FMMT593 Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
AN1830
... Refer to Table 5 to understand how it is used. 3.2 SOFTWARE AVERAGING Software averaging is a method used to reduce the effect of erroneous ADC output because of noise or wrong conversion for fixed analog input. As we take the average of several readings, these readings must correspond to the same a ...
... Refer to Table 5 to understand how it is used. 3.2 SOFTWARE AVERAGING Software averaging is a method used to reduce the effect of erroneous ADC output because of noise or wrong conversion for fixed analog input. As we take the average of several readings, these readings must correspond to the same a ...
MAX3301E/MAX3302E USB On-the-Go Transceivers and Charge Pumps General Description Features
... The MAX3301E/MAX3302E integrate a USB OTG transceiver, a VBUS charge pump, a linear regulator, and an I2C-compatible, 2-wire serial interface. An internal level shifter allows the MAX3301E/MAX3302E to interface with +1.65V to +3.6V logic supply voltages. The MAX3301E/MAX3302E’s OTG-compliant charge ...
... The MAX3301E/MAX3302E integrate a USB OTG transceiver, a VBUS charge pump, a linear regulator, and an I2C-compatible, 2-wire serial interface. An internal level shifter allows the MAX3301E/MAX3302E to interface with +1.65V to +3.6V logic supply voltages. The MAX3301E/MAX3302E’s OTG-compliant charge ...
Type CPL and CPH Wide Area Radiant Panels
... WARNING: Hazard of Electric Shock. Heater must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard. 1. All wiring should be done in accordance with the National Electrical Code and with local codes by a qualified person. Use nickel or nickel-clad, copper ...
... WARNING: Hazard of Electric Shock. Heater must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard. 1. All wiring should be done in accordance with the National Electrical Code and with local codes by a qualified person. Use nickel or nickel-clad, copper ...
IQ422 Data Sheet
... address 125 is dynamically created for the period of the SET session. When the PC is removed the sCNC times out and no longer exists on the network. If the sCNC address is configured to be non-zero, the sCNC2 remains on the network map when the SET PC is removed. With the current loop Lan option fit ...
... address 125 is dynamically created for the period of the SET session. When the PC is removed the sCNC times out and no longer exists on the network. If the sCNC address is configured to be non-zero, the sCNC2 remains on the network map when the SET PC is removed. With the current loop Lan option fit ...
Reference Guide The Open Distribution System Simulator
... Neither the name of the Electric Power Research Institute, Inc., nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY Electric Power Research Institute, Inc., "AS IS" ...
... Neither the name of the Electric Power Research Institute, Inc., nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY Electric Power Research Institute, Inc., "AS IS" ...
Sensorless Start-up and Control of Permanent Magnet Synchronous
... With the increasing demand for oil and gas production, oil and gas companies start to step out into deeper waters with continuously increasing pump ratings. Due to these, start-up of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of suffi ...
... With the increasing demand for oil and gas production, oil and gas companies start to step out into deeper waters with continuously increasing pump ratings. Due to these, start-up of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of suffi ...
4.1 Main electrical characteristics
... No refilling of the gas shall be required over this period. Circuit breaker pole units requiring maintenance, inspection or gas refilling will not be accepted. The mechanical and electrical endurance shall ensure at least 10,000 operations. The operation will be abrupt with accumulation of energy an ...
... No refilling of the gas shall be required over this period. Circuit breaker pole units requiring maintenance, inspection or gas refilling will not be accepted. The mechanical and electrical endurance shall ensure at least 10,000 operations. The operation will be abrupt with accumulation of energy an ...
High Power White LED NSPW500BS
... LEDs are damaged by static electricity or not. It is easy to find static-damaged LEDs by light emission test at lower current (below 1mA is recommended). ・ Damaged LEDs will show some unusual characteristics such as leak current remarkably increases, starting forward voltage becomes lower, or the LE ...
... LEDs are damaged by static electricity or not. It is easy to find static-damaged LEDs by light emission test at lower current (below 1mA is recommended). ・ Damaged LEDs will show some unusual characteristics such as leak current remarkably increases, starting forward voltage becomes lower, or the LE ...
Series 71, 72, and 76 Modutrol IV™ Motors
... Disconnect all power supplies before installation. Motors with auxiliary switches can have more than one disconnect. ...
... Disconnect all power supplies before installation. Motors with auxiliary switches can have more than one disconnect. ...
Controlling a Robotic Arm Manipulator with a PLC
... motor controller, a voltage regulator, a control pendent and a bride board circuit). The pre-existing Robotic Arm was designed to work manually using potentiometers and a replacement was made with a PLC. At the beginning, studies were carried out to define the design constraints for finding the best ...
... motor controller, a voltage regulator, a control pendent and a bride board circuit). The pre-existing Robotic Arm was designed to work manually using potentiometers and a replacement was made with a PLC. At the beginning, studies were carried out to define the design constraints for finding the best ...
A Review of ESD Stress Models
... real world charged device event. The second one addresses devices that are inserted in a socket and then charged and discharged in that socket [4]. It is named socketed discharge model (SDM). SDM simulates a device inserted in a socket and charged from a high voltage source and then discharged throu ...
... real world charged device event. The second one addresses devices that are inserted in a socket and then charged and discharged in that socket [4]. It is named socketed discharge model (SDM). SDM simulates a device inserted in a socket and charged from a high voltage source and then discharged throu ...
BDTIC
... Models provided by Infineon are not warranted by Infineon as fully representing all the specifications and operating characteristics of the semiconductor product to which the model relates. The models describe the characteristics of typical devices. In all cases, the current data sheet information f ...
... Models provided by Infineon are not warranted by Infineon as fully representing all the specifications and operating characteristics of the semiconductor product to which the model relates. The models describe the characteristics of typical devices. In all cases, the current data sheet information f ...
product catalog - ASSA ABLOY Door Security Solutions
... The LED extends through the back of the M38 or M68 Magnalock to give visual status of the lock. On locks with the Senstat option, the LED will be green when the lock is powered but not secure and red when the lock is secure. Locks without the Senstat option will only indicate green when powered. Ord ...
... The LED extends through the back of the M38 or M68 Magnalock to give visual status of the lock. On locks with the Senstat option, the LED will be green when the lock is powered but not secure and red when the lock is secure. Locks without the Senstat option will only indicate green when powered. Ord ...
63-2640â08 - Series 71, 72, and 76 Modutrol IV⢠Motors
... Disconnect all power supplies before installation. Motors with auxiliary switches can have more than one disconnect. ...
... Disconnect all power supplies before installation. Motors with auxiliary switches can have more than one disconnect. ...
User Manuals - Fieldpiece Instruments
... cutting, unsoldering, or breaking the circuit. Do not measure resistance (ohms) when circuit is powered. Isolate load by disconnecting from circuit. Disconnect the meter from circuit before turning any inductor off, including motors, transformers, and solenoids. High voltage transients can damage th ...
... cutting, unsoldering, or breaking the circuit. Do not measure resistance (ohms) when circuit is powered. Isolate load by disconnecting from circuit. Disconnect the meter from circuit before turning any inductor off, including motors, transformers, and solenoids. High voltage transients can damage th ...
HEF4104B 1. General description Quad low-to-high voltage translator with 3-state outputs
... (VDD(A)) and the outputs (VDD(B)). VDD(A) must always be less than or equal to VDD(B), even during power turn-on and turn-off. For the permissible operating range of VDD(A) and VDD(B) see Figure 4. Each input protection circuit is terminated between VDD(B) and VSS. This allows the input signals to b ...
... (VDD(A)) and the outputs (VDD(B)). VDD(A) must always be less than or equal to VDD(B), even during power turn-on and turn-off. For the permissible operating range of VDD(A) and VDD(B) see Figure 4. Each input protection circuit is terminated between VDD(B) and VSS. This allows the input signals to b ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.