inserted at R4.1 and R3.1. The result was thus d ...
... When probing using an IBIS model with Mentor Graphics, At DIE should be selected instead of At PIN. This gives a better simulation result. The differential output should be used to measure the eye opening. For this simulation, a differential probe was inserted at R4.1 and R3.1. The result was thus d ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.