• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Journal of Environmental Science, Computer Science and
Journal of Environmental Science, Computer Science and

... angle control of converter design. The thyristor of converter receive conduction the firing pulse either mode of continuous or discontinuous operation. To simplify single phase dual converter, two of these full converter are connected back to back as shown in figure 2. The system will provide four q ...
Model Predictive Controller-based, Single Phase Pulse Width
Model Predictive Controller-based, Single Phase Pulse Width

Traction Permanent Magnet Synchronous Motor Torque Control with
Traction Permanent Magnet Synchronous Motor Torque Control with

2. Flux Weakening of PMSM
2. Flux Weakening of PMSM

Control of Parallel Connected Three-Phase PWM Converters
Control of Parallel Connected Three-Phase PWM Converters

Speed Control With Low Armature Loss for Very Small Sensorless
Speed Control With Low Armature Loss for Very Small Sensorless

... vary. Motor 2 uses forcedconvection cooling. ...
what is servo motor and drive
what is servo motor and drive

Conditions for Running the DTC
Conditions for Running the DTC

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Any small-scale localized station with its own resources, generations and loads and definable limitations qualifies as a microgrid. Microgrids can be intended as standby power or to booster the main power grid during periods of heavy demand and for reducing costs and enhancing reliability. The modul ...
Aalborg Universitet Secondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids
Aalborg Universitet Secondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids

... thus needing voltage balancing controllers or large dc-link capacitors [8]. In addition, this solution suffers from poor dc voltage utilization. The four-leg topology, due to the extra degree of freedom provided by the fourth leg, the three phases become independent. In addition, a 3-D space vector ...
NMX120-3, On/Off, Floating Point, Non-Spring Return
NMX120-3, On/Off, Floating Point, Non-Spring Return

WellPilot® Controllers for Rod Pump Optimization
WellPilot® Controllers for Rod Pump Optimization

... The brains behind every WellPilot rod-pump control system. The powerful WellPilot RPC gathers data from the well through surface load and position sensors and uses the MEJ calculation engine to calculate downhole data to determine pump fillage and fluid level for each stroke. In fixed-speed applicat ...
Summit 3208 GLD - Hotronic
Summit 3208 GLD - Hotronic

Aucun titre de diapositive - Small Hydro
Aucun titre de diapositive - Small Hydro

... • New equipment has been installed where necessary. • Modern electronic equipment has been hooked to the old and new equipment to properly monitor them. • The old small hydro plant is now remotely controlled by computer rather than by an on site staff. ...
Healthcare Solutions Custom
Healthcare Solutions Custom

... know they can be beneficial practically everywhere. Linking critical areas to pharmacies and labs, or linking building to building, we can connect them all. As a world leader in pneumatic tube system technology, Aerocom’s custom design capabilities and extensive installation experience can provide c ...
Aalborg Universitet Coordinated Power Control Strategy based on Primary-Frequency-Signaling for Islanded Microgrids
Aalborg Universitet Coordinated Power Control Strategy based on Primary-Frequency-Signaling for Islanded Microgrids

... achieve coordinated control is supervisory control with communication link [6-7]. This algorithm utilizes a higher level controller to manage the power flow of each unit using physical communication setup, which may increase cost and complexity for microgrids. This paper adopted an interesting way o ...
Document
Document

... • A “yield” function is used to give up control to the next process, so that when control is returned execution starts at the instruction following the “yield” function • An “abort” function is used to give up control to the next process, so that when control is returned execution starts at the begi ...
NX-M700 Series Master Control Panel
NX-M700 Series Master Control Panel

ACS Control with opto-Triac
ACS Control with opto-Triac

Download: 32.31.00_15501K_16501K
Download: 32.31.00_15501K_16501K

... B. Actuator mounting post to be either 1. Set in ground at least two feet beneath the applicable frost line with concrete mixed prior to pour totaling in weight to no less than fifty percent (50%) greater than that of the driven gate leaf and not to be less than five hundred (500) pounds 2. Anchored ...


Direct Acting Float Switch - Global Engineered Products, LLC.
Direct Acting Float Switch - Global Engineered Products, LLC.

... Float switch body shall be constructed of Teflon®-coated, 20 gauge, 316 stainless steel housing measuring not less than 51/2" in diameter. A long life, high reliability, potted SPST magnetic reed switch rated for not less than 100 VA at up to 250 Volts shall be mounted inside the float and connected ...
Science-Engineering-Technology Standards K-12 k
Science-Engineering-Technology Standards K-12 k

PPS - Institut Mihajlo Pupin
PPS - Institut Mihajlo Pupin

... although EVA current is pulsating  Change of vibratory width is due to change of phase angle (by decrease of phase angle, the effective voltage and coil current increase  This is caused by increase of the oscillation amplitude of LCE too, which is created by stronger impulse of exciting force;in o ...
PP BorgWarner OEM 2012_GB_FIN.indd
PP BorgWarner OEM 2012_GB_FIN.indd

... extremely low electrical resistance at low temperatures. A low resistance means a high current flow and with it a high output, almost 100% of which is converted into heat. If the temperature rises, this effect is inverted, i.e. less heat is released. Below a certain critical temperature, a point is ...
< 1 ... 55 56 57 58 59 60 61 62 63 ... 122 >

Resilient control systems



In our modern society, computerized or digital control systems have been used to reliably automate many of the industrial operations that we take for granted, from the power plant to the automobiles we drive. However, the complexity of these systems and how the designers integrate them, the roles and responsibilities of the humans that interact with the systems, and the cyber security of these highly networked systems has led to a new paradigm in research philosophy for next generation control systems. Resilient Control Systems consider all of these elements and those disciplines that contribute to a more effective design, such as cognitive psychology, computer science, and control engineering to develop interdisciplinary solutions. These solutions consider such things such as how to tailor the control system operating displays to best enable the user to make an accurate and reproducible response, how to design in cyber security protections such that the system defends itself from attack by changing its behaviors, and how to better integrate widely distributed computer control systems to prevent cascading failures that result in disruptions to critical industrial operations. In the context of cyber-physical systems, resilient control systems are an aspect that focuses on the unique interdependencies of a control system, as compared to information technology computer systems and networks, due to its importance in operating our critical industrial operations.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report