SERVAL
... has factory-set default configuration settings and is fully operable upon installation. Using the COACH configuration tool, the controller can be configured with project-specific settings. Using the CARE engineering tool, the controller can be configured by means of an LNS plug-in. A variety of COMM ...
... has factory-set default configuration settings and is fully operable upon installation. Using the COACH configuration tool, the controller can be configured with project-specific settings. Using the CARE engineering tool, the controller can be configured by means of an LNS plug-in. A variety of COMM ...
UNIVERSAL MOTOR - Home
... experiences no torque during current reversal, but the average torque is sufficient to turn the motor as if it were connected to a DC power supply. ...
... experiences no torque during current reversal, but the average torque is sufficient to turn the motor as if it were connected to a DC power supply. ...
Aalborg Universitet Dynamic Consensus Algorithm based Distributed Unbalance Compensation in Islanded Microgrids
... The power flow issue in unbalanced system has been clarified in [14], the 3-phase current can be taken as a superposition of instantaneous symmetrical sequence currents (positive-IP, negative-IN, zero-IZ). Positive sequence power can be shared by using droop control and virtual impedance, zero seque ...
... The power flow issue in unbalanced system has been clarified in [14], the 3-phase current can be taken as a superposition of instantaneous symmetrical sequence currents (positive-IP, negative-IN, zero-IZ). Positive sequence power can be shared by using droop control and virtual impedance, zero seque ...
EO24881888
... required by the power stage. This implies that the closed loop output voltage should be independent of either the supply voltage or the load current and should be determined only by the reference voltage. A nonlinear control strategy can be applied to the buck-type dc-to-dc converter to realize the ...
... required by the power stage. This implies that the closed loop output voltage should be independent of either the supply voltage or the load current and should be determined only by the reference voltage. A nonlinear control strategy can be applied to the buck-type dc-to-dc converter to realize the ...
KE2417381744
... In order to compare the presented control scheme and some existing techniques, the following three cases have been studied. T1 Balanced control case: It is the classical control approach, which does not take into account the possibility of unbalanced voltage disturbances. It is described I number of ...
... In order to compare the presented control scheme and some existing techniques, the following three cases have been studied. T1 Balanced control case: It is the classical control approach, which does not take into account the possibility of unbalanced voltage disturbances. It is described I number of ...
FPGA-Based Control for Electric Vehicle and Hybrid Electric
... toolflow creates optimized FPGA implementations, with fMAX and logic usage similar to hand-coded HDL. In addition, the tool provides the option to implement in either fixed point or floating point, something that is generally not feasible using a HDL approach. This frees the designer from numerical ...
... toolflow creates optimized FPGA implementations, with fMAX and logic usage similar to hand-coded HDL. In addition, the tool provides the option to implement in either fixed point or floating point, something that is generally not feasible using a HDL approach. This frees the designer from numerical ...
OUTPATIENT & OFFSITE FACILITY DESIGN GUIDELINE SUMMARY
... Future capacity in outpatient facilities is relaxed to require only 10% (versus 25% in Inpatient). Outside air design conditions utilized for outpatient facilities allow the ASHRAE 1% design criteria (88°F DB/72°F WB) versus the ASHRAE 0.4% criteria we require for Inpatient facility design (90°F DB/ ...
... Future capacity in outpatient facilities is relaxed to require only 10% (versus 25% in Inpatient). Outside air design conditions utilized for outpatient facilities allow the ASHRAE 1% design criteria (88°F DB/72°F WB) versus the ASHRAE 0.4% criteria we require for Inpatient facility design (90°F DB/ ...
Spectrometer Electronics
... It can control most of the popular spectroscopy image sensors with JETI‘s wide range of available signal conditioning boards. PE60 is stackable with additional boards to provide additional communication interfaces like Ethernet & RS485 and encoders or TEC control electronics for precise temperature ...
... It can control most of the popular spectroscopy image sensors with JETI‘s wide range of available signal conditioning boards. PE60 is stackable with additional boards to provide additional communication interfaces like Ethernet & RS485 and encoders or TEC control electronics for precise temperature ...
SB0800 Octal Valves and Pump Controller System on Chip
... solution is suitable for loads with high inrush current and allows driving to high frequency (up to ...
... solution is suitable for loads with high inrush current and allows driving to high frequency (up to ...
Kit Instructions - Jameco Electronics
... 2- Only two ports of the microcontroller to change the rotation direction of two small electric motors. 3- One port to control speed of rotation (PWM control). The digital pins PD4, PD3 of microcontroller Atmega 328, control the rotation direction of motors, and the pin PD6, control the speed of rot ...
... 2- Only two ports of the microcontroller to change the rotation direction of two small electric motors. 3- One port to control speed of rotation (PWM control). The digital pins PD4, PD3 of microcontroller Atmega 328, control the rotation direction of motors, and the pin PD6, control the speed of rot ...
Resilient control systems
In our modern society, computerized or digital control systems have been used to reliably automate many of the industrial operations that we take for granted, from the power plant to the automobiles we drive. However, the complexity of these systems and how the designers integrate them, the roles and responsibilities of the humans that interact with the systems, and the cyber security of these highly networked systems has led to a new paradigm in research philosophy for next generation control systems. Resilient Control Systems consider all of these elements and those disciplines that contribute to a more effective design, such as cognitive psychology, computer science, and control engineering to develop interdisciplinary solutions. These solutions consider such things such as how to tailor the control system operating displays to best enable the user to make an accurate and reproducible response, how to design in cyber security protections such that the system defends itself from attack by changing its behaviors, and how to better integrate widely distributed computer control systems to prevent cascading failures that result in disruptions to critical industrial operations. In the context of cyber-physical systems, resilient control systems are an aspect that focuses on the unique interdependencies of a control system, as compared to information technology computer systems and networks, due to its importance in operating our critical industrial operations.