Diris A40
... - Communication with PROFIBUS-DP protocol (up to 1,5 Mbauds); with three wire (+,- and 0V) RS 485 link enabling to be viewed and configured. - 31-days storing of P+, P-, Q+, Q- with a internal / external synchronization signal. This signal can be set to 5, 8, 10, 15, 20, 30 and 60 minutes. Storing o ...
... - Communication with PROFIBUS-DP protocol (up to 1,5 Mbauds); with three wire (+,- and 0V) RS 485 link enabling to be viewed and configured. - 31-days storing of P+, P-, Q+, Q- with a internal / external synchronization signal. This signal can be set to 5, 8, 10, 15, 20, 30 and 60 minutes. Storing o ...
WEG launches new cost-effective variable speed drive with
... air-cooled MVW01 medium voltage variable speed drives - from 6.5 MW to 16 MW for voltages from 2.3 kV to 4.16 kV - to meet the needs of medium voltage three-phase induction and synchronous motors across a broader power range. The overall product line now covers the voltage range from 2.3 kV to 6.9 k ...
... air-cooled MVW01 medium voltage variable speed drives - from 6.5 MW to 16 MW for voltages from 2.3 kV to 4.16 kV - to meet the needs of medium voltage three-phase induction and synchronous motors across a broader power range. The overall product line now covers the voltage range from 2.3 kV to 6.9 k ...
Flash Memory - School of Electrical Engineering and Computer
... The simulation results shows efficiency of the power management algorithm Dynamic Voltage Adjustment algorithm is useful in the implementation of portable devices which saves battery power We gained a good knowledge in various power management algorithms. ...
... The simulation results shows efficiency of the power management algorithm Dynamic Voltage Adjustment algorithm is useful in the implementation of portable devices which saves battery power We gained a good knowledge in various power management algorithms. ...
63-1337-01 - Class 200 Meters Three-Phase Meters
... • Optional removable terminal block for pulse output. • Industrial-grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installations with 1-1/16 in. KO (3/4 in. Cond.) on bottom of enclosure. • Non-volatile Memory. ...
... • Optional removable terminal block for pulse output. • Industrial-grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installations with 1-1/16 in. KO (3/4 in. Cond.) on bottom of enclosure. • Non-volatile Memory. ...
Latest Technology PT IGBTs vs. Power MOSFETs
... and low conduction loss, the IGBT is the device of choice for high current and high voltage applications. Now with the latest generation of PT IGBTs, the tradeoff between switching and conduction losses is balanced so that IGBTs encroach upon the high frequency, high efficiency domain of power MOSFE ...
... and low conduction loss, the IGBT is the device of choice for high current and high voltage applications. Now with the latest generation of PT IGBTs, the tradeoff between switching and conduction losses is balanced so that IGBTs encroach upon the high frequency, high efficiency domain of power MOSFE ...
6501 is a multi-channel DC voltage current source/monitor
... Each SMU has eight measurement functions: VSIM, ISVM, VSVM, ISIM VM (voltmeter), IM (ammeter), VSRM (voltage source resistance measurement) and ISRM (current source resistance measurement) and other effective functions for characteristic evaluation of electronic components such as pulse measurement, ...
... Each SMU has eight measurement functions: VSIM, ISVM, VSVM, ISIM VM (voltmeter), IM (ammeter), VSRM (voltage source resistance measurement) and ISRM (current source resistance measurement) and other effective functions for characteristic evaluation of electronic components such as pulse measurement, ...
Parallel Circuits - Mr. Britton / FHS Physics
... if one light turns off, the others stay on if you turn off one light, all the lights turn off has more than one path for the electrical current to flow the devices have the same current the voltage drop across each device is the same ...
... if one light turns off, the others stay on if you turn off one light, all the lights turn off has more than one path for the electrical current to flow the devices have the same current the voltage drop across each device is the same ...
BS2, A/D conversion, phototransistors, thermistors, ultrasonic range
... So the resulting representation would be b10011110 or d158 / 256 * 5V = 3.086V. You should notice two interesting points about successive approximation. The first is that because it always underestimates the correct analog signal, it is possible to choose the “wrong” approximation. 3.1054 is a much ...
... So the resulting representation would be b10011110 or d158 / 256 * 5V = 3.086V. You should notice two interesting points about successive approximation. The first is that because it always underestimates the correct analog signal, it is possible to choose the “wrong” approximation. 3.1054 is a much ...
Design and development of high voltage high power operational
... stage is biased as class A/B. Third stage is the buffer stage which can provide the proper current gain so that amplifier can provide the maximum voltage swing. The specifications of the designed power opamp are given in table 1. The schematic for the opamp designed is given in figure 2. 3.1 Input o ...
... stage is biased as class A/B. Third stage is the buffer stage which can provide the proper current gain so that amplifier can provide the maximum voltage swing. The specifications of the designed power opamp are given in table 1. The schematic for the opamp designed is given in figure 2. 3.1 Input o ...
DCM2000(6)-6280 / 94087
... DCM2000(6)-6280 P/N 94087 Behlman’s DCM2000 series of COTS power supplies are highly reliable, switch mode units built for high-end industrial or military applications. The DCM2000 accepts type III MIL-STD-1399 115/200 VAC, 3-Phase, 400 Hz input power and complies with the applicable input harmonic ...
... DCM2000(6)-6280 P/N 94087 Behlman’s DCM2000 series of COTS power supplies are highly reliable, switch mode units built for high-end industrial or military applications. The DCM2000 accepts type III MIL-STD-1399 115/200 VAC, 3-Phase, 400 Hz input power and complies with the applicable input harmonic ...
DC25617623
... reactance at the point of connection with the transmission line. The functionality of the STATCOM model is verified by regulating the reactive current flow through it this is useful to generate or absorb reactive power for regulating the line voltage of the bus where the STATCOM is connected. Simila ...
... reactance at the point of connection with the transmission line. The functionality of the STATCOM model is verified by regulating the reactive current flow through it this is useful to generate or absorb reactive power for regulating the line voltage of the bus where the STATCOM is connected. Simila ...
AN-6075 Compact Green-Mode Adapter Using FSQ500L for Low Cost 1. Introduction www.fairchildsemi.com
... shunt regulator (such as the KA431) are typically used to implement the feedback network. Comparing the feedback voltage with the voltage across the Rsense resistor makes it possible to control the switching duty cycle. When the reference pin voltage of the shunt regulator exceeds the internal refer ...
... shunt regulator (such as the KA431) are typically used to implement the feedback network. Comparing the feedback voltage with the voltage across the Rsense resistor makes it possible to control the switching duty cycle. When the reference pin voltage of the shunt regulator exceeds the internal refer ...
Long Range Distance Measurement Using Surge Currents
... Calibration and Display Unit: Calibration plays a very important role when measuring the distance using this method. Though surge currents can produce a large instantaneous intensity such that the longer distances can be measured, the resultant light detected by the photodiode or photo transmitter w ...
... Calibration and Display Unit: Calibration plays a very important role when measuring the distance using this method. Though surge currents can produce a large instantaneous intensity such that the longer distances can be measured, the resultant light detected by the photodiode or photo transmitter w ...
Driver LCA 60 W 24 V one4all SC PRE
... The corridorFUNCTION can be programmed in two different ways. To program the corridorFUNCTION by means of software a DALI-USB interface is needed in combination with a DALI PS. The software can be the masterCONFIGURATOR. To activate the corridorFUNCTION without using software a voltage of 230 V has ...
... The corridorFUNCTION can be programmed in two different ways. To program the corridorFUNCTION by means of software a DALI-USB interface is needed in combination with a DALI PS. The software can be the masterCONFIGURATOR. To activate the corridorFUNCTION without using software a voltage of 230 V has ...
Power and energy meters
... The PM700 series meter offers outstanding quality, versatility, and functionality in a cost-effective, ultra-compact unit. The meter is simple to use and offers a large, bright LCD display for superior readability even in extreme lighting conditions and viewing angles. An ideal replacement for analo ...
... The PM700 series meter offers outstanding quality, versatility, and functionality in a cost-effective, ultra-compact unit. The meter is simple to use and offers a large, bright LCD display for superior readability even in extreme lighting conditions and viewing angles. An ideal replacement for analo ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.