• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ISA_ISABELLA LX_428000085237_EN.indd
ISA_ISABELLA LX_428000085237_EN.indd

Autonomous distributed temperature sensing for long-term heated
Autonomous distributed temperature sensing for long-term heated

Itelco-RLC-Cap. 01
Itelco-RLC-Cap. 01

Infrared Thermometer using PSoC
Infrared Thermometer using PSoC

BESSEY® Bearing Heaters
BESSEY® Bearing Heaters

Trane Installer`s Guide Air Conditioner/Heat Pump 4TTZ0/4TWZ0
Trane Installer`s Guide Air Conditioner/Heat Pump 4TTZ0/4TWZ0

... Note: 1. * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. 2. YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly. 3. If a 3rd party condensate overf ...
Fundamentals Of HVAC Controls
Fundamentals Of HVAC Controls

MicroMetl - MN Air Online
MicroMetl - MN Air Online

Electric Coils - Price Industries
Electric Coils - Price Industries

... the load, and the hot will be switched – like a light switch. Switched COMMON uses the opposite: hot is wired to the load and the common is switched). 2. Ensure circuit powering the heater has proper capacity. Follow local building codes. 3. The electric duct heater must have an uninterrupted or u ...
REGISTER MY`HW if (l2 desire“?
REGISTER MY`HW if (l2 desire“?

Maxim Design Support Technical Documents Application Notes
Maxim Design Support Technical Documents Application Notes

HEATMASTER HEATMASTER OIL BURNING FURNACE
HEATMASTER HEATMASTER OIL BURNING FURNACE

Chapter 4 Fast Gas Chromatography: Design, construction and evaluation of a fast
Chapter 4 Fast Gas Chromatography: Design, construction and evaluation of a fast

(DOC 0.1 MB)
(DOC 0.1 MB)

... return ported ball shut-off valves with P/T ports. Hose kit options are available in the accessories section of the BST selection software. Kit 1 – Hose kit either 24" or 36" long. Kit 2 – Hose kit with ball valves on the supply and return hoses. Valves shall have P/T ports to facilitate pressure an ...
HSE04WNA Haier Mini Fridge Service Manual
HSE04WNA Haier Mini Fridge Service Manual

Specifying a Solenoid
Specifying a Solenoid

Designing of an office appliance system using temperature.pdf
Designing of an office appliance system using temperature.pdf

HEFAT2008 6 International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics
HEFAT2008 6 International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics

Temperature Measurements
Temperature Measurements

Complex Piping Design Guide
Complex Piping Design Guide

... establish a bill of materials for a heat tracing system. Typically, complex piping is located inside a process unit and consists of relatively short runs of pipe with frequent tees, as well as in-line valves, pumps and related process equipment that also requires heat tracing. Circuit lengths can ra ...
Manual - Oven Industries
Manual - Oven Industries

HVAC/R Systems - vortex.com.br
HVAC/R Systems - vortex.com.br

... Servicing and maintaining refrigeration, air conditioning, and heat pump systems can be a tricky business—unless you have the right tools. Measurements must be accurate, even when taken in changing or harsh environments. Speed and ease-of-use are important, too. Often a single-point-in-time measurem ...
Type CPL and CPH Wide Area Radiant Panels
Type CPL and CPH Wide Area Radiant Panels

Table I: Pulse Magnet Systems for E951 Targetry Experiment
Table I: Pulse Magnet Systems for E951 Targetry Experiment

System 350 A350E Electronic Cooling Control Product
System 350 A350E Electronic Cooling Control Product

< 1 2 3 4 5 6 7 ... 13 >

Thermostat



A thermostat is a component of a HVAC control system which senses the temperature of a system so that the system's temperature is maintained near a desired setpoint. The thermostat does this by switching heating or cooling devices on or off, or regulating the flow of a heat transfer fluid as needed, to maintain the correct temperature.A thermostat may be a control unit for a heating or cooling system or a component part of or air conditioner. Thermostats can be constructed in many ways and may use a variety of sensors to measure the temperature. The output of the sensor then controls the heating or cooling apparatus. A thermostat may switch on and off at temperatures either side of the setpoint. This prevents equipment damage from frequent switching. Thermostats are also used in many household appliances. A thermostat is an instance of a ""bang-bang controller"" as the heating or cooling system output is not proportional to the difference between actual temperature and the set temperature; the equipment runs at full capacity until the set temperature is reached, then shuts off. Increasing the difference between the thermostat setting and the desired temperature therefore does not shorten the time to achieve the desired temperature.The term is derived from the Greek words θερμός thermos, ""comfortable"" and στατός statos, ""climate controlled"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report