• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
E044043336
E044043336

Full-Text PDF
Full-Text PDF

Presentation
Presentation

... 4. A method for commercial losses reduction The carried out analysis of the commercial losses allows to conclude, that one of the ways to reduce these losses (may) can be the reduction of current harmonic levels generated by their sources in the supply network. This can be accomplished in many ways ...
Field Loss Accounted Design and Simulation of a Stand
Field Loss Accounted Design and Simulation of a Stand

... with nominal power of 0.26kWp, Maximum power point (MPP) voltage 36V and current of 0.3A.The open circuit voltage VOC must be calculated for the operating temperature (TC), for each cell it drops by about 2.3mV for each °C over 25°C. ...
Energy Harvesting Device - Ohio State ECE
Energy Harvesting Device - Ohio State ECE

... functional drawing of the TG, which can be seen in figure 3.  The three primary functional elements are  the copper connectors in blue, the p‐type doped Bismuth Telluride metal in dark red and the n‐type  Bismuth Telluride metal in gray. These are all connected in series so that their produced volta ...
Chapter 9 Experiment 7: Electromagnetic Oscillations
Chapter 9 Experiment 7: Electromagnetic Oscillations

... tially if the solenoid had no effect. But the increasing current changes the flux through the solenoid and thereby induces an emf acting on the solenoid itself (referred to as a “back emf”) that slows the rate that the current increases. Once the capacitor has discharged completely, the inductor has ...
chip, the data sheet
chip, the data sheet

... Use the field select pushbutton to select the parameter to adjust, then use up/incr and down/decr pushbuttons to adjust parameter. After five seconds with no switch pressed, display will revert to normal mode. Time seconds value is reset whenever buttons are pressed. To set seconds value to 0, set h ...
Power-generation, Power-electronics and Power
Power-generation, Power-electronics and Power

... energy with little impact on the environment. Governments around the world have signed agreements of reducing their emission of carbon dioxide while the need of energy is increasing. This has led to large programmes to support and subsidise investments in the photovoltaic (PV) area. The most extende ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

AS32300306
AS32300306

AD8079
AD8079

... traces, a space (5 mm min) should be left around the signal lines to minimize coupling. Line lengths on the order of less than 5 mm are recommended. If long runs of coaxial cable are being driven, dispersion and loss must be considered. ...
Lab 3 - Broadband RF Amplifier
Lab 3 - Broadband RF Amplifier

Distributed Voltage Controlled Oscillator
Distributed Voltage Controlled Oscillator

... Proposed Schedule (Continued) ...
3-Anandi
3-Anandi

ADP7118/ADP7142 - Analog Devices
ADP7118/ADP7142 - Analog Devices

... Load Regulation ............................................................................6 ...
Experiment 2K: Kirchhoff`s Rulest
Experiment 2K: Kirchhoff`s Rulest

Wireless Bluetooth Controller For DC Motor
Wireless Bluetooth Controller For DC Motor

EET 251 Unit 2
EET 251 Unit 2

DIY Kit189. 120 Second Vioce Recorder Module
DIY Kit189. 120 Second Vioce Recorder Module

... has much the same specifications as the previous chip but with some extra features that make it easier to use. The ISD1700 series of chips offer a wide range of message durations, ranging from 30 seconds up to 240 seconds depending on the chip. The sampling frequency of each chip can also be adjuste ...
Evaluation Board EVAL-1EDI60I12AF
Evaluation Board EVAL-1EDI60I12AF

... voltage supply monitoring, therefore the user has to ensure, that the voltages remain within the correct range. Voltages exceeding the maximum values may lead to damage of the IGBT drivers and other circuitries. The +5V supply is generated on the board by using the Infineon voltage regulator TLE4264 ...
Tap 128- 2: How many bulbs will a capacitor light
Tap 128- 2: How many bulbs will a capacitor light

MTP1N60E Power MOSFET 1 Amp, 600 Volts
MTP1N60E Power MOSFET 1 Amp, 600 Volts

Varistors: Ideal Solution to Surge Protection
Varistors: Ideal Solution to Surge Protection

mx321 automatic voltage regulator (avr)
mx321 automatic voltage regulator (avr)

Short Circuit
Short Circuit

... 3In, 5In & 10In, depending on B, C & D characteristics Instantaneous/Magnetic Tripping 10 times the rated current; Tripping time must comply with time current curve 100ms is the limit for trip time 6 times In (but not less than 150A) at Rated Voltage Icn 10In or 500A whichever is higher (Tripping th ...
< 1 ... 1260 1261 1262 1263 1264 1265 1266 1267 1268 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report