HP 4140B pA Meter / DC Voltage Source
... parameter (START V, STOP V, HOLD TIME...), enter the appropriate data (voltage, time, or ramp rate) and press the ENTER key. Each data entry is stored in memory. The measurement is then made automatically by pushing. the START key, ...
... parameter (START V, STOP V, HOLD TIME...), enter the appropriate data (voltage, time, or ramp rate) and press the ENTER key. Each data entry is stored in memory. The measurement is then made automatically by pushing. the START key, ...
AN439 87C751 fast NiCad charger - Rcl
... the buck and boost converters. As the names imply, the buck converter produces an output lower than its input and the boost converter does the opposite. The transformer isolated versions of the buck and boost circuits are known as the forward and flyback converters. Since the input supply voltage is ...
... the buck and boost converters. As the names imply, the buck converter produces an output lower than its input and the boost converter does the opposite. The transformer isolated versions of the buck and boost circuits are known as the forward and flyback converters. Since the input supply voltage is ...
WISI OH 50 A - WISI Online
... expandable; the WISI COMPACT HEADEND System OH combines all the advantages of an innovative and affordable headend. WISI Compact Headend OH is easy to configure. With up to 14 module slots it offers channel processing for 14 analogue or 28 digital channels in a 3 HU 19“ rack chassis. WISI Compact He ...
... expandable; the WISI COMPACT HEADEND System OH combines all the advantages of an innovative and affordable headend. WISI Compact Headend OH is easy to configure. With up to 14 module slots it offers channel processing for 14 analogue or 28 digital channels in a 3 HU 19“ rack chassis. WISI Compact He ...
PDF (1.45 MB)
... corresponding to the luminous flux rank. Mitsubishi Electric’s design is able to handle up to six different ranks. 3.2 Feed-forward control The LED driver must be designed assuming that the supply voltage varies. Constant current control is generally performed by the feed-back system for the output ...
... corresponding to the luminous flux rank. Mitsubishi Electric’s design is able to handle up to six different ranks. 3.2 Feed-forward control The LED driver must be designed assuming that the supply voltage varies. Constant current control is generally performed by the feed-back system for the output ...
25V, 2A, PNP Bipolar Transistor, SOT-89
... to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant ...
... to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant ...
UDC 621
... accumulated charges flowing into the container inductive-capacitive circuit of the transformer secondary winding gear Tesla (3), creating a bias current, which in contrast to the conduction current does not create resistive thermal energy losses. Voltage and high voltage bias current, single-line gi ...
... accumulated charges flowing into the container inductive-capacitive circuit of the transformer secondary winding gear Tesla (3), creating a bias current, which in contrast to the conduction current does not create resistive thermal energy losses. Voltage and high voltage bias current, single-line gi ...
SMG5 - Fieldpiece Instruments
... the refrigerant and destroy the insulation in the windings of the compressor. With a megger, you can see the degradation over time and may be able to replace the compressor before it catastrophically fails and spews contaminants into the refrigeration system, possibly requiring a much more expensive ...
... the refrigerant and destroy the insulation in the windings of the compressor. With a megger, you can see the degradation over time and may be able to replace the compressor before it catastrophically fails and spews contaminants into the refrigeration system, possibly requiring a much more expensive ...
E-212 - Accuphase
... Tone controls use summing active filters for highest sound quality The tone control circuitry in the E-212 was specially designed with summing active filters. Figure 4 illustrates the operation principle of this circuit. The flat signal is passed straight through, and only when an adjustment is requ ...
... Tone controls use summing active filters for highest sound quality The tone control circuitry in the E-212 was specially designed with summing active filters. Figure 4 illustrates the operation principle of this circuit. The flat signal is passed straight through, and only when an adjustment is requ ...
UcD32MP UcD34MP UcD36MP
... and off through the enable input. The nominal main output voltage will be + and - 18V (@115/230V mains input). The rated power is 70W/5min (according to FTC requirements). The main output is both short and long term over current and short circuit protected. In case of a short term over current condi ...
... and off through the enable input. The nominal main output voltage will be + and - 18V (@115/230V mains input). The rated power is 70W/5min (according to FTC requirements). The main output is both short and long term over current and short circuit protected. In case of a short term over current condi ...
A dual-polarity, bidirectional current-shunt monitor
... from 0.1 W to a larger value. This would increase the INA159 output, but the consequences of the larger voltage drop and higher resistor power dissipation should be evaluated before doing so. The output voltage delivered from the Input Drive: 24 VPP at 1 kHz with 12-Ω load C1 INA159 current-shunt-mo ...
... from 0.1 W to a larger value. This would increase the INA159 output, but the consequences of the larger voltage drop and higher resistor power dissipation should be evaluated before doing so. The output voltage delivered from the Input Drive: 24 VPP at 1 kHz with 12-Ω load C1 INA159 current-shunt-mo ...
AN-2126 LM5046 Based Eighth Brick
... Theory of Operation The Phase-Shifted Full-Bridge (PSFB) topology is a derivative of the classic full-bridge topology. When tuned appropriately the PSFB topology achieves zero voltage switching (ZVS) of the primary FETs while maintaining constant switching frequency. The ZVS feature is highly desira ...
... Theory of Operation The Phase-Shifted Full-Bridge (PSFB) topology is a derivative of the classic full-bridge topology. When tuned appropriately the PSFB topology achieves zero voltage switching (ZVS) of the primary FETs while maintaining constant switching frequency. The ZVS feature is highly desira ...
CN0233: 16位工业、隔离电压电流输出的DAC,同时提供隔离的DC-DC电源 .
... may use the Circuits from the Lab circuits in the design of your product, no other license is granted by implication or otherwise under any patents or other intellectual property by application or use of the Circuits from the Lab circuits. Information furnished by Analog Devices is believed to be ac ...
... may use the Circuits from the Lab circuits in the design of your product, no other license is granted by implication or otherwise under any patents or other intellectual property by application or use of the Circuits from the Lab circuits. Information furnished by Analog Devices is believed to be ac ...
MAX8877/MAX8878 Low-Noise, Low-Dropout, 150mA Linear Regulators with '2982 Pinout __________________General Description
... MAX8878’s input and a 1µF to 10µF capacitor on the output. Larger input capacitor values and lower ESRs provide better supply-noise rejection and line-transient response. Reduce noise and improve load-transient response, stability, and power-supply rejection by using large output capacitors. For sta ...
... MAX8878’s input and a 1µF to 10µF capacitor on the output. Larger input capacitor values and lower ESRs provide better supply-noise rejection and line-transient response. Reduce noise and improve load-transient response, stability, and power-supply rejection by using large output capacitors. For sta ...
Model: BC-12b Switching Type Dual Source Battery Management
... Input power from the solar panel is routed through F2 to the shunt switching charge regulator. Input power from the DC power source is connected through F1 to a series switching charge regulator. The outputs of both regulators are combined in a common cathode Schottky type rectifier. A yellow LED wi ...
... Input power from the solar panel is routed through F2 to the shunt switching charge regulator. Input power from the DC power source is connected through F1 to a series switching charge regulator. The outputs of both regulators are combined in a common cathode Schottky type rectifier. A yellow LED wi ...
Chapter 21 - UET Taxila
... An AC transformer consists of two coils of wire wound around a core of ...
... An AC transformer consists of two coils of wire wound around a core of ...
view the PDF file
... performance more than they help, due to the resonant peaking of their antiquated, non-linear designs. Under certain conditions, these designs can actually add more than 10 dB of noise to the incoming AC line! Worse still, lost digital data, the need to reboot digital presets, or destroyed digital co ...
... performance more than they help, due to the resonant peaking of their antiquated, non-linear designs. Under certain conditions, these designs can actually add more than 10 dB of noise to the incoming AC line! Worse still, lost digital data, the need to reboot digital presets, or destroyed digital co ...
Design and construction of a polygon
... (THD) of the ac mains current. But these topologies require higher rating magnetics, resulting in the enhancement of capital cost. However, this topologies increase the rating of magnetic parts, which finally affects the total cost of the project. In contrast, the autotransformer-based configuration ...
... (THD) of the ac mains current. But these topologies require higher rating magnetics, resulting in the enhancement of capital cost. However, this topologies increase the rating of magnetic parts, which finally affects the total cost of the project. In contrast, the autotransformer-based configuration ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.