• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Wind - Feng
Wind - Feng

... • Permanent magnet synchronous generators (PMSG) wind energy conversion system (WECS) using variable speed operation is being used more frequently in wind turbine application. Variable speed systems have several advantages over the traditional method of operating wind turbines, such as the reduction ...
METEOROLOGICAL INSTRUMENTS
METEOROLOGICAL INSTRUMENTS

... Given proper care, the Wind Monitor should provide years of service. The only components likely to need replacement due to normal wear are the precision ball bearings. Only a qualified instrument technician should perform the replacement. If service facilities are not available, return the instrumen ...
Aalborg Universitet Unbalanced Grid Voltage Condition
Aalborg Universitet Unbalanced Grid Voltage Condition

... Although the given proportion of the two wind farms does not represent a real installation, there are a number of existing wind farms which have both PMSG and FSIG in the range of around tens MW. The PMSG-based wind farm consists of 30 1MW PMSG-based wind turbines, and the FSIG-based wind farm consi ...
Seminar Report
Seminar Report

... resources. The wind energy is the fastest growing and most promising renewable energy source among them, but the disadvantage is that the wind power is intermittent and depending upon weather conditions. Steady of thesis is relates to tackle the intermittency problem of wind power by means of a shor ...
Full Text - Journal of American Science
Full Text - Journal of American Science

... Keywords: Power System transients, PSS/E dynamic simulation DFIG of PSS/E WTG user models which have been covered in many publications. Not with standing the provisions of the Egyptian Transmission System Code (the Grid Code), this Wind Farm Grid Connection Code specifies the special requirements fo ...
2014 RA420 PEMC2014 135-Ozsoy
2014 RA420 PEMC2014 135-Ozsoy

... Disturbance of L r and L g Number of pole pairs Stator and grid electrical speed Rotor mechanical speed Mechanical and electrical torque ...
Influence of the Number of Blades on the Mechanical Power
Influence of the Number of Blades on the Mechanical Power

... The generator which is actually designed for 2,5kW wind turbine, is a rare earth permanent magnets synchronous type, with 16 poles for 24 V battery operation. The powerful air gap field and high magnets energy ensure enough breaking torque for fitting the mechanical power curve of the experimented r ...
My Report Title
My Report Title

... Installations smaller than 1MW peak. ...
ABB wind turbine converters Increased turbine output
ABB wind turbine converters Increased turbine output

... grid code requirements. ABB invests significantly into research and development and is active in grid code and power quality working groups supporting power system reliability. ABB engineers provide technical feedback on the feasibility of proposed grid code changes, ensuring the current technology ...
WINDY BOY 5000-US/6000-US/7000-US/8000-US
WINDY BOY 5000-US/6000-US/7000-US/8000-US

... During the startup phase, the small wind energy system is running almost load-free. The Windy Boy only requires the power needed to supply the on-board electronics. If enough on-board power is available, this operating status is indicated by simultaneous lighting-up of the three light-emitting diode ...
Comparison of low voltage AC and DC power grids
Comparison of low voltage AC and DC power grids

... These applications include heating with heat pumps, ventilation, air-conditioning, lighting, photovoltaic power systems and large freezer stations in supermarkets. The all-electric supermarket in [2] is a reference for that using a classical AC grid. The need of power switches for DC grids is also r ...
Using Magnum Energy`s Inverters In AC Coupling
Using Magnum Energy`s Inverters In AC Coupling

... Micro-grids that include energy storage and multiple, on-site power sources, means increased flexibility to provide power. The micro-grid can use stored power or power supplied by the main power distribution network, or even power from another micro-grid that could be connected. These systems can al ...
Power Converters and Control of Renewable Energy Systems
Power Converters and Control of Renewable Energy Systems

... Aalborg University, Institute of Energy Technology, Denmark [email protected], [email protected], [email protected] ...
Using Magnum Energy`s Inverters In AC Coupling Applications
Using Magnum Energy`s Inverters In AC Coupling Applications

... Micro-grids that include energy storage and multiple, on-site power sources, means increased flexibility to provide power. The micro-grid can use stored power or power supplied by the main power distribution network, or even power from another micro-grid that could be connected. These systems can al ...
Aalborg Universitet Moises; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez
Aalborg Universitet Moises; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

... and maximization of batteries lifetime in a microgrid is proposed in [9] and a battery management system of a microgrid for both grid-connected and autonomous modes is presented in [10]. Likewise, an energy management strategy is proposed in [11] for operating PV power plants with ESS in order to en ...
Design for Reliability in Power Electronics in IEEE Member
Design for Reliability in Power Electronics in IEEE Member

... A. Limitation of DFR in Power Electronics Recent research has been devoted to the reliability performance of power electronic components [11]-[12], converters [13]-[15] and systems [16]-[17]. However, the reliability research in the area of power electronics has the following limitations: DFR proces ...
all  other  uses,  in  any ... © 2011 IEEE
all other uses, in any ... © 2011 IEEE

... rotating speed. This will contribute to the active power balance during grid faults and help to extract the maximum power from the wind turbines [2]. Moreover, the converter should have the ability to handle variable fundamental frequency and voltage amplitude of the generator’s output. For the grid ...
HVDC links in AC power system
HVDC links in AC power system

... “Planning for European Electricity Highways to ensure the reliable delivery of renewable electricity and Pan-European market integration” Goal: to develop methods and tools to support supergrid planning, based on future power system scenarios, with options for a pan-European grid ...
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org

... high speed real time synchronized measurement device used for finding health of electrical grid. It is also considered as ULTRA FAST measurement system of grid parameters, and is 100 times faster than present SCADA system. With Synchrophasor data’s electrical utilities can use existing power more ef ...
Aalborg Universitet Generic inertia emulation controller for multi-terminal voltage-source-converter high
Aalborg Universitet Generic inertia emulation controller for multi-terminal voltage-source-converter high

... An island control mode is adapted for the WVSC to establish the offshore network voltage (in contrast to the GSVCs where the voltage of the system being supplied is already established). When the MTDC network is used to connect wind farms, the WVSCs act to set up a “stiff” AC bus with constant volta ...
Impact of Wind Turbine Generating Units on Power System Voltage
Impact of Wind Turbine Generating Units on Power System Voltage

... Abstract-- The operation of a distribution system with a large amount of distributed generation raises a number of issues, for example, voltage profiles change along the network, depending on how much power is produced and consumed at that system level. This paper presents impact of wind turbine gen ...
Senvion MM92 [50Hz/2050kW] Product Description
Senvion MM92 [50Hz/2050kW] Product Description

... In the partial load range, i.e. when the WTG is operated below the rated power, the turbine works at a constant blade pitch and variable speed to exploit the optimum rotor aerodynamics. Within the nominal load area, i.e. when the WTG has reached its maximum rotor speed, it operates with a constant n ...
VOLTAGE FLUCTUATIONS CAUSED BY THE OPERATION OF A
VOLTAGE FLUCTUATIONS CAUSED BY THE OPERATION OF A

... for erection and the rapidly evolving technology. On the other hand, wind energy projects entail high initial capital costs and, in operation, a lack of controllability on the discontinuous or intermittent resource. In spite of these disadvantages, their incorporation is growing steadily, a fact tha ...
Specification sheet (English)
Specification sheet (English)

... in part on the application to which it is being put and in part on the particular circumstances at the site. If the application is very specific, such as monitoring wind speeds on a bridge, then the siting of the head is largely prescribed by use. However, even then, some precautions need to be take ...


... Al- Zawiya University- Faculty of Natural Resources, Libya Department of electrical engineering, SHIATS-Deemed University, Allahabad ...
< 1 2 3 4 5 6 7 8 9 ... 23 >

Intermittent energy source



An intermittent energy source is any source of energy that is not continuously available due to some factor outside direct control. The intermittent source may be quite predictable, for example, tidal power, but cannot be dispatched to meet the demand of a power system. Effective use of intermittent sources in an electric power grid usually relies on using the intermittent sources to displace fuel that would otherwise be consumed by non-renewable power stations, or by storing energy in the form of renewable pumped storage, compressed air or ice, or in batteries, for use when needed, or as electrode heating for district heating schemes.The storage of energy to fill the shortfall intermittency or for emergencies is part of a reliable energy supply. The capacity of a reliable renewable energy supply, can additionally be fulfilled by the use of latency measures and backup or extra infrastructure and technology, using mixed renewables to produce electricity above the intermittent average, which may be utilised to meet regular and unanticipated supply demands.The penetration of intermittent renewables in most power grids is low, but wind generates roughly 16% of electric energy in Spain and Portugal, 15.3% in Ireland, and 7% in Germany. As of 2014 wind provides nearly 40% of the electricity generated in Denmark; 39% in 2014. To operate with this level of penetration, Denmark exports surpluses and imports during shortfalls to and from neighbouring countries, particularly hydroelectric power from Norway, to balance supply with demand. It also uses large numbers of combined heat and power (CHP) stations which can rapidly adjust output.The use of small amounts of intermittent power has little effect on grid operations. Using larger amounts of intermittent power may require upgrades or even a redesign of the grid infrastructure.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report