• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design Solutions 8 - 2-Step Power Conversion: Portable Power for
Design Solutions 8 - 2-Step Power Conversion: Portable Power for

... inductor current ramp-up and a much slower current ramp-down. The inductance value must be large enough to keep the current under control during the ramp-up. This requires a larger inductance than for operation with a low input voltage. Fast current rise and slow current decay means that the transie ...
Today`s Objectives
Today`s Objectives

... difference per unit current in the source when current passes through the wire. ...
Full Article
Full Article

... describing the positive output elementary super lift luo converter and PI control is designed.In [4] IntrtroducesThe voltage-lift technique using voltage-lift circuit has been successfully applied to several series of DC-DC Luo converters. However, the voltage-lift circuit definitely has an unavoida ...
EE340 Lec Al Midterm Exam — Fall Term 2007
EE340 Lec Al Midterm Exam — Fall Term 2007

Section #26 33 53 - Static Uninterruptible Power Supply
Section #26 33 53 - Static Uninterruptible Power Supply

... For maintenance purposes, system can be bypassed automatically by manual selection at control panel to connect load directly to ac mains. Transfer without load interruption and leaving inverter energized. Load transfer from mains back to system automatically by manual selection at control panel when ...
HI-200, HI-201 Datasheet
HI-200, HI-201 Datasheet

... All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9001 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes ...
Unit – 7
Unit – 7

85-W 48-V Input Dual-Complimentary Output DC/DC Converter for
85-W 48-V Input Dual-Complimentary Output DC/DC Converter for

... continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited in ...
An Application of the Inverting Integrator
An Application of the Inverting Integrator

dc-dc convertor structu dc convertor structu dc convertor
dc-dc convertor structu dc convertor structu dc convertor

... of amplitude equal to 1/n of the corresponding current convertor with one arm  The absorbed current to the inlet is triangular and 1/n2 amplitude and ripple frequency is also n*fc,  The losses through the inductors are reduced because their corresponding current will be 1/n. A disadvantage in achi ...
Compact Device Modelling for System Simulation - Mos-AK
Compact Device Modelling for System Simulation - Mos-AK

... • Inductive switching shown here. • Instantaneous power dissipations • IGBT turn-on (left), IGBT turn-off shown to validate switching (right). energies. ...
Non-RF Applications for the Surface Mount Schottky Diode Pairs
Non-RF Applications for the Surface Mount Schottky Diode Pairs

... states in the metal. This flow of electrons builds a depletion potential across the junction. The difference in energy levels between semiconductor and metal is called a Schottky barrier. P-doped Schottky barrier diodes excel at applications requiring ultra low turn-on voltage (such as zero biased R ...
6.302 Feedback Systems
6.302 Feedback Systems

... We’ve been talking about how feedback is used successfully in countless different applications. We’ve said before, and I repeat here, it is astounding that the same feedback theory that helps stabilize an inverted pendulum helps us control op-amps. Or motors. Or magnetic levitation systems. The list ...
Sollatek aUtomatic StabiliSed protector (aSp)
Sollatek aUtomatic StabiliSed protector (aSp)

uv tron® driving circuit c3704 series
uv tron® driving circuit c3704 series

... This background cancel circuit outputs signal pulses of 10ms width only when 3 to 9 pulses enter the circuit with a time interval of 2 seconds or less from the UV TRON. Cancel level can be set in 4 steps (number of pulses: 3, 5, 7, 9) by this jumper lead. Connect to “3” for general use. When using w ...
A Single-phase-to-three-phase Power Converter with an Active
A Single-phase-to-three-phase Power Converter with an Active

... power converter circuit with power factor correction (PFC) circuit. In order to suppress the harmonic currents, a boost chopper circuit is added to DC link in Figure 1(a). This circuit can obtain sinusoidal waveform of the input current because the boost chopper controls the input current with a cur ...
DV2-3G Metro Power Solutions (UL Listed)
DV2-3G Metro Power Solutions (UL Listed)

... 48Vdc systems up to 600A maximum load current. 24Vdc systems up to 500A maximum load current. Eaton DV2-3G Metro Power Solutions are ideal for low to medium power telecommunications applications requiring compact, efficient and flexible DC power. Typical applications include standby DC power for cus ...
D1U3CS-D-1600-HC4EC Series
D1U3CS-D-1600-HC4EC Series

... 2.84/1.31 lbs/kg ...
Switch_Mode_Inverters
Switch_Mode_Inverters

... Fundamental Frequency Component of VAo (Cont’d) • Let us assume that Vcontrol varies very little during a switching time period, that is, mf is large. • Therefore, assuming Vcontrol to be constant over a switching time period, following figure indicates how the "instantaneous average" value of vAo ...
PPT
PPT

STU13005N
STU13005N

... time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the S ...
Syllabus
Syllabus

High AC input voltage limiting circuit
High AC input voltage limiting circuit

... At high line voltage 440 VAC the efficiency is decreased because of the combined energy losses in both the converter and clamping circuit. At low line voltage of 90 VAC, the efficiency is decreased because of the increased conduction loss in Q2 of the clamping circuit (Figure 7 and Figure 8). ...
V/F Converter ICs Handle Frequency-to-Voltage Needs
V/F Converter ICs Handle Frequency-to-Voltage Needs

TLE4250-2G
TLE4250-2G

< 1 ... 1514 1515 1516 1517 1518 1519 1520 1521 1522 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report