• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Performance Analysis of Double Inverter Fed Wound Rotor Induction
Performance Analysis of Double Inverter Fed Wound Rotor Induction

... technique and fuzzy logic. This system has been designed to have two controllers, one Fuzzy based controller for stator and another one PID based for rotor. Such a mixed implementation leads to a more effective control design objectives such as steady state and transient characteristics of the close ...
Introduction
Introduction

... Any I/O pins not being used should be configured as an output and driven to a logic low state. Alternately, a 1K-10K ohm resistor connected between VSS and the unused pin would drive the output low. VDD and VSS are attached to the board and will be connected to the power supply at a voltage level ac ...
PDF
PDF

... the internal storage of instructions for implementing specific functions such as logic, sequencing, timing, counting, and arithmetic to control, through digital or analog input/output modules, various types of machines or processes. Programmable controllers were originally designed for General Motor ...
Notes 6
Notes 6

... – Separate start relay and run relays – Start relay energized first, then after time delay, start relay is de-energized and run relay is energized ...
Power-Synchronization Control of Grid-Connected Voltage
Power-Synchronization Control of Grid-Connected Voltage

... resonance that is typically present. This can interfere with the fast inner current control loop, thereby limiting the VSC control performance [7], [11]. The other one has to do with the phase-locked loop (PLL). In almost all VSCs connected to ac systems, a PLL is used to obtain an accurate synchron ...
Motor control and sensor testing
Motor control and sensor testing

Automatic Voltage Control
Automatic Voltage Control

Boiler Controller
Boiler Controller

Troubleshooting an EC Fan (Non Modbus) in a
Troubleshooting an EC Fan (Non Modbus) in a

INDCONTANLPRDFL, Analog Products for the Industrial Market
INDCONTANLPRDFL, Analog Products for the Industrial Market

... 16-ouput low-side switches able to control loads up to 2.5 A, daisy chainable SPI with or without parallel inputs mode for PWM capability on all outputs Fully integrated octal, quad valves and pump controller system on chip solutions with SPI, PWM up to 5 kHz (5.0 A), real-time valve current regulat ...
AF16-30-10-14
AF16-30-10-14

... between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... ...
PZ210E User Manual E-462 Piezo Amplifier Release: 1.1.0 Date: 20
PZ210E User Manual E-462 Piezo Amplifier Release: 1.1.0 Date: 20

... CURRENTS which can cause death or injury! Take special care if connecting products from other manufactures. ...
review paper on controlling the speed of dc motor
review paper on controlling the speed of dc motor

... motor and the motor which is excited by some dc source to produce mechanical energy is then known as DC motor. The advantages of using DC motors over AC motors are explained below. ...
Form5446.--A (Sprinter Dashmount Switch).qxd
Form5446.--A (Sprinter Dashmount Switch).qxd

... Connect Red Ignition wire to black/pink wire at fuse box behind driver side lower dash panel Fuse Box ...
simulation of matrix converter-fed permanent magnet synchronous
simulation of matrix converter-fed permanent magnet synchronous

... Figure 1. Structure of the matrix converter. In high-performance permanent-magnet synchronous motor drive systems, features such as not being affected from parameter changes and quick speed response to the speed demand are required [8-9]. The main principal of the vector control is based on decoupli ...
Comparison of SVPWM and SPWM Techniques for Back to Back
Comparison of SVPWM and SPWM Techniques for Back to Back

... induction machine and permanent magnet synchronous machine are seen as promising elements for energy conversion. In all cases back to back (BTB) arrangement based on power electronics is required to take advantage of the benefits [9-11]. BTB converter is formed by two identical voltage source conver ...
Multi-agent approach to emergency control of power system
Multi-agent approach to emergency control of power system

... •Discrete control devices are different protection relays, under load tap changers, etc. •Currently both continuous and discrete control devices substantially use local signals only and do not coordinate their actions with each other. ...
Voltage Controlled Oscillator(VCO) using 555 timer IC.
Voltage Controlled Oscillator(VCO) using 555 timer IC.

... A VCO normally just sits there outputting a variety of waveforms, at a frequency determined by the combination of the "coarse" and "fine tune" adjustments on the control panel. The keyboard controller's CV output is added to the internal VCO control voltage to determine the final pitch output by th ...
HVAC Electric Duct Heaters Electrical Construction
HVAC Electric Duct Heaters Electrical Construction

Model 548 Solid State DC Load Switch
Model 548 Solid State DC Load Switch

SMC24Analog System Controller Key Features: Specifications:
SMC24Analog System Controller Key Features: Specifications:

Slow Control - ALICE TPC Front End Electronics
Slow Control - ALICE TPC Front End Electronics

... In normal mode (monitor the status of the cards) Safety procedures in case of problems ...
Stepper Motors - WordPress.com
Stepper Motors - WordPress.com

Manual WB2.
Manual WB2.

... The controller converts current signals from lambda sensor to lambda number (λ). The lambda number value is converted to two customizable modifiable analogue inputs with range from 0.03V to 5 V. The values can also be transmitted using two data lines. The lines are UART (RS232) and CAN (High speed). ...
Stall Motor Controll - North River Railway
Stall Motor Controll - North River Railway

... • Prototyping boards, Vectorboard, Keyboard and Perf board are all names for the same type of board used in electronics for prototyping circuits. • It is made of materials such as phenolic or epoxy glass and is about 1/16” (.062) thick. • Hole patterns vary greatly but a ...
< 1 ... 89 90 91 92 93 94 95 96 97 ... 140 >

Control theory



Control theory is an interdisciplinary branch of engineering and mathematics that deals with the behavior of dynamical systems with inputs, and how their behavior is modified by feedback. The usual objective of control theory is to control a system, often called the plant, so its output follows a desired control signal, called the reference, which may be a fixed or changing value. To do this a controller is designed, which monitors the output and compares it with the reference. The difference between actual and desired output, called the error signal, is applied as feedback to the input of the system, to bring the actual output closer to the reference. Some topics studied in control theory are stability (whether the output will converge to the reference value or oscillate about it), controllability and observability.Extensive use is usually made of a diagrammatic style known as the block diagram. The transfer function, also known as the system function or network function, is a mathematical representation of the relation between the input and output based on the differential equations describing the system.Although a major application of control theory is in control systems engineering, which deals with the design of process control systems for industry, other applications range far beyond this. As the general theory of feedback systems, control theory is useful wherever feedback occurs. A few examples are in physiology, electronics, climate modeling, machine design, ecosystems, navigation, neural networks, predator-prey interaction, gene expression, and production theory.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report