Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Telephone Dialer Summit 3208GLD The Summit 3208GLD allows for up to four different telephone numbers to be programmed into the system. Up to 16 digits can be programmed for each telephone number. An additional number can be used in conjunction with the remote programming call back feature. The Summit 3208GLD supports either pulse or DTMF dialing. Its built-in communicator for central station communication supports Contact ID, SIA and most major protocols. These implement either event or zone oriented event code messages, which allows the built-in communicator to interface with a wider selection of central stations. All events can be programmed to transmit an event code message to the central station. A mu l t i t u d e o f p o s s i b i l i t i e s Follow Me Feature with User acknowledge The follow me feature lets users program a telephone number at which the system can notify them should an alarm occur. The user acknowledges that the message has been received by pressing a key on their telephone. Message Routing Message routing can be programmed for single or multiple central station notification, enabling notification of up to four central stations. Listen-in Feature Certain models of the Summit 3208GLD control panel have a built-in listenin feature for alarm verification. Should an alarm be activated, the control panel will contact the central station, transmit an alarm message and then enter the Listen-in option for a defined period of time. The Summit 3208GLD is the next generation of Electronics Line control Zone Descriptors panels and communicators. Our control panel reaches new heights by A standard, definable library of 60 zone descriptors is available for the LCD keypad display. Additionally, four zone descriptors can be programmed by the installer for customization of individual installations. bringing with it a combination of technologically advanced features that ensure the highest standard of security with ultimate flexibility to adapt to a multitude of applications. The Summit 3208GLD provides Latch Key Feature the end user with a reliable and convenient control panel that surpasses The latch key feature is used when you want to verify the departure or arrival of individuals from the area protected by your Summit 3208GLD security system. For example, this feature is ideal for parents who want to know whether their child has arrived home safely. expectations. The advantage of this system is that it can be modulated to suit specific Technical Specifications Current Consumption 3108 LCD Keypad 3106 LED Keypad 3508 Zone Expander Module 3528 Wireless Zone Expander Module 3402 Output Relay Module 3407 Output Relay Module 3417 Transistor Module Operating Temperature Dimensions da r d s I n s ti t uti on Is r a T he of St an el SI Sales in the UK: Unit 7, Leviss Trading Estate Station Road, Stechford Birmingham B33 9AE Tel: (+44-121) 789-8111 Fax: (+44-121) 789-8055 E-mail: [email protected] ua Q www.electronics-line.com Sales in the USA: 1640 Range St. Boulder, CO 80301 Tel: (800) 683-6835 Fax: (303) 938-8062 E-mail: [email protected] m ISO 9002 International Sales: Electronics Line 3000 Ltd. 2 Granit St. Kiryat Arieh Industrial Zone POB 3253 Petah Tikva 49130 Israel Tel: (+972-3) 918-1333 Fax: (+972-3) 922-0831 E-mail: [email protected] Electronics Line. Create the perfect security system by making the AC: 15Vac, 30Va transformer Battery backup 12Vdc, 6.5Ah or 7Ah (UL requirement) Approximately 130mA 20mA without backlight, 60mA with backlight 20mA without backlight, 70mA with backlight 10mA 10mA 15mA all relays deactivated, 30mA per activated relay 15mA all relays deactivated, 30mA per activated relay 10mA all relays deactivated, 725mA all relays transistors (drawing a max. 100mA each) 00 to 600C (320 to 1400F) 30.5cm x 30.5cm x 10.2cm (12" x 12" x 4") li t y A s su re d Fi r Sales in France: Zi 61 Rue Du Marche Rollay 94500 Champigny Sur Marne Tel: (+33-1) 45.16.19.20 Fax: (+33-1) 45.16.19.29 E-mail: [email protected] system adapt to your needs. Key Features of the Summit 3208GLD: ZP0017B Power Input requirements through the use of various accessories offered by 8 on-board zones (expandable to 32) True partitions with up to 4 sub-systems Common zone for partitioned systems Expanded event log (100 events) Built-in communicator for central station communication Remote and keypad programming Answering machine override Wide variety of arming possibilities Distress key alarms for Fire, Police and Emergency 15 User codes with 15 authorization levels each Master code enabling arming/disarming of all sub-systems Supports up to 8 supervised keypads Bell output supervision (UL listed models only) Follow me with user acknowledge Message routing Listen-in feature Full library of zone descriptors Programmable relay outputs Opening and closing windows Latch key feature System Partitioning 3108 LCD Keypad 3106 LED Keypad The 3108 LCD keypad is the ideal keypad for any environment. The two-row liquid crystal display walks you through operations. From its easy operation to its attractive design, the 3108 keypad is the perfect companion to your Summit 3208GLD control panel. The 3106 LED is a low cost and easy to use keypad suitable for simpler installations or installations with multiple keypads. 3911 Remote Programming Device and Software Electronics Line's remote programming software offers a full range of programming capabilities. Uploading and downloading of programming parameters, log reviewing and operation commands can be performed from a PC either from a remote location or on-site using the "Off-hook" feature. The toll saver feature, remote programmer callback makes contacting the system cost-effective and efficient and increases the level of security. Answering Machine Override The answering machine override feature enables remote programming when the control panel is connected to a telephone line shared with an answering machine or fax. 3722 Transformer The system can be partitioned into a maximum of four independent sub-systems with individual account numbers, keypads, user codes and relays assigned exclusively for each sub-system. This enables one control panel to protect up to four different areas such as storefronts, homes, businesses, garages etc. Common Zone Common zones are generally used in partitioned systems where, for example, different office departments, which are classified as separate zones, are linked by a shared or common corridor. An alarm will be generated from a common zone (corridor) only if all the sub-systems are armed. Expanded Event Log An optional 15 Vac, CE approved transformer is available with the Summit 3208GLD 3417 Seven Output Transistor Module The 3417 seven output transistor module adds 7 programmable, open collector transistor outputs to the Summit 3208GLD control panel. These can be used for several applications such as status indication and additional bell outputs. Relay Modules Choose between the 3402 two relay module and the 3407 seven relay module that add 2 and 7 Form-C, dry contact relays respectively. Both have 24 different programmable operating modes offering a wide range of practical applications. The event log stores information regarding alarms and system trouble. The events can be classified into tamper, bell, keypad, distress key activation and zone activation. The Summit 3208GLD includes a fully partitioned, expanded event log, which records the last 100 events the system has undergone. Additionally, the new event log shows the events in reverse chronological order i.e. the most recent event is shown first. Wide Variety of Arming Possibilities Two-Way Audio Module The two-way audio module provides the control panel with fully programmable, two-way audio communication for alarm verification. The module is microprocessor controlled and allows the central station a number of remote command capabilities such as high-gain talk and high-gain listen-in. UHF/VHF Transmitters There are various methods of arming the Summit 3208GLD that enable the user to arm the system in whichever way suits their specific circumstances. The methods are: ● Away arming - arms the system, securing the protected environment. ● Stay arming - arms the perimeter zones while allowing the user free movement within the protected environment. ● Forced arming - arms the system with zones still open on theassumption that these zones will be secured by the end of the exit delay. ● One key arming - allows Stay and Away arming of the system without a user code. ● Immediate arming - allows the partition to be armed without an entry or exit delay ● Keyswitch arming - allows for the manual arming and disarming of the system by the turn of a key The transmitters allow the Summit 3208GLD to connect directly with Electronics Line's IGP 8000 wireless central station. Zone Expander Modules The 3508 zone expander module adds 8 hardwire zones while the 3528 wireless zone expander module adds 8 wireless zones to the Summit 3208GLD. Install them in the 3208GLD cabinet or mount them in their own standalone metal box, which is available with an optional tamper switch. Choose the alternative that best suits your requirements. Distress Key Alarms The Summit 3208GLD keypad comes equipped with three emergency distress keys for notification purposes in the e v e n t o f f i r e , p o l i c e o r m e d i c a l e m e rg e n c i e s . Duress Code Battery Cut-Off Module Voice Message Module The unit is connected between the control panel and the battery and serves as a monitor for the dc input voltage into the control panel. The unit begins to work when the panel's dc input voltage falls below approximately 10.2Vdc. Dc input of below this mark results in the unit disconnecting dc input to the control panel. Used in conjuction with the "follow me" feature, the vocal message module allows the user to record up to six personalized messages that will report the type of alarm generated, This replaces the conventional system where combinations of beeps are used to identify the type of alarm generated. MasterLink Supervised Wireless Zone Expander EL-2530 The EL-2530, which incorporates MaserLink's SecuriCodeTM technology, is designed to interface with the Summit 3208GLD control panel. It supports up to 64 wireless transmitters, is capable of indentifying a large number of events and adds up to 32 wireless zones. The duress code is designed for situations where the user is being forced to operate the system. This code, while performing the selected operation, sends a silent alarm to the central station. Bell Output Supervision - UL Listed models only In the event of a siren failure, the keypad will sound a constant chime alerting the user to the problem.