• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Digital Input/Output Interface Card "OPC-DIO"
Digital Input/Output Interface Card "OPC-DIO"

... (1) All types of monitor data (output frequency, output current, etc) set with function code o21 can be output as 8-bit binary output signals. (2) When function code o21 is set to 99, all output terminals can be used as general-purpose output terminals (inverter unit Y terminal or equivalent). Funct ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... to convert higher system rail voltages to low voltages at close proximity to the load. This allows for lower conduction loss through the system rails since currents will be significantly lower than the device load current. Thus, DC-DC “step-down” converters are required for this application. As impl ...
chapter_10
chapter_10

... more unconnected logic gates. • A more recently available type of gate array, known as a field programmable gate array. ...
Busbar Trunking System
Busbar Trunking System

... feeding loads upto 400A with standard plug-in boxes. The system has provision of 4 Plug-in outlets per meter, which can be fitted quickly and provide total flexibility for any change in distribution layout at a later stage. The system has been designed especially for installations and projects where ...
1999 Product Catalog
1999 Product Catalog

... Source Component: ...
HX5000 ASIC Platform S150 (150 nm) ASICs
HX5000 ASIC Platform S150 (150 nm) ASICs

... counts exceeding 8 million usable gates. This is achieved using a fully planarized 6-layer metal process. HX5000 is designed for use over the full military temperature range while operating in harsh radiation environments. The S150 technology is designed to withstand extremely high levels of Total D ...
A Review Paper on Icing and Methods to De
A Review Paper on Icing and Methods to De

... power flow without adding any deicer. After the ice disaster of 1998 in north eastern America, Hydro-Québec developed a de-icing strategy for 120~315kV lines. A computer program has been developed to simulate the ice buildup on conductors and melting the ice using the heat generated by the currents ...
Tech Note MSP to Aromat(NAiS) FP0 Revision: 4.9 Following are
Tech Note MSP to Aromat(NAiS) FP0 Revision: 4.9 Following are

... b) Rung comments are plagued with bugs especially when deleting and inserting lines. I lost the comments several times and gave up trying to provide meaningful comments. They have been use mostly to mark the sections of the program. They will probably be lost or corrupted when you copy the driver to ...
Half Bridge Gate Driver
Half Bridge Gate Driver

... - High side only gate drivers - Built-in UVLO function for VBS - Built-in Shunt regulator for VDD and VBS - Allowable – Vs swing to – 9.8V @VBS = 15V - Source/Sink current 4.0A/4.0A - Pin compatible with FAN7371,IRS21850, and IRS21851 - Package : 8-SOP ...
PE3501 - Peregrine Semiconductor
PE3501 - Peregrine Semiconductor

... or in other applications intended to support or sustain life, or in any application in which the failure of the Peregrine product could create a situation in which personal injury or death might occur. Peregrine assumes no liability for damages, including consequential or incidental damages, arising ...
Measuring Parasitic Capacitance and Inductance Using TDR
Measuring Parasitic Capacitance and Inductance Using TDR

... wave that gets reflected from the discontinuity caused by the via is observed. The amount of “excess” capacitance caused by the via can be calculated by integrating and scaling the reflected waveform. Using this method, the measured value of capacitance is the correct value of capacitance to be used ...
RF2367
RF2367

EC2357-VLSI DESIGN LABORATORY LABORATORY MANUAL FOR SIXTH SEMESTER B.E (ECE)
EC2357-VLSI DESIGN LABORATORY LABORATORY MANUAL FOR SIXTH SEMESTER B.E (ECE)

... Many ISE processes produce summary reports which enable you to check information about your design after each process is run. Detailed reports are available from the Processes for Source window. You can also view summary information and access most often-utilized reports in the Design Summary. 1. Cl ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... which is easier to design, implement and control. But, they do not provide satisfactory performance in case of large disturbances and for different operating points, since the power system is non-linear [10]. The Fuzzy logic is an effective technique with the capability of tolerating uncertainty and ...
Lecture 12-power-examples
Lecture 12-power-examples

... Activity factor: probability a that a node switches 0→1 Define probability Pi that a node is “1” Probability that a node is “0” is then Pi = 1-Pi ai = Pi * Pi Completely random data has P = 0.5 and a = 0.25 Data is often not completely random Data propagating through ANDs and ORs has lower activity ...
W10_Slides
W10_Slides

... Long line length, line resistance and line capacitance govern the circuit speed. Cooling the room temperature to 77K reduces the resistivity by an order of magnitude. At higher frequencies, Ghz and above the skin effect has to be taken into account. CONCORDIA VLSI DESIGN LAB ...
A 24-GHz High-Isolation CMOS T/R Switch with
A 24-GHz High-Isolation CMOS T/R Switch with

... isolation between Rx and Tx port is 34.3 dB. The measured input 1-dB compression point and third order intercept point are 18 dBm and 28.5 dBm , respectively, as shown in Fig. 7 (e) and Fig. 7 (f). These results have good power handling, and this can be increased by replacing low voltage control wit ...
Impedance Matching Networks Applied to RF Power Transistors
Impedance Matching Networks Applied to RF Power Transistors

EMI EMC Considerations for Energy Meters Application Note
EMI EMC Considerations for Energy Meters Application Note

... the energy meter in high-frequency (HF) electromagnetic fields. High-frequency field generators are also used to tamper with energy meters. One of the most common results of these high-frequency fields is that it causes the meter to hang. Electrical standards require a meter to be fully functional a ...
linn aktiv modules
linn aktiv modules

... amplifiers and loudspeakers in your hi-fi system to work together in an ideal way. The active filters give greater accuracy and lower distortion than conventional passive crossovers. The power amplifier is connected directly to the drive units so that none of the amplifier's power is lost. The drive ...
Analytical Design of Permanent-Magnet Traction-Drive Motors Chunting Chris Mi
Analytical Design of Permanent-Magnet Traction-Drive Motors Chunting Chris Mi

... has a very low Curie temperature and high temperature sensitivity. It is often necessary to increase the size of magnets to avoid demagnetization at high temperatures and high currents. On the other hand, it is advantageous to use as little PM material as possible in order to reduce the cost without ...
TG1000 and TG2000 low cost 10MHz and 20MHz DDS function
TG1000 and TG2000 low cost 10MHz and 20MHz DDS function

... Ultimately what matters in a function generator is the quality of the output signal. The TG1000/2000 maintains the TTi reputation for high signal quality at all frequencies and all levels. The waveform capture opposite shows just how much difference that can make ! The 'scope display opposite was ca ...
Precision Full-Wave Rectifier, Dual-Supply
Precision Full-Wave Rectifier, Dual-Supply

J. Hu, A.D. Sagneri, J.M. Rivas, Y. Han, S.M. Davis, and D.J. Perreault, “High-Frequency Resonant SEPIC Converter with Wide Input and Output Voltage Ranges,   2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 1397 – 1406
J. Hu, A.D. Sagneri, J.M. Rivas, Y. Han, S.M. Davis, and D.J. Perreault, “High-Frequency Resonant SEPIC Converter with Wide Input and Output Voltage Ranges,   2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 1397 – 1406

... the operating frequency is calculated as the complex ratio ZEQV = VR,1 /IIN , where VR,1 is the fundamental of VR . This equivalent impedance can be used in place of the rectifier for designing the resonant inverter, assuming that the majority of the output power delivered to the load is transferred ...
SRAM pres.
SRAM pres.

... This puts the contents of all 2M bit cells in that row onto the 2M column lines. Each column line consists of two bit complementary bit lines. Use a sense amplifier in order to remove any signal loss (because of capacitance of bit line). Column decoder selects one of these bit lines and gates them i ...
< 1 ... 52 53 54 55 56 57 58 59 60 ... 174 >

Transmission line loudspeaker

A transmission line loudspeaker is a loudspeaker enclosure design (topology) that uses an acoustic transmission line within the cabinet, compared to the simpler enclosures used by sealed (closed) or ported (bass reflex) designs. Instead of reverberating in a fairly simple damped enclosure, sound from the back of the bass speaker is directed into a long (generally folded) damped pathway within the speaker enclosure, which allows far greater control and use of speaker energy, and the resulting sound.Inside a transmission line loudspeaker, is a (usually folded) pathway into which the sound is directed. The pathway is often covered with varying types and depths of absorbent material, may vary in size or taper, and may be open or closed at its far end. Used correctly, such a design ensures that undesired resonances and energies, which would otherwise cause undesirable auditory effects, are instead selectively absorbed or reduced (""damped"") due to the effects of the duct, or alternatively only emerge from the open end in phase with the sound radiated from the front of the driver, enhancing the output level (""sensitivity"") at low frequencies. The transmission line acts as an acoustic waveguide, and the padding both reduces reflection and resonance, and also slows the speed of sound within the cabinet to allow for better tuning.Transmission line loudspeakers designs are more complex to implement, making mass production difficult, but their advantages have led to acclaim for a number of manufacturers such as IMF, TDL, PMC, KVART & BØLGE and the like. As a rule, transmission line speakers tend to have exceptionally high fidelity low frequency response far below that of a typical speaker or subwoofer, into the infrasonic (British company TDL's studio monitor range from the 1990s quoted their frequency responses as starting from as low as 7 Hz depending upon model) at sensitivity 96 dB, without need for a separate enclosure or driver. Acoustically, TL speakers roll off slower at low frequencies and provide better driver control than standard reflex cabinet designs, are less sensitive to positioning, and tend to create a very spacious soundstage. Modern TL speakers were described in a 2000 review as ""match[ing] reflex cabinet designs in every respect, but with an extra octave of bass, lower LF distortion and a frequency balance which is more independent of listening level"".Although more complex to design and tune, and not as easy to analyze and calculate as other designs, the transmission line design is valued by several smaller manufacturers, as it avoids many of the major disadvantages of other loudspeaker designs. In particular, the basic parameters and equations describing sealed and reflex designs are fairly well understood, the range of options involved in a transmission line design mean that the general design can be somewhat calculated but final transmission line tuning requires considerable attention and is less easy to automate.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report