• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX748A/MAX763A 3.3V, Step-Down, Current-Mode PWM DC-DC Converters __________________General Description
MAX748A/MAX763A 3.3V, Step-Down, Current-Mode PWM DC-DC Converters __________________General Description

... The undervoltage lockout feature monitors the supply voltage at V+ and allows operation to start when V+ rises above 2.95V. When V+ falls, operation continues until the supply voltage falls below 2.7V (typ). When an undervoltage condition is detected, control logic turns off the output power FET and ...
3-Phase Voltage Monitor - Intermountain Electronics, Inc.
3-Phase Voltage Monitor - Intermountain Electronics, Inc.

... This document contains information intended to aid in the proper installation and operation of the product described. Although this information will prove useful to the properly trained and qualified user, it is not practical to cover every possible situation, installation contingency, or other deta ...
CA800011EN
CA800011EN

... 300 A externally operated series multiple (dual voltage) switches General Eaton uses its Cooper Power™ series 300 A externally operated series multiple switch to change connection of de-energized transformer windings between series and parallel to provide different common transformer voltage ratios. ...
Improved Reset / Power Down Alarm Circuit
Improved Reset / Power Down Alarm Circuit

... Here VIN is not near 5 volts, but at some voltage above the regulator drop out voltage1 and below the normal operating voltage. At power down this voltage will decline well before the supply voltage. The result is that the PIC MCLR line will be brought to Vss level while its supply voltage (VDD-VSS) ...
Objective bits
Objective bits

the Booklet
the Booklet

... side of the power company’s distribution transformers. The power company can provide primary voltage service (over 600 volts) to qualified customers directly at the high voltage or “primary” distribution system standard for the location at which service is requested. Primary service is available pro ...
Forward Type Switched Mode Power Supply
Forward Type Switched Mode Power Supply

... for a part of (1-δ) T period. In case of discontinuous inductor current, the output voltage, which is the average of voltage across points ‘P’ and ‘N’ will have a higher magnitude than the one given by Eqn. (23.3). Under discontinuous inductor current the relation between output voltage and switch d ...
Quattro Inverter/Charger
Quattro Inverter/Charger

... capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery. ...
english - KEK Concept GmbH
english - KEK Concept GmbH

TRIODE ELECTRONICS JCM800 2203 100W LAYOUT
TRIODE ELECTRONICS JCM800 2203 100W LAYOUT

... dissipation. (70% = 17.5 watts) Divide your desired wattage by the plate voltage that you wrote down from step 2. (example: 17.5/450 = .038 or 38mV) This is your desired bias voltage (probably between 30 and 40 mV). 4) Set your meter to lowest DC Volts setting (200mV or less) and touch the common (g ...
FOG-901 and FOG-901NP Momentary Switch to
FOG-901 and FOG-901NP Momentary Switch to

... efficiency, reduces voltage drop and reduces cable thicknesses and wiring loom cost. The units also feature three ‘enable’ inputs which control the operation of the module. The FOG-901 or FOG-901NP will be inactive until at least one of these enable inputs is connected to +12V, at which time the uni ...
DC Circuits I - Galileo and Einstein
DC Circuits I - Galileo and Einstein

... The emf E and Internal Resistance • This chemically generated voltage E also has to push the current through the battery itself. • The battery has an internal resistance, usually denoted by r, so for a current I in the circuit, the battery supplies to the outside world a terminal voltage • V= ...
INVISIBLE BROKEN WIRE DETECTOR
INVISIBLE BROKEN WIRE DETECTOR

Value
Value

... These Hall-effect sensors accurately track extremely small changes in magnetic flux density—changes generally too small to operate Hall-effect switches. As motion detectors, gear tooth sensors, and proximity detectors, they are magnetically driven mirrors of mechanical events. As sensitive monitors ...
DN41 - Switching Regulator Allows Alkalines to Replace NiCads
DN41 - Switching Regulator Allows Alkalines to Replace NiCads

... Figure 4 shows efficiency exceeding 85%. The diode and LT1270 switch are the two main loss elements. The Schottky diode introduces a relatively constant 7% loss, while the LT1270 switch loss varies with battery voltage. As battery voltage decreases, switch current and duty cycle increase. This has a ...
simulation results - Indico - Variable Energy Cyclotron Centre
simulation results - Indico - Variable Energy Cyclotron Centre

... and off for equal time. This will ensure equal loading of all modules. In the system, 4 modules are connected in series through freewheeling diode. Each module has a period T of 200µs and duty cycle of 0.8. As control signal of the PSM is based on stage rotation [2], therefore the second IGBT turned ...
Not Recommended for New Designs
Not Recommended for New Designs

... Conservative design dictates that the diode average current rating be 2 times the desired output current. If operation with extended short-circuit or overload time is expected, then the diode current rating must exceed the current limit (6.5A = MAX724, 2.6A = MAX726), and heat sinking may be necessa ...
truecontrol
truecontrol

... T uePower power supply with a special external control panel that gives you the flexibility to adjust the main output voltages and minimum fan settings for peak perf r ormance. So the power supply can provide more cooling or less noise, plus precise output rf voltages for maximum stability. y y. Wit ...
note1448_20mA Analog Input
note1448_20mA Analog Input

... The main disadvantage is the effect of the analog input impedance of 47K ohms. This resistance is not constant or precise. Therefore, this voltage may vary significantly over operating conditions and from one controller to the next. This method will provide a voltage that will vary from 0 to 9.89 V ...
Softstart
Softstart

... TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. ...
3A, 52kHz, Step-Down Switching Regulator LM2576
3A, 52kHz, Step-Down Switching Regulator LM2576

... design of a step-down switching regulator (buck converter). All circuits of this series are capable of driving a 3.0A load with excellent line and load regulation. These devices are available in fixed output voltages of 3.3V, 5.0V, 12V and an adjustable output version. These regulators were designed ...
DN351 - Versatile Micropower Voltage Reference Provides Resistor Programmable Output from 0.4V to 18V
DN351 - Versatile Micropower Voltage Reference Provides Resistor Programmable Output from 0.4V to 18V

... In applications where a reference potential greater than 0.4V is required, the simple addition of a feedback voltage divider programs the buffer op amp to provide gain. Figure 2 shows the typical connections for developing a reference voltage above 0.4V with the added feedback components. This confi ...
Monitoring battery voltage with RCtime
Monitoring battery voltage with RCtime

Annexure – 1 to the Tender Enquiry No.DPS/AMPU/MIC/1704
Annexure – 1 to the Tender Enquiry No.DPS/AMPU/MIC/1704

... Low power, very low ripple DC-DC converter to generate 300V to 1300V high voltage software tunable, bias for photomultiplier load of 5M, Necessary shielding to eliminate noise interference caused by switching and magnetic circuits of DC-DC converter. Power Requirement : 12V DC @ 50mA or less in full ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... Isolation circuit is used between the control circuit and power circuit as devices in control circuit are not capable of handling voltages greater than 24V, whereas the power circuit operates at a voltage of around 110V or more. For this purpose an optocoupler is used. An opto-isolator, also called ...
< 1 ... 1631 1632 1633 1634 1635 1636 1637 1638 1639 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report