Telephone Dialer
Summit
3208GLD
The Summit 3208GLD allows for up to four different telephone numbers
to be programmed into the system. Up to 16 digits can be programmed
for each telephone number. An additional number can be used in conjunction
with the remote programming call back feature. The Summit 3208GLD
supports either pulse or DTMF dialing. Its built-in communicator for central
station communication supports Contact ID, SIA and most major protocols.
These implement either event or zone oriented event code messages, which
allows the built-in communicator to interface with a wider selection of central
stations. All events can be programmed to transmit an event code message
to the central station.
A mu l t i t u d e o f p o s s i b i l i t i e s
Follow Me Feature with User acknowledge
The follow me feature lets users program a telephone number at which
the system can notify them should an alarm occur. The user acknowledges
that the message has been received by pressing a key on their telephone.
Message Routing
Message routing can be programmed for single or multiple central station
notification, enabling notification of up to four central stations.
Listen-in Feature
Certain models of the Summit 3208GLD control panel have a built-in listenin feature for alarm verification. Should an alarm be activated, the control
panel will contact the central station, transmit an alarm message and then
enter the Listen-in option for a defined period of time.
The Summit 3208GLD is the next generation of Electronics Line control
Zone Descriptors
panels and communicators. Our control panel reaches new heights by
A standard, definable library of 60 zone descriptors is available for the LCD
keypad display. Additionally, four zone descriptors can be programmed
by the installer for customization of individual installations.
bringing with it a combination of technologically advanced features
that ensure the highest standard of security with ultimate flexibility
to adapt to a multitude of applications. The Summit 3208GLD provides
Latch Key Feature
the end user with a reliable and convenient control panel that surpasses
The latch key feature is used when you want to verify the departure or arrival
of individuals from the area protected by your Summit 3208GLD security
system. For example, this feature is ideal for parents who want to know
whether their child has arrived home safely.
expectations.
The advantage of this system is that it can be modulated to suit specific
Technical Specifications
Current Consumption
3108 LCD Keypad
3106 LED Keypad
3508 Zone Expander Module
3528 Wireless Zone Expander Module
3402 Output Relay Module
3407 Output Relay Module
3417 Transistor Module
Operating Temperature
Dimensions
da
r d s I n s ti t uti
on
Is r a
T he
of
St
an
el
SI
Sales in the UK:
Unit 7, Leviss Trading Estate
Station Road, Stechford
Birmingham B33 9AE
Tel: (+44-121) 789-8111
Fax: (+44-121) 789-8055
E-mail: [email protected]
ua
Q
www.electronics-line.com
Sales in the USA:
1640 Range St.
Boulder, CO 80301
Tel: (800) 683-6835
Fax: (303) 938-8062
E-mail: [email protected]
m
ISO 9002
International Sales:
Electronics Line 3000 Ltd.
2 Granit St.
Kiryat Arieh Industrial Zone
POB 3253
Petah Tikva 49130 Israel
Tel: (+972-3) 918-1333
Fax: (+972-3) 922-0831
E-mail: [email protected]
Electronics Line. Create the perfect security system by making the
AC: 15Vac, 30Va transformer
Battery backup 12Vdc, 6.5Ah or 7Ah (UL requirement)
Approximately 130mA
20mA without backlight, 60mA with backlight
20mA without backlight, 70mA with backlight
10mA
10mA
15mA all relays deactivated, 30mA per activated relay
15mA all relays deactivated, 30mA per activated relay
10mA all relays deactivated, 725mA all relays transistors (drawing a max. 100mA each)
00 to 600C (320 to 1400F)
30.5cm x 30.5cm x 10.2cm (12" x 12" x 4")
li t y
A s su re d
Fi
r
Sales in France:
Zi 61 Rue Du Marche Rollay
94500 Champigny Sur Marne
Tel: (+33-1) 45.16.19.20
Fax: (+33-1) 45.16.19.29
E-mail: [email protected]
system adapt to your needs.
Key Features of the Summit 3208GLD:
ZP0017B
Power Input
requirements through the use of various accessories offered by
8 on-board zones (expandable to 32)
True partitions with up to 4 sub-systems
Common zone for partitioned systems
Expanded event log (100 events)
Built-in communicator for central station
communication
Remote and keypad programming
Answering machine override
Wide variety of arming possibilities
Distress key alarms for Fire, Police and Emergency
15 User codes with 15 authorization levels each
Master code enabling arming/disarming of all
sub-systems
Supports up to 8 supervised keypads
Bell output supervision (UL listed models only)
Follow me with user acknowledge
Message routing
Listen-in feature
Full library of zone descriptors
Programmable relay outputs
Opening and closing windows
Latch key feature
System Partitioning
3108 LCD Keypad
3106 LED Keypad
The 3108 LCD keypad is the ideal keypad for
any environment. The two-row liquid crystal
display walks you through operations. From
its easy operation to its attractive design, the
3108 keypad is the perfect companion to
your Summit 3208GLD control panel.
The 3106 LED is a low cost and
easy to use keypad suitable for
simpler installations or installations
with multiple keypads.
3911 Remote Programming Device
and Software
Electronics Line's remote programming software
offers a full range of programming capabilities.
Uploading and downloading of programming
parameters, log reviewing and operation
commands can be performed from a PC either
from a remote location or on-site using the
"Off-hook" feature. The toll saver feature, remote
programmer callback makes contacting the
system cost-effective and efficient and increases
the level of security.
Answering Machine Override
The answering machine override feature enables remote programming when
the control panel is connected to a telephone line shared with an answering
machine or fax.
3722 Transformer
The system can be partitioned into a maximum of four
independent sub-systems with individual account numbers,
keypads, user codes and relays assigned exclusively for
each sub-system. This enables one control panel to protect
up to four different areas such as storefronts, homes,
businesses, garages etc.
Common Zone
Common zones are generally used in partitioned systems
where, for example, different office departments, which are
classified as separate zones, are linked by a shared or
common corridor. An alarm will be generated from a common
zone (corridor) only if all the sub-systems are armed.
Expanded Event Log
An optional 15 Vac, CE approved transformer is available with the
Summit 3208GLD
3417 Seven Output Transistor Module
The 3417 seven output transistor module adds 7
programmable, open collector transistor outputs
to the Summit 3208GLD control panel. These can
be used for several applications such as status
indication and additional bell outputs.
Relay Modules
Choose between the 3402 two relay module and the 3407 seven relay module
that add 2 and 7 Form-C, dry contact relays respectively. Both have 24 different
programmable operating modes offering a wide range of practical applications.
The event log stores information regarding alarms and
system trouble. The events can be classified into tamper,
bell, keypad, distress key activation and zone activation.
The Summit 3208GLD includes a fully partitioned, expanded
event log, which records the last 100 events the system
has undergone. Additionally, the new event log shows the
events in reverse chronological order i.e. the most recent
event is shown first.
Wide Variety of Arming Possibilities
Two-Way Audio Module
The two-way audio module provides the control panel with fully
programmable, two-way audio communication for alarm verification.
The module is microprocessor controlled and allows the central station
a number of remote command capabilities such as high-gain talk and
high-gain listen-in.
UHF/VHF Transmitters
There are various methods of arming the Summit 3208GLD
that enable the user to arm the system in whichever way suits
their specific circumstances. The methods are:
● Away arming - arms the system, securing the protected
environment.
● Stay arming - arms the perimeter zones while allowing the
user free movement within the protected environment.
● Forced arming - arms the system with zones still open on
theassumption that these zones will be secured by the end
of the exit delay.
● One key arming - allows Stay and Away arming of the system
without a user code.
● Immediate arming - allows the partition to be armed without
an entry or exit delay
● Keyswitch arming - allows for the manual arming and
disarming of the system by the turn of a key
The transmitters allow the Summit 3208GLD to
connect directly with Electronics Line's IGP 8000
wireless central station.
Zone Expander Modules
The 3508 zone expander module adds 8 hardwire zones while the 3528 wireless
zone expander module adds 8 wireless zones to the Summit 3208GLD. Install
them in the 3208GLD cabinet or mount them in their own standalone metal box,
which is available with an optional tamper switch. Choose the alternative that
best suits your requirements.
Distress Key Alarms
The Summit 3208GLD keypad comes equipped with three
emergency distress keys for notification purposes in the
e v e n t o f f i r e , p o l i c e o r m e d i c a l e m e rg e n c i e s .
Duress Code
Battery Cut-Off Module
Voice Message Module
The unit is connected between the control panel
and the battery and serves as a monitor for the dc
input voltage into the control panel. The unit begins
to work when the panel's dc input voltage falls below
approximately 10.2Vdc. Dc input of below this mark
results in the unit disconnecting dc input to the
control panel.
Used in conjuction with the "follow me" feature, the vocal message
module allows the user to record up to six personalized messages
that will report the type of alarm generated, This replaces the
conventional system where combinations of beeps are used to identify
the type of alarm generated.
MasterLink Supervised Wireless Zone
Expander EL-2530
The EL-2530, which incorporates MaserLink's
SecuriCodeTM technology, is designed to interface
with the Summit 3208GLD control panel. It supports
up to 64 wireless transmitters, is capable of
indentifying a large number of events and adds
up to 32 wireless zones.
The duress code is designed for situations where the user
is being forced to operate the system. This code, while
performing the selected operation, sends a silent alarm to
the central station.
Bell Output Supervision - UL Listed
models only
In the event of a siren failure, the keypad will sound a constant
chime alerting the user to the problem.